• 제목/요약/키워드: Dynamic calibration system

검색결과 88건 처리시간 0.027초

로봇의 위치 정밀도 측정을 위한 LTS의 설계 및 제작 (Design and Manufacture of Laser Tracking System for Measuring Position Accuracy of Robots)

  • 황성호;이호길;최령락;송웅희;김진영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.434-434
    • /
    • 2000
  • It is the main problem to measure the position and orientation of a robot end effector for the calibration of robots. The calibration methods can be used as a tool to improve the accuracy of robots without change of the arm or control architecture of robots. But such calibration methods require the accurate measurements. Dynamic measurement of position and orientation Provides a solution of this problem and improves dynamic accuracy by dynamic calibration o( robots. This paper describes the development o( the laser tracking system capable of determining the static and dynamic performance of industrial robots. The structure and system components are presented and basic experimental results are included to demonstrate the instrument performance. The system can be applied to the remote controlled mobile robots as weil as the calibration of robots.

  • PDF

Combined Static and Dynamic Platform Calibration for an Aerial Multi-Camera System

  • Cui, Hong-Xia;Liu, Jia-Qi;Su, Guo-Zhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권6호
    • /
    • pp.2689-2708
    • /
    • 2016
  • Multi-camera systems which integrate two or more low-cost digital cameras are adopted to reach higher ground coverage and improve the base-height ratio in low altitude remote sensing. To guarantee accurate multi-camera integration, the geometric relationship among cameras must be determined through platform calibration techniques. This paper proposed a combined two-step platform calibration method. In the first step, the static platform calibration was conducted based on the stable relative orientation constraint and convergent conditions among cameras in static environments. In the second step, a dynamic platform self-calibration approach was proposed based on not only tie points but also straight lines in order to correct the small change of the relative relationship among cameras during dynamic flight. Experiments based on the proposed two-step platform calibration method were carried out with terrestrial and aerial images from a multi-camera system combined with four consumer-grade digital cameras onboard an unmanned aerial vehicle. The experimental results have shown that the proposed platform calibration approach is able to compensate the varied relative relationship during flight, acquiring the mosaicing accuracy of virtual images smaller than 0.5pixel. The proposed approach can be extended for calibrating other low-cost multi-camera system without rigorously mechanical structure.

로봇의 위치 정밀도 측정을 위한 LTS의 설계 및 제작 (Design and Manufacture of Laser Tracking System for Measuring Position Accuracy of Robots)

  • 황성호;이호길;최경락;김진영
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.518-522
    • /
    • 2001
  • The main problem of the calibration of robots is to measure the position and orientation of a robot end effector. The calibration methods can be used as tool to improve the accuracy of robots without change of the arm or control architecture or robots. But such calibration methods require accurate measurements. Dynamic measurement of position and orientation provides a solution for this problem and improves dynamic accuracy by dynamic calibration of robots. This paper describes the development of the laser tracking system capable of determining the static and dynamic performance of industrial robots. The structure and systems components are presented and basic experimental results are included to demonstrated the instrument performance. The system can be applied to the remote controlled mobile robots as well s the calibration of robots.

  • PDF

압전형 압력센서의 교정기법 자동화 (An automatic calibration technique for piezoelectric pressure transducers)

  • 홍성수;최주호;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1368-1371
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectric low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

압전형 압력센서의 교정기법 자동화 (An Automatic Calibration Technique for Piezoelectric Pressure Transducers)

  • 홍성수;최주호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1012-1016
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectic low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

이중 파장 보정방법 기반 다이나믹 분광타원편광계의 안정도 최적화 (Long-term Stability Optimization of Dynamic Spectroscopic Ellipsometery based on Dual-wavelength Calibration)

  • 최인호;헤리저데헌거흐 사이드;최석현;황국현;심준보;김대석
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.178-183
    • /
    • 2021
  • This paper describes a dynamic spectroscopic ellipsometry based on dual-wavelength calibration. DSE provides ellipsometric parameters at rates above 20 Hz, but the interferometer's sensitivity to temperature makes it difficult for that proposed system to maintain stable 𝜟k over long periods of time. To solve this problem, we set up an additional path in the DSE to perform simulations of the polarization phase calibration method using dual wavelengths. Through simulation, we were able to eliminate most of the polarization phase error and maintain a stable 𝜟k in the long-term stability experiment for 10 hours. This is the result that the 𝜟k stability of the proposed system is improved tens of times compared to the existing system.

동적 보정을 이용한 비주얼 서보잉에서 안정성에 관한 연구 (A Stability Study on Visual Servoing using Dynamic Calibration)

  • 김진대;조영식;이상화;이재원
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.82-88
    • /
    • 2003
  • Many visual servoing algorithms have been recently developed by the robot vision researchers. They do not, however, consider the stability of servoing system. The camera calibration is the most important factor to the control stability and performance of position based visual servoing. In this article we describe the ECL(End Point Closed Loop) servoing can make no steady state error for the control of 6-DOF robot of which accuracy is dependent on the camera calibration and kinematics. And we propose a dynamic calibration algorithm, which can improve stability and performance of ECL visual servoing. To verify the potential of our approach, we run assembly experiments and present our finding.

DIRECT INVERSE ROBOT CALIBRATION USING CMLAN (CEREBELLAR MODEL LINEAR ASSOCIATOR NET)

  • Choi, D.Y.;Hwang, H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1173-1177
    • /
    • 1990
  • Cerebellar Model Linear Associator Net(CMLAN), a kind of neuro-net based adaptive control function generator, was applied to the problem of direct inverse calibration of three and six d.o.f. POMA 560 robot. Since CMLAN autonomously maps and generalizes a desired system function via learning on the sampled input/output pair nodes, CMLAN allows no knowledge in system modeling and other error sources. The CMLAN based direct inverse calibration avoids the complex procedure of identifying various system parameters such as geometric(kinematic) or nongeometric(dynamic) ones and generates the corresponding desired compensated joint commands directly to each joint for given target commands in the world coordinate. The generated net outputs automatically handles the effect of unknown system parameters and dynamic error sources. On-line sequential learning on the prespecified sampled nodes requires only the measurement of the corresponding tool tip locations for three d.o.f. manipulator but location and orientation for six d.o.f. manipulator. The proposed calibration procedure can be applied to any robot.

  • PDF

홉킨슨 압력봉(Hopkinson pressure bar)을 이용한 동적 충격센서 보정기술 연구 (A Study on the Calibration Method for Dynamic Shock Sensor Using Hopkinson Pressure Bar System)

  • 오세욱;민경조;조상호
    • 화약ㆍ발파
    • /
    • 제38권1호
    • /
    • pp.23-29
    • /
    • 2020
  • 발파나 충격과 관련된 연구에서 충격센서를 이용한 하중 및 진동의 계측이 널리 사용되고 있다. 하지만 대부분의 충격센서는 고가이며 외부로부터의 손상에 대해 보호할 필요성이 존재한다. 본 연구에서는 충격센서의 외부 구조적 변화에 따른 계측 대상 매질로부터 입사되는 하중정보의 왜곡현상을 보정할 수 있는 방법에 대해 고찰하였다. 홉킨슨 압력봉 시스템을 이용해 충격센서로 전달되는 충격가속도를 산출하였으며, 이와 동시에 충격진동의 감쇠를 야기하는 센서 홀더를 고안 및 적용하여 센서의 출력 값에 대한 비교분석을 수행하였다. 결과적으로 센서에 적용된 외부 구조적 변화가 센서의 진동운동 자체를 왜곡시키는 비선형 거동이 아닌 경우 본 방법을 통한 충격센서 보정기술이 합리적으로 작용할 수 있을 것으로 판단하였다.

Robust Electric Compass to Dynamic Magnetic Field Interference

  • Ko, Jae-Pyung;Kim, Yang-Hwan;Kang, Woong-Ki;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1814-1819
    • /
    • 2004
  • The purpose of this research is to improve the reliability of automobile navigation system that utilizes the magnetic compass for localization. On account of its sensitiveness against the dynamic external interference of the magnetic field, the electronic compass itself is not accurate enough to be used for the localization compared to the gyro-compass. To overcome this shortcoming, in this research, a robust electronic compass is designed by using two magnetic compasses to cancel out the dynamic interferences efficiently. That is, a dual compass predictive calibration algorithm against irregular external interference of magnetic field is newly proposed and implemented in this paper. When the dynamic interference can be eliminated from the electronic compass, it becomes much accurate than the gyro-based system that suffers from the accumulative drift error. The reliability and performance of the designed system have been verified through the real driving experiments.

  • PDF