• Title/Summary/Keyword: Dynamic imaging

Search Result 492, Processing Time 0.025 seconds

Usefulness of the Salivagram for the Diagnosis of Brain Lesions in Patients with Aspiration Pneumonia (뇌병변 환자에서 흡인성 폐렴 진단을 위한 Salivagram의 유용성)

  • Oh, Shin Hyun;Choi, Yung Sook;Ro, Dong Wook;Nam-Koong, Hyuk;Kim, Jae Sam;Leee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: Bed, living a long time is required in adult patients with brain lesions such as stroke, traumatic brain injury, and Parkinson's disease, causing pneumonia and respiratory diseases may be due to aspiration of food or saliva. In patients with recurrent pneumonia or pulmonary symptoms, there is a need to determine the possibility of pulmonary aspiration due to aspiration of saliva. Materials and Methods: Saliva due to aspiration pneumonia diagnosis in patients with brain lesions request for inspection to the Department of Nuclear Medicine, 10 patients (male 6, female 4) were included in this study. Patients were fasted before the test, $^{99m}Tc_{O4}$ 185 MBq (5 mCi) of less than 1 mL of solution was administered in the oral cavity. Administration and 20 minutes of dynamic imaging acquisition, and immediately after that the static images were acquired. Delayed scan after 2-4 hours if necessary. Results: Positivity rate of all 10 patients was 60%. In 4 patients showed positive reactions after the administration of oral cavity in a 20-minute dynamic imaging were able to confirm whether the aspiration. In the remaining 2 patients, four hours of additional delay tests were able to confirm whether the aspiration. Conclusion: Does not require changes in patient posture compared to the other checks that can be diagnosed with aspiration pneumonia. A simple test and takes less time. Therefore be useful in providing information for the diagnosis and treatment modality.

  • PDF

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

The evaluation of usefulness of Electronic Portal Imaging Device(EPID) (Electronic Portal Imaging Device(EPID)의 유용성 평가)

  • Lee, Yang-Hoon;Kim, Bo-Kyoum;Jung, Chi-Hoon;Lee, Je-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.19-31
    • /
    • 2005
  • Purpose : To supply the information of EPID system and to analyze the possibility of substitution EPID for film dosimetry. Materials & Methods : With amorphous silicon(aSi) type EPID and liquid filled lonization chamber(LC) type EPID, the reproducibility according to focus detector distance(FDD) change and gantry rotation was analyzed, and also the possible range of image acquisition was analyzed with Alderson Rando phantom. The resolution and the contrast of aSi type EPID image were analyzed through Las Vegas phantom and water phantom. DMLC image was analyzed with X-Omat V film and EPID to see wether it could be applied to the qualify assurance(QA) of IMRT. Results : The reproducibility of FDD position was within 1mm, but the reproducibility of gantry rotation was ${\pm}2,\;{\pm}3mm$ respectively. The resolution and the contrast of EPID image were affected by dose rate, image acquisition time, image acquisition method and frame number. According to the possible range of image acquisition of EPID, it is verified that the EPID is easier to use than film. There is no difference between X-Omat V film and EPID images for the QA of IMRT. Conclusion : Through various evaluation, we could obtain lots of useful information about the EPID. Because the EPID has digital data, also we found that the EPID is more useful than film dosimerty for the periodical Qualify Assurance of IMRT. Especially when it is difficult to do point dose measurement with diode or ionization chamber, the EPID could be very useful substitute. And we found that the diode and ionization chamber are difficult to evaluate the sliding window images of IMRT, but the EPID was more useful to do it.

  • PDF

Relationship Between Adenosine-Induced ST Segment Depression During $^{99m}Tc$-MIBI Scintigraphy and The Severity of Coronary Artery Disease (Adenosine 부하 $^{99m}Tc$-MIBI 심근 관류스캔도중 나타나는 ST절 하강과 관상동맥 질환의 중증도와의 관계)

  • Cho, Jung-Ah;Choi, Chung-Il;Kwak, Dong-Suk;Kim, Jeong-Gyun;Bae, Sun-Kun;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Kang, Seung-Wan;Woo, Eon-Jo;Kim, Sin-Woo;Sohn, Sang-Kyun;Chae, Shung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 1994
  • Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent coronary vasodilator with rapid onset of action, short half-life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed $^{99m}Tc$-MIBI imaging after intravenous Infusion of adenosine In 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during $^{99m}Tc$-MIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused Intravenously at a dose of 0.14mg/kg per minute lot 6minutes and $^{99m}Tc$-MIBI was injected at 3 minute. We then com-pared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased $90{\pm}19$ beats/minute in the group with ST depression compared with $80{\pm}16$ beats/minute in the group without ST depression(p<0.05). Baseline systolic blood pressure was significantly higher in the group with ST depression($152{\pm}27$ mmHg) than in the group without 57 depression($140{\pm}21$mmHg, p<0.05). Double product at baseline($10.90{\pm}2.77$ versus $9.55{\pm}2.34\;beats/minute{\times}mmHg$) and during adenosine infusion($12.72{\pm}3.89$ versus $10.83{\pm}2.98\;beats/minute{\times}mmHg$) were significantly higher in the group with ST depression(p<0.05). The incidence of anginal chest pain was also significantly higher in the group with ST depression(ST versus 29%, p<0.0001). The $^{99m}Tc$-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p<0.05). In patients with ST segment depression, there were more reversible perfusion defects than in patients without ST segment depression(83 versus 55%, p<0.05). The number of abnormal segments were significantly higher in the group with ST depression($3.05{\pm}2.01$ versus $1.51{\pm}1.45$, p<0.005). In patients with ST segment depression, there were more segments of reversible perfusion defects than in patients without segment depression($2.15{\pm}2.11$ versus $0.89{\pm}1.24$, p<0.05). There were no differences in the angiographic severity by vessel(p ; NS). We concluded that ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy with Intravenous adenosine is related to the severity of coronary artery disease.

  • PDF

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Usefulness of MRCP in the Diagnosis of Common Bile Duct Dilatation caused by Non-stone or Non-tumorous Conditions (비결석, 비종양성 총담관 확장의 진단에 있어서 자기공명담췌관조영술(MRCP)의 유용성)

  • 정재준;양희철;김명진;김주희;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2002
  • Purpose : To evaluate the usefulness of MRCP in the diagnosis of the variable causes of common bile duct(CBD) dilatation, except stone or tumor Materials and methods : Twenty-six patients(M:F=15:11, mean age; 62 years) with both MRCP and ERCP were included in this study. Dynamic MRCP(n=12) and contrast-enhanced MRI(n=10) of abdomen were also added. Dilatation of CBD, intrahepatic ducts and pancreatic duct was evaluated, including coexistence of intrahepatic ductal stone, pancreatic pseudocyst, and papillary or papillary edema. The criteria of CBD dilatation was over than 7mm(n= 21, without cholecystectomy) or 10 mm(n=5, with cholecystecto-my) in diameter on T2-weighted coronal image. Results : The mean diameter of CBD was 12.7mm without cholecystectomy(9-19 mm) and 13.0 mm with cholecystectomy(10-15mm), respectively(p 〉0.05). Cholangitis(n=11, 42.3%), chronic pancreatitis(n=8, 30.8%), stenosis of distal CBD(n= 6, 23.1%), periampullary diverticulum(n=3, 11.5%), stenosis of ampulla of Vater(n=2, 7.7%), dysfunction of sphincter of Oddi(n=2, 7.7%), acute focal pancreatitis in the pancreatic head(n=2, 7.7%), papillitis(n=1, 3.8%), pseudocyst in the pancre atic head(n = 1, 3.8%), and ascaris in CBD(n=1, 3.8%) were noted. Pancreatic duct dilatation(n=10, 38.5%) and duodenal diverticulum(n=3, 11.5%) were also seen on MRC P. On dynamic MRCP(12 patients), distal CBD was visualized in 2 patients(16.7%), which was not shown on routine MRCP. Only 1 patient(10.0%) showed papillitis with slightly enhancing papilla on contrast-enhanced MRI (10 patients). Conclusion : MRCP was thought to be helpful in the evaluation of the causes of CBD dilatation, not caused by stone or tumor, especially in the cases of stenosis of distal CBD and chronic pancreatitis, dysfunction of sphincter of Oddi on dynamic MRCP and cholangitis and pericholangitic abnormality on contrast-enhanced MRI.

  • PDF

Kit Preparation and Biodistribution of $Bz-MAG_3$ (benzoylmercaptoacetylglycylglycylglycine) for Renal Imaging (신장기능영상용 방사성의 약품 $Bz-MAG_3$(Benzoylmercaptoacetylglycylglycylglycine) 의 키트화 및 체내분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Cho, Jung-Hyuk;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.367-371
    • /
    • 1996
  • The $MAG_3$ is a tubular excreting radiopharmaceutical for renal image. We synthesized benzoyl $MAG_3\;(Bz-MAG_3)$ and made a kit for labeling with $^{99m}Tc$. We checked the labeling efficieny of $^{99m}Tc$ labeled $MAG_3$ and biodistribution. Labeling efficieny was checked by TLC-SG (acetonitrile/$H_2O$=2/1). After injecting of 1 mCi of $^{99m}Tc-MAG_3$ to ICR-mice, $T_{max}(min),\;T_{1/2}(min)$ were obtained in the renogram. Sequential images (30sec, 2min, 5min, 10min, 15min, 20min) of $^{99m}Tc-MAG_3$ were compared with those of commercial $^{99m}Tc$-DTPA (Du Pont Merck Pharmaceutical Co.) kit. 1) The $R_f$ value of synthesized $^{99m}Tc-MAG_3$ was 0.78 and labeling efficiency was $97.5{\pm}1.9%$ (n=10). 2) The dynamic images of the $^{99m}Tc-MAG_3$ were better than those of the $^{99m}Tc$-DTPA. 3) The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc-MAG_3$ (n=10) were $1.5{\pm}0.5$ (left), $1.4{\pm}0.4$ (right), and $4.3{\pm}1.4$ (left), $4.8{\pm}2.0$ (right), respectively. The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc$-DTPA (n=7) were $2.7{\pm}1.6$ (left), $2.7{\pm}1.6$ (right), and $3.8{\pm}1.7$ (left), $4.5{\pm}2.7$ (right), respectively. The quaility of image and labeling efficiency of the synthesized $Bz-MAG_3$ kit were excellent, that it was supposed to be used in routine clinical work.

  • PDF