• 제목/요약/키워드: E test

검색결과 8,680건 처리시간 0.036초

A Review of Structural Testing Methods for ASIC based AI Accelerators

  • Umair, Saeed;Irfan Ali, Tunio;Majid, Hussain;Fayaz Ahmed, Memon;Ayaz Ahmed, Hoshu;Ghulam, Hussain
    • International Journal of Computer Science & Network Security
    • /
    • 제23권1호
    • /
    • pp.103-111
    • /
    • 2023
  • Implementing conventional DFT solution for arrays of DNN accelerators having large number of processing elements (PEs), without considering architectural characteristics of PEs may incur overwhelming test overheads. Recent DFT based techniques have utilized the homogeneity and dataflow of arrays at PE-level and Core-level for obtaining reduction in; test pattern volume, test time, test power and ATPG runtime. This paper reviews these contemporary test solutions for ASIC based DNN accelerators. Mainly, the proposed test architectures, pattern application method with their objectives are reviewed. It is observed that exploitation of architectural characteristic such as homogeneity and dataflow of PEs/ arrays results in reduced test overheads.

Euglena 운동성 측정장치를 이용한 생태독성평가 (Ecotoxicity Test Using E. agilis Biomonitoring System)

  • 이정아;김경남;박다경
    • 환경생물
    • /
    • 제34권2호
    • /
    • pp.124-131
    • /
    • 2016
  • Euglena agilis의 운동성 반응을 자동으로 측정하는 장치인 E. agilis 시스템 (E-Tox)을 이용하여 8종의 중금속 (Ag, Cd, Cr(VI), Cu, Hg, Ni, Pb, Zn)에 대한 독성시험을 실시하였다. E. agilis 운동성 시험 (biomonitoring test)으로부터 도출된 $EC_{50}$과 문헌상의 자료 조사로 얻은 기존 생태독성 시험 생물 종들(D. magna, V. fischeri, 그리고 E. gracilis)의 $EC_{50}$을 비교하여 시험물질에 대한 E. agilis의 독성 민감도를 평가하였다. 또한 축산폐수 방류수, 도금폐수 방류수, 도금폐수 1차 처리 시료에 대해 D. magna 급성 독성시험과 E. agilis 운동성 반응 시험을 수행 후 TU를 비교하여 E. agilis 운동성 시험의 현장 적용 가능성을 평가하였다. E. agilis는 시험 중금속에 대해 D. magna보다 독성민감도가 전반적으로 낮았으나 V. fischeri 또는 E. gracilis와 유사하거나 좀 더 민감하였다. E. agilis는 D. magna test로 유독성으로 판명된 도금폐수 1차 처리수에 대해 신속한 독성반응을 나타내었다. E-Tox 시스템은 기존의 생태독성시험장비에 비해 빠르고 작동이 간편한 자동화 기기라는 장점이 있다. 본 연구의 결과 E-Tox 시스템을 이용한 E. agilis 운동성 시험은 향후 독성폐수에 대한 조기경보를 위한 생태독성시험법으로 적용될 수 있을 것으로 판단된다.

E-VSB 시스템의 필드 테스트 결과 (Field Test Results of E-VSB System)

  • 이용태;박성익;김승원;이수인;서종수
    • 방송공학회논문지
    • /
    • 제11권2호
    • /
    • pp.242-253
    • /
    • 2006
  • 본 논문에서는 Zenith/ATI가 제안하여 ATSC DTV 표준 개정안으로 채택된 Enhanced-VSB(E-VSB) 시스템에 대한 필드 테스트 절차 및 결과를 기술하고, 그 결과를 다양한 각도에서 분석한다. 대전에서 수행된 필드 테스트에서는 E-VSB 시스템의 성능 개선 효과를 분석하기 위해 안테나 종류에 따른 실내 및 실외에서의 수신여부, 잡음 마진 및 수신가능 방위각 등을 측정하였다. 또한, 본 논문에서는 E-VSB 시스템과 기존의 8-VSB 시스템 사이의 상호 호환성(backward compatibility)을 검증하고, 테스트 지점 선정, 송신기 및 측정 차량 구성에 관해서 점검한다. 필드 테스트 결과에 의하면, E-VSB 시스템은 실내 수신과 같은 다중경로가 많은 난시청 환경에서 특히 우수한 성능을 보였을 뿐만 아니라 기존 8-VSB 시스템과 상호 호환성을 유지하였다.

ebXML 지원 솔루션의 표준적합성 테스트 시스템 구축 (Standard Conformance Test System for e-Business Solutions Supporting ebXML)

  • 김동수;윤정희
    • 한국IT서비스학회지
    • /
    • 제2권1호
    • /
    • pp.85-97
    • /
    • 2003
  • This research has designed and implemented the standard conformance test system for e-Business solutions that supports the ebXML, which is currently being focused on as the leading electronic commerce framework. The adoption of standards such as ebXML is probably the best way to achieve interoperability among electronic commerce systems, and more and more e-Business solutions around the world are supporting ebXML. This research primarily discusses the concept and needs for the standard conformance tests on e-Business solutions. The standard conformance test system is developed based on the detailed specifications of the ebXML framework. This system was used to test commercial e-Business solutions supporting ebXML. The system implemented in this research will provide a significant basis for the standard conformance certification of e-Business solutions, and could also provide clear decision criteria for e-Business solutions currently in market, thus activate the overall e-Business market.

컴퓨터 적응형 알고리즘을 이용한 웹기반 시험 시스템 설계 및 구축 (A Design and Implementation of Web-based Test System using Computer-adaptive Test Algorithm)

  • 조성호
    • 컴퓨터교육학회논문지
    • /
    • 제7권6호
    • /
    • pp.69-76
    • /
    • 2004
  • e러닝을 교육과 학습을 위하여 e비즈니스 기술 및 서비스를 사용하는 응용프로그램이다. 이는 원격지 자원과 서비스에 접근을 수월하게 함으로서 교육의 질을 높이기 위한 새로운 멀티미디어 및 인터넷 기술을 사용한다. 본 논문은 실제 TOEFL CBT에 기반을 두어 신중하게 설계되고 구현된 인터넷기반의 시험 시스템에 대하여 기술한다. 본 시스템은 콘텐츠 전달 기술, 컴퓨터 적응형 시험 알고리즘, 리뷰엔진으로 구성되어 있다. 본 논문에서는 컴퓨터기반 시험 시스템을 설계 및 구현 시 고려사항들에 대하여 서술한다.

  • PDF

PCR 기법 이용 VTe 분비 대장균 검출 (Detection of VTe-producing E coli using PCR method)

  • 윤순식;박남용;임정택
    • 대한수의학회지
    • /
    • 제36권3호
    • /
    • pp.607-614
    • /
    • 1996
  • Several methods for rapid and accurate detection of VTe-producing E coli were established. These methods contain beta-glucuronidase-secretion test, beta-haemolysis-production test in blood agar, verocytotoxicity test, and PCR. All of the VTe-producing strains made beta-haemolysis on 5% sheep blood agar. VTe-producing strains secreted beta-glucuronidase whereas 0157:H7 strains producing VTI or VTII did not secrete that enzyme. Verocytotoxicity test was established for rapid diagnosis. VTe detection was rapider in Vero cell suspension than Vero cell monolayer. In PCR, there was a positive result only in VTe-producing E coli, not in VTI or VTII-producing E coli. In this experiment, 165 strains of E coli were islated from feces or intestinal contents of post-weaning piglets showing nervous sign or diarrhea. And 20 strains of E coli that produced VTe were selected by verocytotoxicity test and PCR. According to these experiments, there was a direct correlation between verocytotoxicity test and PCR. And verocytotoxicity test is recommended as a routine diagnostic method and PCR does as a accurate diagnostic method to detect VTe-producing E coli.

  • PDF

Measurement of Antibodies to Varicella-Zoster Virus Using a Virus-Free Fluorescent-Antibody-to-Membrane-Antigen (FAMA) Test

  • Park, Rackhyun;Hwang, Ji Young;Lee, Kang Il;Namkoong, Sim;Choi, Seuk-Keun;Park, Songyong;Park, Hosun;Park, Junsoo
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권2호
    • /
    • pp.268-273
    • /
    • 2015
  • The fluorescent-antibody-to-membrane-antigen (FAMA) test is regarded as the "gold standard" to detect protective antibodies to varicella-zoster virus (VZV) because of its high sensitivity and specificity. Because the classic FAMA test uses an infectious virus for detection of antibodies to VZV, it is labor-intensive, and also requires special equipment for handling the virus. For this reason, we attempted to develop a simple and safe FAMA assay. Because VZV glycoprotein E (gE) is one of the major VZV glycoproteins, we used the gE protein for the FAMA test (gE FAMA). Here, we demonstrate that overexpression of gE in HEK293T cells can be used to measure antibodies in human serum, and that gE FAMA titers are closely correlated with gpEIA ELISA data. These results indicate that our gE FAMA test has the potential to measure antibodies to VZV.

식중독 세균 검출에 있어서 리포좀의 이용 가능성 (Feasibility Study on the Use of Liposomes for Detecting Food-borne Pathogenic Bacteria)

  • 김명희;김왕준;신원선;손동화;차성관
    • 한국축산식품학회지
    • /
    • 제23권3호
    • /
    • pp.278-283
    • /
    • 2003
  • 식중독 세균 검출에 있어서 리포좀의 이용 가능성을 병원성 식중독 세균인 E. coli O157:H7을 대상으로 검토하였다. 리포좀의 표면에 E. coli O157:H7을 인식하는 항체를 공유결합시키고 리포좀의 내부 수용액상에는 형광 표지물질인 sulforhodamine B를 포집시켰다. 이렇게 합성된 면역리포좀이 진단시약으로써의 기능을 하는지 알아보기 위해 두 가지 분석 방법을 적용하였다. 첫번째 방법으로써, test-strip을 이용한 분석은 E. coli O157:H7의 존재 유무를 test-strip 상에 나타난 분석 신호을 육안으로 관찰하는 것으로써 E. coli O157:H7 존재시 분석 신호가 저하되는 것을 원리로하였다. 이 방법은 고가의 실험 장비가 필요하지 않아 현장적용성이 용이한 장점이 있다. 두번째 방법은, IMS 후 목표 세균에 결합되어 있는 리포좀을 파괴시켜 나오는 형광도의 세기를 측정하는 방법으로 이때는 형광도의 강도와 E. coli O157:H7 세균 수와 비례적 관계가 나타났다. 상기의 두 방법에서 얻은 결과는, 리포좀을 E. coli O157:H7 검출에 응용할 수 있는 가능성을 제시하며 추후에 식품 적용 실험이 요구된다.

알레르기 검사의 실제 (Allergy tests in clinical practice)

  • 이재천
    • Journal of Medicine and Life Science
    • /
    • 제15권1호
    • /
    • pp.1-5
    • /
    • 2018
  • Allergy is conditions when a hypersensitivity reaction happens with a certain element, called as an allergen, which is commonly not reactive to ordinary individuals. Allergic diseases involve various organs or systems in the body. The purpose of allergy tests is to make a diagnosis of allergic diseases and to identify the affecting allergens. In vivo tests, more relevant in clinical situation, include skin test, patch test and provocation test. In in vitro tests, there are specific IgE test, histamine releasing assay, and lymphocyte activation test, safer and more objective than in vivo tests. In the view point of clinical practice, skin test, provocation test, total IgE test and specific IgE test were reviewed in depth.

시스템 온 칩 내 eDRAM을 사용한 Tightly Coupled Memory의 병렬 테스트 구조 (A Parallel Test Structure for eDRAM-based Tightly Coupled Memory in SoCs)

  • 국인성;이재민
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.209-216
    • /
    • 2011
  • 최근 시스템 온 칩 내 메모리의 고속 동작을 위해 TCM (Tightly Coupled Memory)를 내장한 설계가 크게 증가하고 있다. 본 논문에서는 시스템 온칩 내 eDRAM을 사용한 TCM 메모리를 위한 새로운 병열 메모리 테스트 구조를 제안한다. 제안하는 기법에서 피테스트 메모리가 테스트 모드에서 병렬 구조로 바뀌고 바운더리 스캔 체인과 함께 내장 메모리의 테스트용이도가 크게 향상된다. 병렬테스트 방식의 메모리는 각 메모리 요소들이 특정한 기능을 수행하도록 구조화되어 있으므로 모듈들로 분할하여 테스트 할 수 있으며 입출력 데이터를 기반으로 동적 테스트 평가 가능하다. 시뮬레이션을 통하여 제안한 기법의 타당성을 검증하였다.