• Title/Summary/Keyword: E test

Search Result 8,680, Processing Time 0.041 seconds

Distribution of Vancomycin-resistant Enterococci Isolates Using a ChromID VRE Agar

  • Lee, Hyun;Yoon, In-Seon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.1
    • /
    • pp.1-4
    • /
    • 2013
  • Vancomycin-resistant enterococci (VRE) have emerged as important healthcare-associated infection since last two decades. ChromID VRE agar (cIDVA) is useful for VRE rectal swab screening. We investigated all VRE were isolated on the cIDVA. A total of 363 rectal swabs of 85 patients to test VRE screening were inoculated into bile-esculin (B-E) broth with $6{\mu}g/mL$ vancomycin. After 24 hours incubation, we subcultured B-E broths were changed to black onto cIDVA. All isolates were identified by the MICROSCAN and VITEK2. The vanA gene and vancomycin minimal inhibition concentration (MIC) were detected by PCR and E-test respectively. 277 E. faecium (84.7%), 16 E. faecalis (4.9%), 25 E. avium (7.6%), 8 E. gallinarum (2.4%) and 1 E. raffinosus (0.3%) were isolated. 10.3% of VRE detected on cIDVA were other than E. faecium and E. faecalis that presented various color from colorless to pale violet. All isolates contained vanA and vancomycin MIC were > $256{\mu}g/mL$. VRE isolates other than E. faecium and E. faecalis should be objective to the contact precautions for healthcare-associated infection control if they possess vanA gene. Due to emerging enterococci carrying vanA such as E. avium, E. gallinarum, and E. raffinosus, VRE surveillance should be expanded to all isolates on chromogenic agar.

  • PDF

A Study on the Test & Evaluation Process of Civil Aircraft for Compliance (적합성 입증을 위한 민항기 시험평가 절차 연구)

  • Kim, Kwang Hae;Choi, Nag Sun;Koh, Dae Woo
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The Test and Evaluation (T&E) process is an integral part of the Systems Engineering Process. The purpose of Test and Evaluation (T&E) in a system development is to identify the areas of risk to be reduced or eliminated. In this study, when develop aircraft of Civil Aviation with development experience of Military Aircraft, it is that establish Test and Evaluation process. Test and Evaluation for KC-100 small aircraft development can divide to certification test and development test. Certification test is proved compliance about Korea Airworthiness standard (KAS Part 23), through Development Test verify required performance of aircraft. These Test and Evaluation Process is more efficient and optimized.

  • PDF

ADVANCED TEST REACTOR TESTING EXPERIENCE - PAST, PRESENT AND FUTURE

  • Marshall Frances M.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.411-416
    • /
    • 2006
  • The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is one of the world's premier test reactors for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The physical configuration of the ATR, a 4-leaf clover shape, allows the reactor to be operated at different power levels in the comer 'lobes' to allow for different testing conditions for multiple simultaneous experiments. The combination of high flux (maximum thermal neutron fluxes of 1E15 neutrons per square centimeter per second and maximum fast [E>1.0 MeV] neutron fluxes of 5E14 neutrons per square centimeter per second) and large test volumes (up to 122 cm long and 12.7 cm diameter) provide unique testing opportunities. The current experiments in the ATR are for a variety of test sponsors - US government, foreign governments, private researchers, and commercial companies needing neutron irradiation services. There are three basic types of test configurations in the ATR. The simplest configuration is the sealed static capsule, which places the capsule in direct contact with the primary coolant. The next level of experiment complexity is an instrumented lead experiment, which allows for active control of experiment conditions during the irradiation. The most complex experiment is the pressurized water loop, in which the test sample can be subjected to the exact environment of a pressurized water reactor. For future research, some ATR modifications and enhancements are currently planned. This paper provides more details on some of the ATR capabilities, key design features, experiments, and future plans.

Effect of Red and Infrared LED Light Therapy on Allergic Rhinitis (알레르기 비염 환자에서 적색 및 근적외선 LED 광선 치료 효과)

  • Park, Eal Whan
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.125-131
    • /
    • 2019
  • As a non-invasive method for alleviating allergic rhinitis, there has been a recent ongoing research in the treatment of light from light emitting diodes (LEDs) and lasers. A total of 15 subjects diagnosed with allergic rhinitis were selected for this study. Red and near infrared light emitted from LEDs with wavelengths of 660nm and 940nm were illuminated three times daily (three minutes per cycle) for a total of two weeks. The degree of nasal congestion, runny nose, sneezing and nasal itching was evaluated by questionnaires before and after the test. Also, the serum IgE (Immunoglobulin E) was measured and compared before and after the test. As a result, the total score of symptoms of allergic rhinitis was decreased by 67% after the test (P<0.01). The level of IgE was decreased by 17% after the test (P<0.05). In conclusion, the non-invasive LED phototherapy method using red and near-infrared LED light was effective in alleviating symptoms of allergic rhinitis. There were no adverse effects or complications reported during and after the test.

Study on Relationship between constitution medicine and Prostaglandin E2 in Blood (사상인(四象人) 체질(體質)과 혈중(血中) Prostaglandin E2치(値)와의 관계(關係)에 관(關)한 연구(硏究))

  • Kim, Jong-Weon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.9 no.2
    • /
    • pp.245-261
    • /
    • 1997
  • The investigation were carried out the 37 patient with cerebrovascular accidents who had been treated in Oriental Medical Hospital in Kyung Hee University and in KangNam Uy Lim, and the 10 examinees who had been worked in Medical Hospital in Kyung Hee University. The consitution which had discriminated by survey, which had discriminated by study on the morphological diagrammings, which had discriminated by the result of the impatient of hospital on a dosage of constitutial prescription. The Prostaglandin E2 in blood for 47 persons (37 patients & 10 examinees) was measured. The following results were obtained. 1.In the constitution which had discriminated by survey, in the value of Prostaglandin E2 in bood of ammong four constitutiens didn,t showed significant differance. 2.In the constitution which had discriminated by study on the morphological diagrammings, in the value of Prostaglandin E2 in bood of ammong four constitutiens didn,t showed significant differance. 3.In the constitution which had discriminated by the result of patient of hospital on a dosage of constitutial prescription, the value of Prostaglandin E2 in blood of among four constitutions didn,nt showed signicant differance. 4.In the constitution which had discriminated by colligated three methods(survey, morphological diagrammings,the result of patient of hospital on a dosage of constitutial prescription), the value of Prostaglandin E2 in blood of ammong four constituion didn,t showed significant differnce. 5.In the constitution which had discriminated by survey, a test of significance between the value of Prostaglandin E2 in blood of each constitution and the value of Prostaglandin E2 in blood of the others was conducted. Only the value of Prostaglandin E2 in blood between in the TAE-EUM-IN(太陰人) and the others of female showed significant differance. 6.In the constitution which had discriminated by study on the morphological diagrammings,a test of significance between the value of Prostaglandin E2 in blood of each constitution and the value of Prostaglandin E2 in blood of the others was conducted. Only the value of Prostaglandin E2 in blood between in the SO-EUM-IN(少陰人) and the others of male showed significant differance. 7.In the constitution whichhad discriminated by the result of patient of hospital on a dosage of constitutial prescription,a test of significance between the value of Prostaglandin E2 in blood of each constitution and the value of Prostaglandin E2 in blood of the others was conducted. Only the value of Prostaglandin E2 in blood between in the TAE-EUM-IN(太陰人) and the others of male showed significant differance. 8.In the constitution which had discriminated was the colligated three methods(survey,morphological diagrammings,the result of patient of hospital on a dosage of constitutial prescription),a test of significance between the value of Prostaglandin E2 in blood of each constitution and the value of Prostaglandin E2 in blood of the others didn,t showed significant differnce. In this connected study is inadequete at present. But if the study is done persistently,the analysis of various ingredient in the body enables objectification in differentiation of four types of physical constitution as the supplemental method.

  • PDF

Antinociceptive Effects of Intraperitoneal and Intrathecal Vitamin E in the Rat Formalin Test

  • Kim, Myoung-Joong;Hong, Boo-Hwi;Zhang, En-Ji;Ko, Young-Kwon;Lee, Won-Hyung
    • The Korean Journal of Pain
    • /
    • v.25 no.4
    • /
    • pp.238-244
    • /
    • 2012
  • Background: Vitamin E is widely known to be one of the reactive oxygen species (ROS) scavengers and a drug that can easily be obtained, and it has been shown to attenuate the pain responses induced by various causes in animal pain models. Thus, this experiment was conducted to assess the antinociceptive effects of vitamin E by comparing intraperitoneal and intrathecal injections in rats subjected to the formalin test. Methods: After the intraperitoneal and intrathecal injections of vitamin E were carried out, respectively (IP: 500 mg/kg, 1 g/kg, and 2 g/kg, IT: 3 mg/kg, 10 mg/kg, and 30 mg/kg), the formalin test was perfumed. As soon as 5% formalin was injected into left hind paw, the number of flinches induced by pain was measured at 5-minute intervals for 1 hour. Results: Formalin injected into the left hind paw induced biphasic nociceptive behavior in all animals. Intraperitoneal injection of vitamin E diminished the nociceptive behavior in a dose-dependent manner during the early and late phase. Intrathecal vitamin E diminished nociceptive behavior dose dependently during the late phase but showed no significant difference in the early phase. Conclusions: Vitamin E attenuated acute nociception when it was injected systemically, while both systemic and intrathecal injection produced analgesia in a rat model of formalin-induced hyperalgesia.

Analysis of Partial Least Square Regression on Textural Data from Back Extrusion Test for Commercial Instant Noodles (시중 즉석 조리 면의 Back Extrusion 텍스처 데이터에 대한 Partial Least Square Regression 분석)

  • Kim, Su kyoung;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.75-79
    • /
    • 2010
  • Partial least square regression (PLSR) was executed on curve data of force-deformation from back extrusion test and sensory data for commercial instant noodles. Sensory attributes considered were hardness (A), springiness (B), roughness (C), adhesiveness to teeth (D), and thickness (E). Eight and two kinds of fried and non-fried instant noodles respectively were used in the tests. Changes in weighted regression coefficients were characterized as three stages: compaction, yielding, and extrusion. Correlation coefficients appeared in the order of E>D>A>B>C, root mean square error of prediction D>C>E>B>A, and relative ability of prediction D>C>E>B>A. Overall, 'D' was the best in the correlation and prediction. 'A' with poor prediction ability but high correlation was considered good when determining the order of magnitude.

A Study on the Analysis of Emission Characteristics for Light-duty Diesel Vehicle According to the Severity of the Test Route (주행 경로의 가혹도에 따른 소형 경유 자동차의 배출 특성 분석에 관한 연구)

  • Sangki Oh;Youngjae Jeon;Junepyo Cha
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2024
  • The EU (European Union) was introduced Euro-6e in 2023. Recently, the EU prepare to introduce Euro-7. One of difference Euro-6e and Euro-7 is test route condition. This study developed 5 test routes that have different characteristics and severity. The severity of test routes was made by traffic and road gradient. And this study was conducted RDE test on 5 test routes for Light-Duty diesel vehicle (Euro-6d). Based on the test results, the emission characteristics of CO2 and NOx were analyzed according to the severity of the test routes. Especially, 4 test routes were satisfied normal driving condition of Euro-7 and other test route was satisfied extended driving condition of Euro-7.

Strength Properties of Light-Weighted Soils Mixed with E.P.S (발포스티로폴을 이용한 경량혼합처리토의 강도특성)

  • 김수삼;윤길림;신현영;홍상기
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.615-620
    • /
    • 2000
  • The strength properties of Light-Weighted Soils(LWS) mixed with Expanded Polystrene(E.P.S) are studied. Test results show that when the initial water contents of dredged soils are under 135% and the cement contents are above 1%, Light-Weight Soils are in the appropriate strength range of 2.0 to 4.0kg/㎠. However, E.P.S contents had a little affects on the strength properties of LWS. In the view of E.P.S diagram's effects on LWS, which have expand ratio of 25, 35, 45 and 60, further studies considering of physical properties of original E.P.S beads are needed.

  • PDF

Development of electric Four Wheel Drive System (e-4WD 시스템 개발)

  • Jo, Hee Young
    • Journal of Drive and Control
    • /
    • v.13 no.1
    • /
    • pp.10-17
    • /
    • 2016
  • e-4WD(Electric-4WD) system is a 4WD(4-Wheel Drive) System that can transform a car into a Hybrid System. e-4WD consists of a Motor, Inverter, Speed reducer and Clutch. The Motor, Speed reducer and Clutch are installed on the rear sub-frame as a chassis module type. The inverter is installed separately. Compared to a mechanical 4WD, the e-4WD system has many advantages. For example, the reduced number of drivetrain components makes better use of the space. Driving with a motor only at low speed improves fuel economy and reduces exhaust gas. Engine downsizing is available because the motor assists the engine. The performance of a conventional HEV(Hybrid Electric Vehicle) system can also be maintained. This paper proposes the specifications of components and the control logic for an e-4WD System. And the effect of the e-4WD system is proven using a test vehicle equipped with components under various test conditions.