• Title/Summary/Keyword: E-J power

Search Result 823, Processing Time 0.029 seconds

Test and Fabrication of the 1MJ Superconducting Magnetic Energy Storage System (1MJ급 초전도에너지저장시스템 제작 및 평가)

  • Kim, H.J.;Seong, K.C.;Cho, J.W.;Kim, S.W.;Bae, J.H.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.685-687
    • /
    • 2002
  • For several decades researches and developments on superconducting magnetic energy storage (SMES) system have been done for efficient electric power management. Korea Electrotechnology Research Institute(KERI) have developed of a 1MJ. 300kVA SMES System for improving power quality in sensitive electric loads. We developed the code for design of a SMES magnet. which could find the parameters of the SMES magnet having minimum amount of superconductors for the same stored energy. and designed the 1MJ SMES magnet by using it. This paper describes the design. fabrication and experimental results for the SMES magnet. cryostat, HTS current lead and power converter.

  • PDF

Full-Color AMOLED with RGBW Pixel Pattern

  • Amold, A.D.;Hatwar, T.K.;Hettel, M.V.;Kane, P.J.;Miller, M.E.;Murdoch, M.J.;Spindler, J.P.;Slyke, S.A. Van;Mameno, K.;Nishikawa, R.;Omura, T.;Matsumoto, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.808-811
    • /
    • 2004
  • A full-color AMOLED display with an RGBW color filter pattern has been fabricated. Displays with this format require about $^1/_2$ the power of analogous RGB displays. RGBW and RGB 2.16inch diagonal displays with average power consumptions of 180 mW and 340 mW, respectively, are demonstrated for a set of standard digital still camera images at a luminance of 100 cd/$m^2$. In both cases, a white-emitting AMOLED is used as the light source. The higher efficiency of the RGBW format results because a large fraction of a typical image can be represented as white, and the white sub-pixel in an RGBW AMOLED display is highly efficient because of the absence of any color filter. RGBW and RGB AMOLED displays have the same color gamut and, aside from the power consumption difference, are indistinguishable.

  • PDF

A Single Stage Boost Input Type Resonant AC-DC Converter with High Power Factor (고역률의 단일단 부스트 입력방식의 공진형 AC-DC 컨버터)

  • Yeon J.E.;Jeong J.B.;Kim H.J,
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.66-68
    • /
    • 2003
  • This paper proposes the single stage boost input type resonant AC-DC converter. Proposed converter uses the resonance between leakage inductance of the transformer and resonance capacitance. And it obtains high power factor more than 98$\%$ through continuous current mode pulse width modulation. To verify the validity of the proposed converter, operation principle In the steady state is analyzed and experimental results are presented.

  • PDF

Research on Operational Characteristics of Power Distribution System with Distributed Resources Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 분산전원의 계통연계 운전 특성 분석)

  • Jang, S.I.;Park, J.S.;Kim, K.H.;Park, J.K.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.113-115
    • /
    • 2000
  • This paper presents the modeling and simulation studies, using PSCAD/EMTDC, for the operation of DR(Distributed Resources) connected to the power system. In this study, we model the DR operated in parallel with the distribution system and simulate several operation modes of DR. Finally, the transient characteristics of the operation modes are evaluated with IEEE Standard 519-1992. IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems

  • PDF

Development of 3 phase Power Flow calculation algorithm in distribution Power Systems using Symmetrical Component (Symmetrical Components를 이용한 배전계통 3상 조류 계산 알고리즘 개발)

  • Choi, J.H.;Jang, S.I.;Kim, K.H.;Park, J.K.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.147-149
    • /
    • 2000
  • This paper describes a power flow method for distribution systems, applying the method of symmetrical component to back/forward sweep method. The proposed algorithm is effective for unbalanced radial distribution system, with process of distributed resource(PQ & PV node), AVR(Auto Voltage Regulator), shunt capacitor. This proposed method compared conventional back/forward sweep method with the using three phase unbalanced distribution systems with 34 nodes.

  • PDF

Performance Analysis of Grid-Connected PCS for PV System by Field Demonstration Test

  • So J.H.;Jung Y.S.;Yu G.J.;Jung M.W.;Kang G.H.;Choi J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.516-519
    • /
    • 2003
  • 3kW photovoltaic (PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center (FDTC) of Korea. As climatic and irradiation conditions are varied, the performance characteristics of PV system are collected and analyzed in data acquisition system. From these results, the performances of gird-connected power conditioning system (PCS) fur PV system have been evaluated and analyzed. Furthermore, performance indices of grid-connected PCS e.g. output power, efficiency, loss factor, and the other index at the site are reviewed.

  • PDF

Trends in Ultra Low Power Intelligent Edge Semiconductor Technology (초저전력 엣지 지능형반도체 기술 동향)

  • Oh, K.I.;Kim, S.E.;Bae, Y.H.;Park, S.M.;Lee, J.J.;Kang, S.W.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.6
    • /
    • pp.24-33
    • /
    • 2018
  • In the age of IoT, in which everything is connected to a network, there have been increases in the amount of data traffic, latency, and the risk of personal privacy breaches that conventional cloud computing technology cannot cope with. The idea of edge computing has emerged as a solution to these issues, and furthermore, the concept of ultra-low power edge intelligent semiconductors in which the IoT device itself performs intelligent decisions and processes data has been established. The key elements of this function are an intelligent semiconductor based on artificial intelligence, connectivity for the efficient connection of neurons and synapses, and a large-scale spiking neural network simulation framework for the performance prediction of a neural network. This paper covers the current trends in ultra-low power edge intelligent semiconductors including issues regarding their technology and application.

Evaluation of 300kJ Capacitor Bank Module for High Current Pulse Shaping (대전류 펄스 성형을 위한 300kJ급 커패시터뱅크 모듈의 특성 평가)

  • Hwang, Dong-Won;Lee, Hong-Sik;Jin, Yun-Sik;Cho, Chu-Hyun;Kim, Jong-Soo;Rim, Geun.Hee;Park, Won-Zoo;Kim, Jin-Sung;Jung, Jae-Won;Chu, Jeung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2086-2088
    • /
    • 2000
  • Key elements of in the development Electro-Thermal-Chemical propulsion (ETC) are high current pulse shaping, switching and storage bank device with high energy density 300kJ pulse power capacitor bank module for ETC application is designed and fabricated. The tested result are described.

  • PDF

The mechanical characteristics of 345kV XLPE cable (345kV XLPE 2000$mm^2$ 케이블의 기계적특성 고찰)

  • Nam, S.H.;Baek, J.H.;Heo, H.D.;Lee, S.H.;Kim, C.M.;Lee, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1688-1690
    • /
    • 2001
  • The mechanical characteristics of XLPE cable is basic to the installation design. Especially, snake and offset design require accurate coefficient of linear expansion($\alpha$), Young's modulus(E) and bending stiffness(El) of the cable. In this paper, $\alpha$, E and El of 345kV XLPE cable was measured by experimental setup, and verified by measuring axial tension and lateral displacement in snake installation.

  • PDF

Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities (비균열 콘크리트에 매립된 발전설비 정착부 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jong, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.250-258
    • /
    • 2019
  • The seismic performance and stability of operating facilities installed in domestic power plants need to be verified because of the increased incidence of earthquakes resulting in power plant damage due to the overturning failure of electric operating facilities. In this study, a structural performance evaluation of the anchor bolts constructed to setup the operating facilities on concrete slabs was carried out through an on-site inspection of power plants, called Daechung-Dam. M10 J hook and M12 J hook anchor bolts were installed in the field unit. According to the ASTM E 488-96 specifications, anchor bolt pullout and shear tests were carried out and compared with the anchor-bolt design standards. The results from the tension and shear pullout tests showed that the M10 and M12 J hook anchor bolts had higher performance than the required design load. Thus, they were found to be safe enough. Nevertheless, more research in the field of analytical study will be needed in the near future.