• 제목/요약/키워드: Dynamic steady-state

검색결과 680건 처리시간 0.031초

슬라이딩 모우드를 이용한 위치 서보 운전에 관한 연구 (A Study on Position Servo Drive with Sliding Mode Control)

  • 원종수;민준기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.65-68
    • /
    • 1988
  • In this paper the application of variable structure control with sliding modes for improving the dynamic response and eliminating chattering of DC servo motor drive is presented. Sliding mode control is an effective means to keep a system insensitive to parameter variation and disturbances. In this method the control structure is changed discontinuously to farce the system dynamic to follow a predetermined trajectory. However the discontinuous change in control structure causes the controller input to chatter and gives non-zero steady state error. To overcome this problem, the discontinuous sign function is replaced by a proper continuous function, and presented through experiment.

  • PDF

유한요소해석을 이용한 워터펌프 베어링돌출 설계 개선 (Design Modification of Bearing Walkout of Water Pump by a Finite Element Analysis)

  • 양철호;한문식
    • 한국자동차공학회논문집
    • /
    • 제14권3호
    • /
    • pp.164-169
    • /
    • 2006
  • A systematic methodology has been proposed to establish a reliable design of water pump system. A simplified steady-state dynamic model of water pump system has been developed to study the response of water pump system to the dynamic load mainly due to the run-out and unbalance. Design modifications are needed to strengthen the structural integrity of existing designs. Increasing the natural frequency of system is pursued to prevent a resonance from occurring in the engine excitation range. A computational reliability methodology combined with finite element analysis is used to identify the most significant factor affecting the system performance. This method considered influence of design control parameters for the performance of design. By including control factors to the system model in a systematic way, more reliable design is expected.

유한요소법을 이용한 완전 세라믹의 3차원 과도해 해석 (Three Dimensional Transient Analysis of Piezoelectric Beam Using Finite Element Method)

  • 주현우;이창환;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.608-610
    • /
    • 2000
  • The static characteristic of a piezoelectric beam is for finding resonance frequency of the beam. In practice, it is required to analyze the beam with external command circuit including capacitors, inductors, and resistors for control. It means that the proper analysis of a piezoelectric beam with external command circuit is required by a dynamic analysis. We can also got transient and steady-state solution from the analysis. In this paper, the static and dynamic characteristic of the piezoelectric beam using FEM(Finite Element Method) are proposed.

  • PDF

브러시리스 DC 모터의 모델링과 동특성 해석 (The Analysis of Dynamic Characteristics and Modeling of Brushless DC Motor)

  • 최병인;백수현;김용;윤신용;임태빈;김철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.200-204
    • /
    • 1998
  • In this paper, a mathematical model of Brushless DC machine fed by pwm inverter is developed. Dynamic and steady state characteristics of Brushless DC motor is simulated and analyzed: electromagnetic torque, speed, phase voltage, and current. In mathematical modeling, the shaft transformation referencing rotor frame from to "a,b,c" three phase frame to "d,g" two phase frame is described.

  • PDF

Wire Rope형 배관 지진$\cdot$진동완충기의 설계 (Design of the Wire Rope Type Snubber for Earthquake and Vibration of Piping System)

  • 김영중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.173-179
    • /
    • 1998
  • The piping system of a power plant suffers not only thermal expansion according to the temperature variation, but also many kinds of load: steady state vibrations due to the equipment operation or fluid flow, and transient vibrations due to the earthquake or explosion, etc. The snubbers are usually installed on the piping system to allow thermal expansion, and to reduce dynamic responses. Most snubbers are kinds of hydraulic and mechanical type, which can be degraded by leakage and abrasion, and required much cost for maintenance and replacement. Recently the wire rope type snubbers are developed and applied to the power plant, and proved as effective to reduce piping system vibration. Wire rope type snubber uses the bending rigidity and energy dissipation properties of ropes. This paper presents the procedure of design, and the method to apply hysteresis curve to the dynamic response analysis. Experiments were also conducted to confirm design results.

  • PDF

Dynamic Analysis of Harmonically Excited Non-Linear Structure System Using Harmonic Balance Method

  • 문병영;강범수;김병수
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1507-1516
    • /
    • 2001
  • An analytical method is presented for evaluation of the steady state periodic behavior of nonlinear structural systems. This method is based on the substructure synthesis formulation and a harmonic balance procedure, which is applied to the analysis of nonlinear responses. A complex nonlinear system is divided into substructures, of which equations are approximately transformed to modal coordinates including nonlinear term under the reasonable procedure. Then, the equations are synthesized into the overall system and the nonlinear solution for the system is obtained. Based on the harmonic balance method, the proposed procedure reduces the size of large degrees-of-freedom problem in the solving nonlinear equations. Feasibility and advantages of the proposed method are illustrated using the study of the nonlinear rotating machine system as a large mechanical structure system. Results obtained are reported to be an efficient approach with respect to nonlinear response prediction when compared with other conventional methods.

  • PDF

감압경수형 원자로의 최적부하추종제어에 관한 연구 (A Study of Optimal Load Follow Control in Pressurized Water Reactors)

  • 김락규;박상휘
    • 대한전기학회논문지
    • /
    • 제34권12호
    • /
    • pp.491-497
    • /
    • 1985
  • An applicaton of the linear optimal control theory to the problem or load follow control in pressurized water reactors (PWR) is investigated. In order to perform the steady-state and load follow operation in PWR, a nonlinear model for the reactor and steam generator is derived and linearized at 50% rated power. Simulation tests are performed for 10% demanded load. Comparing the dynamic response of the newly developed optimal load follow controller with those of the integral error feedback controller proposed by Yang, the rise time of dynamic response of the former is about 15 seconds faster than those of the latter, thus the results indicate that the fast response of the optimal load follow controller is verified. The results of this work are directly applicable to the design of the load follow control systems for commercially operated PWRs.

  • PDF

다이나믹 전류보상기를 이용한 V/f 제어 유도전동기 드라이브 시스템의 안정도 향상 (Stability Improvement of a V/f Controlled Induction Motor Drive System using a Dynamic Current Compensator)

  • 정강률
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권6호
    • /
    • pp.402-408
    • /
    • 2004
  • This paper proposes the novel V/f control method to improve the stability of a V/f controlled induction motor drive system. The conventional V/f control method used in the proposed V/f control method is a vector-based method that is slightly different from the existing conventional V/f control method. The proposed control method uses a dynamic current compensator to improve the stability of a V/f controlled induction motor drive system. This proposed method is easy to implement and completely eliminates the motor oscillation phenomenon causing the instability of a V/f controlled induction motor drive system, especially when the system is driven near the resonant frequency in steady-state with light load. Additionally, this paper analyzes theoretically the instability of a V/f controlled induction motor drive system and shows the validity of the Proposed V/f control method through simulation and experimental results.

부하차단시험에 의한 서인천복합화력 발전기.제어계의 모델링 및 검증 (Modeling and verification of generator/control system of Seo-Inchon combined-cycle plant by load rejection test)

  • 최경선;문영환;김동준;추진부;류승헌;권태원
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.501-510
    • /
    • 1996
  • The gas-turbine generator of Seo-Incheon combined-cycle plant was tested for derivation of a model for dynamic analysis. Load rejection and AVR step test was performed to get the dynamic response of generator. The parameters of generator/control system model were determined by these measured data. No-load saturation test was performed for the saturation characteristics of the generator under steady state. V-curve test was also performed so as to find exact generator parameters. Q-axis parameters of generator was derived by measuring power angle. AVR and governor constants have been tuned by their oscillatory period and setting time characteristics. The derived parameters of generator control system is verified by one-machine infinite bus system simulation. (author). 7 refs., 20 figs., 5 tabs.

  • PDF

A Hybrid DTC-DSC Drive for High Performance Induction Motor Control

  • Jidin, Auzani;Idris, Nik Rumzi Nik;Yatim, Abdul Halim Mohamed;Sutikno, Tole;Elbuluk, Malik E.
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.704-712
    • /
    • 2011
  • This paper describes a hybrid induction motor drive system incorporating DTC-hysteresis and Direct Self Control (DSC) schemes to achieve excellent dynamic performance. The control scheme is switched from a circular to a hexagonal flux locus whenever a dynamic condition is encountered. On the other hand, when the motor operates under steady state conditions, a circular flux locus is used. Without major modifications to the simple structure of a basic DTC, hexagonal flux locus operation is established by modifying the flux error status, before it is fed to the look-up table. The feasibility of the proposed hybrid scheme to achieve excellent control performance is verified by experimental results.