• 제목/요약/키워드: Dynamic Load Time History

검색결과 156건 처리시간 0.025초

Comparison between wind load by wind tunnel test and in-site measurement of long-span spatial structure

  • Liu, Hui;Qu, Wei-Lian;Li, Qiu-Sheng
    • Wind and Structures
    • /
    • 제14권4호
    • /
    • pp.301-319
    • /
    • 2011
  • The full-scale measurements are compared with the wind tunnel test results for the long-span roof latticed spatial structure of Shenzhen Citizen Center. A direct comparison of model testing results to full-scale measurements is always desirable, not only in validating the experimental data and methods but also in providing better understanding of the physics such as Reynolds numbers and scale effects. Since the quantity and location of full-scale measurements points are different from those of the wind tunnel tests taps, the weighted proper orthogonal decomposition technique is applied to the wind pressure data obtained from the wind tunnel tests to generate a time history of wind load vector, then loads acted on all the internal nodes are obtained by interpolation technique. The nodal mean wind pressure coefficients, root-mean-square of wind pressure coefficients and wind pressure power spectrum are also calculated. The time and frequency domain characteristics of full-scale measurements wind load are analyzed based on filtered data-acquisitions. In the analysis, special attention is paid to the distributions of the mean wind pressure coefficients of center part of Shenzhen Citizen Center long-span roof spatial latticed structure. Furthermore, a brief discussion about difference between the wind pressure power spectrum from the wind tunnel experiments and that from the full-scale in-site measurements is compared. The result is important fundament of wind-induced dynamic response of long-span spatial latticed structures.

비좌굴가새가 설치된 골조의 비탄성거동 (Inelastic Behavior of Steel Frames with Buckling Restrained Braced)

  • 김진구;박준희
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.97-104
    • /
    • 2005
  • The seismic behavior of framed structure with Chevron-type bucking restrained braces were investigated and their behavior factors were evaluated following the procedure proposed in ATC-19 & ATC-34. Two types of structures, building frame systems and dual systems, with 4, 8, 12, and 16 stories were designed per the IBC 2000, the AISC LRFD and the AISC/SEAOC Recommended Provisions for BRBF. Nonlinear static pushover analyses were carried out to observe the plastic hinge formation and to identify the loads and the displacements at the yield and the ultimate states. Time history analyses were also carried out to compute the permanent displacement md the dissipated hysteretic energy. According to the analysis results, the response modification factors of model structures fumed out to be larger than what is proposed in the provision in low story structures, and a little smaller in medium-story structures. The dual systems, even though designed with smaller seismic load, showed superior static and dynamic performances.

  • PDF

송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기 (Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines)

  • 문병욱;민경원
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.

강 거더교의 수직보강재 응답을 이용한 주행차량의 특성 추정 (Identification of Running Vehicle Properties by Vertical Stiffener Response of Steel Girder Bridge)

  • 이희현;전준창;정민선;경갑수
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.86-95
    • /
    • 2012
  • The BWIM(Bridge Weigh-In-Motion) is a technology to identify vehicle properties, such as weight, speed, axle spacing and running lane, passing over a bridge by using dynamic response of bridge member. Such information will be used for assessing durability and establishing a maintenance strategy of roadway structures. In this paper, as a first step for developing BWIM system, analytical and experimental studies were conducted in order to verify whether the response of vertical stiffener in steel girder bridge can be used to identify vehicle properties running on the bridge. It was known from this study that such vehicle information could be estimated reasonably by using strain time history curve of a vertical stiffener due to running vehicles. It is because the effect of each axle-load of vehicle appears definitely in the curve. However, as the magnitude of strain of vertical stiffener is effected by running pattern of vehicles, further study is necessary to reduce error when estimating vehicle weight.

아웃리거 댐퍼시스템의 고층건물 지진응답제어 성능 평가 (Evaluation of Vibration Control Performance of Outrigger Damper System for Tall Buildings Subjected to Seismic Load)

  • 윤성욱;이령경;김광일;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제16권1호
    • /
    • pp.95-104
    • /
    • 2016
  • Recently, the concept of damped outrigger system has been proposed for tall buildings. But, structural characteristics and design method of this system were not sufficiently investigated to date. In this study, the dynamic response control performance of outrigger damper has been analyzed. To this end, a simplified analysis model with outrigger damper system has been developed. Use the El Centro seismic(1940, NS) analysis was performed. Analysis results, on the top floor displacement response to the earthquake response, did not have a big effect. However, acceleration response control effect was found to be excellent. The increase of outrigger damper capacity usually results in the improved control performance. However, it is necessary to select that proper stiffness and damping values of the outrigger damper system because, the outrigger damper having large capacity is result in heavy financial burden.

Investigations on a vertical isolation system with quasi-zero stiffness property

  • Zhou, Ying;Chen, Peng
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.543-557
    • /
    • 2020
  • This paper presents a series of experimental and numerical investigations on a vertical isolation system with quasi-zero stiffness (QZS) property. The isolation system comprises a linear helical spring and disk spring. The disk spring is designed to provide variable stiffness to the system. Orthogonal static tests with different design parameters are conducted to verify the mathematical and mechanical models of the isolation system. The deviations between theoretical and test results influenced by the design parameters are summarized. Then, the dynamic tests for the systems with different under-load degrees are performed, including the fast sweeping tests, harmonic excitation tests, and half-sine impact tests. The displacement transmissibility, vibration reduction rate, and free vibration response are calculated. Based on the test results, the variation of the transmission rule is evaluated and the damping magnitudes and types are identified. In addition, the relevant numerical time history responses are calculated considering the nonlinear behavior of the system. The results indicate that the QZS isolation system has a satisfactory isolation effect, while a higher damping level can potentially promote the isolation performance in the low-frequency range. It is also proved that the numerical calculation method accurately predicts the transmission character of the isolation system.

서버 클러스터 환경에서 에너지 절약을 위한 동적 서버 전원 모드 제어 (A Dynamic Server Power Mode Control for Saving Energy in a Server Cluster Environment)

  • 김호연;함치환;곽후근;권희웅;김영종;정규식
    • 정보처리학회논문지C
    • /
    • 제19C권2호
    • /
    • pp.135-144
    • /
    • 2012
  • 기존의 서버 클러스터 환경에서는 모든 서버가 항상 On된다. 만일 서버 요청 부하가 최대가 되면 서버 클러스터에서 얻을 수 있는 가능한 최대 성능을 얻게 되며, 그렇지 않으면 가능한 최대 성능의 일부만을 사용하게 되면서 서버 전력 소비의 효율성은 떨어지게 된다. 부하 상황에 따라 서버의 전력 모드를 제어함으로써 전력 소비의 효율성을 높일 수 있다. 다시 말하면 현재 부하를 처리하는데 필요한 대수의 서버들만 On하고 나머지 서버들은 Off 한다. 기존의 서버 전원 모드 제어 방법에서는 고정된 주기로 서버 전원 모드를 제어하는 정적인 정책을 적용함으로써 동적으로 변하는 부하 환경에 잘 적응하지 못한다. 이를 개선하기 위해 본 논문에서는 동적 서버 전원 제어 알고리즘을 제안한다. 제안 방법에서는 서버 소비 전력의 이력을 갖고서 가까운 장래에 서버 소비 전력이 증가할 것인가를 예측한다. 이 예측에 따라 서버 모드 제어 주기를 동적으로 변경한다. 30대의 PC 클러스터를 이용하여 실험을 수행하였다. 실험을 통하여 일반적인 클러스터링 환경과 비교하여 제안된 방법은 동일한 성능을 유지하면서 29%까지 소비 전력을 절감했다. 또한, 서버 클러스터에서 서버 CPU 사용률 평균은 66% 증가하였다.

폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part B: 고유주기에 따른 폭발하중 지속시간의 영향 분석 - (Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part B: Analysis for the Effect of Explosion Loading Time According to the Natural Period for Target Structures -)

  • 강기엽;최광호;류용희;최재웅;이제명
    • 한국전산구조공학회논문집
    • /
    • 제28권2호
    • /
    • pp.197-205
    • /
    • 2015
  • 가스 생산용 해양플랜트 설비의 경우 폭발의 위험에 노출되어 있으며, 폭발사고는 구조물의 안전성에 치명적인 영향을 미칠 수 있다. 따라서, 이러한 폭발사고에 의한 피해를 최소화하기 위해서는, 폭발하중에 의한 구조부재의 동적응답 특성을 명확히 파악할 필요가 있다. 폭발하중의 경우 매우 짧은 시간 동안에 구조물에 가격되었다가 소멸되기 때문에 구조부재의 고유주기 및 폭발하중의 지속시간을 고려한 동적응답 평가가 필수적으로 요구된다. 일반적으로 가스 폭발하중의 경우, 부 압력단계가 전체 하중 이력에서 상당 부분 존재하며, 본 연구에서는 이러한 부 압력단계의 형상에 따라 총 하중 지속시간을 결정하는 하중 모델을 제안하였다. 방화벽은 폭발사고 시 장비 및 인명 피해를 방지하고자 FPSO 탑사이드 모듈 사이에 배치되는 구조부재이므로 폭발하중에 의한 응답이력 특성 분석이 반드시 필요하다. 때문에 무 감쇠 단 자유도 모델에 가스 폭발하중을 적용하여 변위응답 특성을 분석하였으며, 평판으로 구성된 방화벽의 FE 모델을 이용한 하중 지속시간과 구조부재들의 고유주기를 고려한 응답 특성을 분석하였다. LS-DYNA를 이용한 선형/비선형 구조해석 분석결과, 부 압력단계의 지속시간이 구조물의 동적응답에 큰 영향을 주는 것을 보였다.

대형 컨테이너선의 플레어 슬래밍 계측 연구 (II) - 슬래밍 압력 특성 분석 - (A Study on Measurement of Flare Slamming of Large Container Vessel (II) - Characteristic Analysis of Measured Slamming Pressure -)

  • 이탁기;임채환;김영남;허주호;김병현
    • 대한조선학회논문집
    • /
    • 제44권3호
    • /
    • pp.279-284
    • /
    • 2007
  • As a container vessel becomes larger, the bow flare becomes larger. The large bow flare structures are often subjected to dynamic pressure loads due to bow flare slamming occurring in rough seas. The aim of this paper is to investigate the characteristics of bow flare slamming pressure measured in a real voyage through the North Pacific Ocean. The characteristics of impact pressure load caused by slamming is addressed in terms of the pressure pulse-time history which involves rising time, peak pressure, decaying time and type of pressure decay. The values were presented using non-dimensional parameters.

레일 파단시 장대레일 개구부에서의 궤도-차량 동적상호작용 (Dynamic Interaction of Track and Train System on Open Gap by Rail Breaks)

  • 강윤석;강영종;양신추
    • 대한토목학회논문집
    • /
    • 제28권6D호
    • /
    • pp.895-904
    • /
    • 2008
  • 장대레일은 동절기에 중위온도 이하로 떨어져 레일의 인장파단에 의해 개구부가 발생할 수 있다. 레일 파단을 미리 감지 못하는 경우에 개구부에서 동적하중에 의해서 차륜과 레일의 파손이 발생할 수 있으며, 열차주행 안전성이 감소될 수 있다. 본 연구에서는 개구부에서의 궤도와 차량의 동적거동 분석을 위해 레일 파단시 개구부에서의 궤도와 차량의 상호작용을 고려한 동적해석모델을 제안하였다. 궤도와 차량의 선형시스템은 비선형 헤르찌안 접촉 스프링에 의해 연성되었으며 전체 궤도-차량 시스템 운동방정식을 정식화하였다. 그리고 개구부에서의 상호작용 현상을 고려하여 궤도 불균일부의 함수를 정의하고 개구부에서의 전후방 레일 사이의 개구량을 고려하였다. 비선형 방정식을 풀기위해 동적해석은 $Newmark-{\beta}$ 방법에 의해 수행되었다. 그리고 차량속도, 개구량, 레일지지강성에 따른 매개변수에 대한 궤도-차량의 동적상호작용해석을 수행하였고 변수에 대한 영향을 분석하였다.