• Title/Summary/Keyword: E-J power

Search Result 823, Processing Time 1.835 seconds

Evaluation of J$_lc$ and T$_mat$ of aged 1Cr-1Mo-0.25V steel at elevated temperature (시효열화시킨 1Cr-1Mo-0.25V 강의 고온에서의 J$_lc$ 및 T$_mat$ 의 평가)

  • 윤기봉;윤석호;서창민;남승훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2860-2870
    • /
    • 1994
  • When crack are detected in aged turbine rotors of power plants, information on fracture resistance of the aged material at operating temperature is needed for determination of critical loading condition and residual life of the turbine. In this study, fracture toughness (J$_lc$) and tearing modulus(T$_mat$) of virgin and thermally degraded 1Cr-1Mo-0.25V steel, which is one of the most widely used rotor steels, were measured at 538.deg. C according to ASTM E813 and ASTM E1152, respectively. Five kinds of specimen with different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C.$ It was observed that J$_lc$ and T$_mat$ value decreased as the degradation level increased. Analysis of microstructures using a scanning electron microscope showed that the decrement of J$_lc$ is related to segregation of impurities at grain boundaries. It was also verified that the DC electric potential drop method is accurate and reliable for crack length monitoring at elevated temperature.

A Study on Enhancing the Total Transfer Capability from Voltage Stability Point of View Using UPFC (IPLAN을 이용한 UPFC 적용 전력시스템의 전압 안정도 측면에서의 융통전력 향상 효과 분석)

  • Lee, S.J.;Lee, B.H.;Kim, J.H.;Kim, Y.H.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.151-153
    • /
    • 2002
  • Using UPFC(Unified Power Flow Controlled), it is possible to control three parameters(voltage, impedance, and phase angle). The UPFC can generate or absorb reactive power rapidly so as to enhance the transient and voltage stability and also influence the power flow. In this paper, the effects of application of the UPFC to the power system are analyzed from a viewpoint of improving the total transfer capability by enhancing voltage stability. The IPLAN, which is a high level language used with PSS/E program, is employed for evaluating the total transfer capability from a f-V curve.

  • PDF

Design of Robust Adaptive Controller for the Improvement in Performance (응답 특성이 향상된 강인한 적응 제어기 설계)

  • Choi, J.B.;Byun, S.H.;Lee, J.H.;Jeong, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.667-671
    • /
    • 1997
  • 본 논문에서는 적응제어계통의 강인성을 향상시키기 위한 새로운 알고리즘을 제시한다. 이 적응 알고리즘은 외란의 영향을 상쇄시키고 Lyapunov 도함수 $V{\le}0$가 되도록 한다. 그 결과로서 외란이 존재하는 경우만 아니라 이상적인 경우에도 출력오차가 0에 수렴한다. 또한 컴퓨터 시뮬레이션과 DC 서보 전동기의 위치제어 실험을 통하여 $e_1$ 변형법과 실험결과를 비교함으로써 제안한 알고리즘의 타당성을 보여준다.

  • PDF

Series-parallel resonant converter using a contactless power supply for the efficiency improvement (효율 개선을 위한 직${\cdot}$병렬 공진컨버터 적용 비접촉 전원)

  • Kong Y.S.;Lee H.K.;Kim E.S.;Cho J.G.;Kim J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • To improve the efficiency characteristics in the resonant converter using the contact-less power supply with the large air-gap and the long primary winding, this paper suggests the three-level series-parallel resonant converter(SPRC). The voltage gain characteristics of the proposed converter have the unit gain in a resonance frequency point of the series and parallel, and input voltage and current in the primary of SPRC are always In phase for the all equivalent load resistance because of the parallel resonant tank of the high impedance. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental prototype.

  • PDF

Structural Performance of the Cast-in-place Anchor in Cracked Concrete used in Power Plant Facilities (균열 콘크리트에 매립된 발전설비 현장설치용 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jung, Woo-young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.120-128
    • /
    • 2019
  • It is very important to verify the seismic performance and stability of the power plant fixture in the domestic power plant, because earthquakes have increased in frequency around the world which resulted in the frequent occurrence of power plant damage caused by the failure of electric power facilities. In this study, through the on-site inspection of power plant fixation unit installed in domestic power plants, we carried out structural performance evaluation of the fixation unit anchor bolts installed on the concrete slabs. The field survey showed M12 J hook anchor bolts were used. Anchor bolt pullout and shear performance evaluation were performed based on ASTM E 488-96 standard. Moreover, artificial crack with the width of 0.5 mm was applied during the experiment based on ATM355.4 and ETAG 001. The comparison of M12 J hook anchor bolt pullout and shear test result to design value required in domestic and international design standard, show a satisfactory result. M12 J hook anchor pullout and shear performance was found to be about 35% and 7%, respectively, higher than the required design value.

Soft Switching Single Stage AC-DC Full Bridge Boost Converter Using Non-Dissipative Snubber Circuits (무손실 스너버적용 소프트 스위칭 Single Stage AC-DC Full Bridge Boost 캔버터)

  • Kim, E.S.;Kim, T.J.;Joe, K.Y.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1989-1992
    • /
    • 1997
  • A new soft switching single stage AC-DC full bridge boost converter with unit input power factor and isolated output is presented. Due to using of the non-dissipative snubber in the primary side, a single stage high-power factor isolated full bridge boost converter has a significant reduction of switching losses in main switching devices and output rectifiers of the primary and secondary side, respectively. The non-dissipative snubber adopted in this study is consisted of a snubber capacitor C. and a snubber inductor $L_r$, a fast recovery snubber diode $D_r$, a commutation diode $D_p$. This paper presents the complete operating principles, theoretical analysis and simulation results.

  • PDF

Development of Hardware for Power System Stabilizer(PSS) (발전기 제어계통 안정화 장치용 하드웨어 개발)

  • Kim, C.K.;Park, M.K.;Kim, J.M.;Kweon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.131-133
    • /
    • 2001
  • The basic function of a Power-System Stabilizer(PSS) is to add damping to the generator rotor oscillations by controlling its excitation using auxiliary stabilizing signals. To provide damping. the stabilizer must produce a component of electrical torque in phase with the rotor speed deviations. This paper introduces the hardware specifications and various functions of microprocessor (TMS320C32)-based digital PSS to provide the damping torque.

  • PDF

Tracking Control of Maximum Power Point using Step-up Chopper (체승 Chopper를 이용한 최대 출력점 추적 제어)

  • Chung, Y.T.;Han, K.H.;Jang, K.H.;Kwon, H.;Kang, S.W.;Lee, S.H.;Kim, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.323-325
    • /
    • 1990
  • In this paper, a new method to track the maximum power point is presented. The proposed scheme achieves the maximum power the step-up chopper, which tracks the maximum power point by sensing only the actual current from the photovoltaic array. Also it adopts the protect ion circuit to protect the battery system against the overvoltage and overvoltage by utilizing hysterisis characteristic.

  • PDF