• 제목/요약/키워드: Dynamic Load Rating

검색결과 37건 처리시간 0.023초

Fuzzy PID Controller for Accurate Power Sharing in DC Microgrid

  • Nguyen, Duy-Long;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.115-117
    • /
    • 2019
  • In this paper, an intelligent control scheme based on Fuzzy PID controller is proposed for accurate power sharing in DC Microgrid. The proposed Fuzzy PID controller is designed with the aid of a closed loop control based on per unit power of each distributed generator (DG), and accurate power sharing is successfully realized in proportional to each DG's power rating regardless of the line resistance difference or the load change. Thanks to Fuzzy PID controller, the dynamic response becomes faster and the stability of the microgrid system are improved in comparison to conventional PID controller. The superiority of the proposed method is analyzed and verified by simulation in Matlab and Simulink.

  • PDF

고가교 경량화에 따른 성능개선 (Performance Improvement of Overpass Bridge by Weight Reduction)

  • 김성배;남상혁;김장호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.51-60
    • /
    • 2011
  • 본 연구에서는 환경적인 요인으로 인한 성능저하현상으로 내구성 저하가 예상되는 건대-구의간 고가교의 현재 상태를 분석하고 내구성 저하로 인한 내구연한의 감소를 막기 위하여 고가교 구조물의 경량화를 통한 성능개선을 수행하고자 한다. 경량화 작업은 콘크리트 방음벽을 경량재 방음벽으로, 도상을 자갈도상에서 콘크리트 도상으로, 마지막으로 트라프를 경량화 함으로써 고가교 전체의 경량화를 유도한다. 이러한 고가교 경량화에 따른 정적 및 동적 거동 변화와 성능개선 효과를 분석하고, PSC I 형교 구간의 내하율 증진에 의한 구조안전성을 확인한다. 경량화 결과 구조물의 처짐이 2.6mm가 감소하고 1.07MPa의 인장응력이 감소된 것으로 평가되어 대상 구조물의 구조성능이 효과적으로 개선되었음을 알 수 있다. 고유진동수도 경량화에 따라 약 30% 증가하여 진동이 감소하고 동적거동이 향상되었다. 또한, 해석 및 계측 결과를 근거로 하여 대상교량의 내하력을 평가한 결과, 경량화에 따라 내하율이 1.82에서 1.93으로 증가하여 경량화에 따른 성능개선 효과가 우수한 것으로 판명되었다.

의사정적재하시험 응답보정계수에 의한 교량 해석모델 보정의 타당성 분석 (Feasibility Analysis of the Bridge Analytical Model Calibration with the Response Correction Factor Obtained from the Pseudo-Static Load Test)

  • 한만석;신수봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.50-59
    • /
    • 2021
  • 현재 공용중인 교량에 대한 재하시험으로 계측한 응답과 초기해석모델의 해석 응답을 비교하여 응답보정계수를 계산하고, 이 모델을 사용하여 내하율과 내하력을 평가하는 방법을 적용하고 있다. 그러나 이러한 응답보정계수는 계측 위치와 하중 조건에 따라 변동하는 값을 준다. 특히 초기해석모델이 교량의 거동에 합당하지 않은 경우, 그 변동 폭이 크며 보정된 모델에 의한 해석 응답이 계측된 응답과 동떨어진 결과를 줄 수 있다. 본 연구에서는 저속으로 주행하는 차량의 다양한 하중 조건에서 동적 성분을 제거한 정적 응답을 얻기 위해 의사정적재하시험법을 적용하였다. 두 개의 유사한 PSC-I 거더교에서 정적 응답을 계측하고, 두 교량 각각에 대한 변위와 변형률에 대한 응답보정계수를 계산하였다. 초기해석모델이 제대로 설정되어 있지 않다면, 평균적으로 구한 응답보정계수로 보정한 모델의 해석 응답이 계측 응답과 오차범위 내에 들어오는지 않음을 확인하였다.

다중 HBPI 제어기를 이용한 유도전동기 드라이브의 최대토크 제어 (Maximum Torque Control of Induction Motor Drive using Multi-HBPI Controller)

  • 강성준;고재섭;최정식;백정우;장미금;김순영;정동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.363-366
    • /
    • 2009
  • The maximum output torque developed by the machine is dependent on the allowable current rating and maximum voltage that the inverter can supply to the machine. Therefore, to use the inverter capacity fully, it is desirable to use the control scheme considering the voltage and current limit condition, which can yield the maximum torque per ampere over the entire speed range. This controller is controlled speed and current using hybrid PI(HBPI) controller and estimation of speed using ANN. Also, this paper is proposed control of maximum torque per ampere(MTPA) of induction motor. This strategy is proposed which is simple in structure and has the honest goal of minimizing the stator current magnitude for given load torque. The performance of the proposed induction motor drive with maximum torque control using HBPI controller is verified by analysis results at dynamic operation conditions.

  • PDF

DSP Based Series-Parallel Connected Two Full-Bridge DC-DC Converter with Interleaving Output Current Sharing

  • Sha, Deshang;Guo, Zhiqiang;Lia, Xiaozhong
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.673-679
    • /
    • 2010
  • Input-series-output-parallel (ISOP) connected DC-DC converters enable low voltage rating switches to be used in high voltage input applications. In this paper, a DSP is adopted to generate digital phase-shifted PWM signals and to fulfill the closed-loop control function for ISOP connected two full-bridge DC-DC converters. Moreover, a stable output current sharing control strategy is proposed for the system, with which equal sharing of the input voltage and the load current can be achieved without any input voltage control loops. Based on small signal analysis with the state space average method, a loop gain design with the proposed scheme is made. Compared with the conventional IVS scheme, the proposed strategy leads to simplification of the output voltage regulator design and better static and dynamic responses. The effectiveness of the proposed control strategy is verified by the simulation and experimental results of an ISOP system made up of two full-bridge DC-DC converters.

건물유형 및 지역조건에 따른 ECO2 및 TRNSYS의 냉난방부하 비교분석 (Comparison Analysis of Cooling and Heating Demand by Building Type and Region using ECO2 and TRNSYS)

  • 박동진;이현재;오진환;권영식;양재광;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2023
  • In Korea, it is also mandatory for most buildings to receive energy efficiency rating certification from 2020 for the purpose of reducing greenhouse gas emissions and expanding green buildings. However, the issue of the accuracy of the ECO2 program continues to be raised, and comparisons have been made with dynamic energy analysis programs in a single type of building according to a single area. However, comparisons between multiple building types and multiple areas are insufficient. Therefore, in this study, cooling and heating loads according to multiple building types and multiple areas were analyzed through ECO2 and TRNSYS programs. The regions were supposed to be Seoul, Daejeon, Gwangju, and Busan and the building types were supposed to be office buildings and apartment houses. The annual average building load values from ECO2 were higher than those from TRNSYS. Among residential buildings across the four regions, the largest discrepancy was 41.4% in Seoul. Conversely, for commercial buildings, the most significant difference in annual average loads was noted in Gwangju, at 37.9%.

FNN 제어기를 이용한 유도전동기 드라이브의최대토크 제어 (Maximum Torque Control of Induction Motor Drive using FNN Controller)

  • 정동화;김종관;박기태;차영두
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.33-39
    • /
    • 2005
  • 본 논문에서는 퍼지와 신경회로망을 혼합한 FNN(Fuzzy Neural Network) 제어기를 이용한 유도전동기의 최대 토크 제어를 제시한다. 먼저 유도전동기 드라이브의 고성능 제어를 위하여 FNN 제어기를 설계한다. 다음은 유도전동기의 최대토크 제어를 위하여 주어진 부하토크에서 고정자 전류를 최소화하여 단위 전류당 발생토크를 높인다. 본 논문에서 제시한 FNN을 이용한 최대토크 제어의 특성을 분석하고 그 결과를 제시한다.