• Title/Summary/Keyword: Dynamic Breast MRI

Search Result 19, Processing Time 0.021 seconds

Ultrafast Dynamic Contrast-Enhanced Breast MRI: Lesion Conspicuity and Size Assessment according to Background Parenchymal Enhancement

  • Soo-Yeon Kim;Nariya Cho;Yunhee Choi;Sung Ui Shin;Eun Sil Kim;Su Hyun Lee;Jung Min Chang;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.561-571
    • /
    • 2020
  • Objective: To evaluate the clinical utility of ultrafast dynamic contrast-enhanced (DCE)-MRI compared to conventional DCE-MRI by studying lesion conspicuity and size according to the level of background parenchymal enhancement (BPE). Materials and Methods: This study included 360 women (median age, 54 years; range, 26-82 years) with 361 who had undergone breast MRI, including both ultrafast and conventional DCE-MRI before surgery, between January and December 2017. Conspicuity was evaluated using a five-point score. Size was measured as the single maximal diameter. The Wilcoxon signed-rank test was used to compare median conspicuity score. To identify factors associated with conspicuity, multivariable logistic regression was performed. Absolute agreement between size at MRI and histopathologic examination was assessed using the intraclass correlation coefficient (ICC). Results: The median conspicuity scores were 5 at both scans, but the interquartile ranges were significantly different (5-5 at ultrafast vs. 4-5 at conventional, p < 0.001). Premenopausal status (odds ratio [OR] = 2.2, p = 0.048), non-mass enhancement (OR = 4.1, p = 0.001), moderate to marked BPE (OR = 7.5, p < 0.001), and shorter time to enhancement (OR = 0.9, p = 0.043) were independently associated with better conspicuity at ultrafast scans. Tumor size agreement between MRI and histopathologic examination was similar for both scans (ICC = 0.66 for ultrafast vs. 0.63 for conventional). Conclusion: Ultrafast DCE-MRI could improve lesion conspicuity compared to conventional DCE-MRI, especially in women with premenopausal status, non-mass enhancement, moderate to marked BPE or short time to enhancement.

A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports (DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

MRI-guided Wire Localization Open Biopsy is Safe and Effective for Suspicious Cancer on Breast MRI

  • Wang, Hai-Yi;Zhao, Yu-Nian;Wu, Jian-Zhong;Wang, Zheng;Tang, Jing-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1715-1718
    • /
    • 2015
  • Background: Magnetic resonance imaging of breast, reported to be a high sensitivity of 94% to 100%, is the most sensitive method for detection of breast cancer. The purpose of this study was to investigate our clinical experience in MRI-guided breast lesion wire localization in Chinese women. Materials and Methods: A total of 44 patients with 46 lesions undergoing MRI-guided breast lesion localization were prospectively entered into this study between November 2013 and September 2014. Samples were collected using a 1.5-T magnet with a special MR biopsy positioning frame device. We evaluated clinical lesion characteristics on pre-biopsy MRI, pathologic results, and dynamic curve type baseline analysis. Results: Of the total of 46 wire localization excision biopsied lesions carried out in 44 female patients, pathology revealed fourteen malignancies (14/46, 30.4%) and thirty-two benign lesions (32/46, 69.6%). All lesions were successfully localized followed by excision biopsy and assessed for morphologic features highly suggestive of malignancy according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category of MRI (C4a=18, C4b=17, C4c=8,C5=3). Of 46 lesions, 37 were masses and 9 were non-mass enhancement lesions. Thirty-two lesions showed a continuous kinetics curve, 11 were plateau and 3 were washout. Conclusions: Our study showed success in MRI-guided breast lesion wire localization with a satisfactory cancer diagnosis rate of 30.4%. MRI-guided wire localization breast lesion open biopsy is a safe and effective tool for the workup of suspicious lesions seen on breast MRI alone without major complications. This may contribute to increasing the diagnosis rate of early breast cancer and improve the prognosis in Chinese women.

Dynamic Contrast Enhanced MRI and Intravoxel Incoherent Motion to Identify Molecular Subtypes of Breast Cancer with Different Vascular Normalization Gene Expression

  • Wan-Chen Tsai;Kai-Ming Chang;Kuo-Jang Kao
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1021-1033
    • /
    • 2021
  • Objective: To assess the expression of vascular normalization genes in different molecular subtypes of breast cancer and to determine whether molecular subtypes with a higher vascular normalization gene expression can be identified using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI). Materials and Methods: This prospective study evaluated 306 female (mean age ± standard deviation, 50 ± 10 years), recruited between January 2014 and August 2017, who had de novo breast cancer larger than 1 cm in diameter (308 tumors). DCE MRI followed by IVIM DWI studies using 11 different b-values (0 to 1200 s/mm2) were performed on a 1.5T MRI system. The Tofts model and segmented biexponential IVIM analysis were used. For each tumor, the molecular subtype (according to six [I-VI] subtypes and PAM50 subtypes), expression profile of genes for vascular normalization, pericytes, and normal vascular signatures were determined using freshly frozen tissue. Statistical associations between imaging parameters and molecular subtypes were examined using logistic regression or linear regression with a significance level of p = 0.05. Results: Breast cancer subtypes III and VI and PAM50 subtypes luminal A and normal-like exhibited a higher expression of genes for vascular normalization, pericyte markers, and normal vessel function signature (p < 0.001 for all) compared to other subtypes. Subtypes III and VI and PAM50 subtypes luminal A and normal-like, versus the remaining subtypes, showed significant associations with Ktrans, kep, vp, and IAUGCBN90 on DEC MRI, with relatively smaller values in the former. The subtype grouping was significantly associated with D, with relatively less restricted diffusion in subtypes III and VI and PAM50 subtypes luminal A and normal-like. Conclusion: DCE MRI and IVIM parameters may identify molecular subtypes of breast cancers with a different vascular normalization gene expression.

Comparative Investigation of Single Voxel Magnetic Resonance Spectroscopy and Dynamic Contrast Enhancement MR Imaging in Differentiation of Benign and Malignant Breast Lesions in a Sample of Iranian Women

  • Faeghi, Fariborz;Baniasadipour, Banafsheh;Jalalshokouhi, Jalal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8335-8338
    • /
    • 2016
  • Purpose: To make a comparison of single voxel magnetic resonance spectroscopy (SV-MRS) and dynamic contrast enhancement (DCE) MRI for differentiation of benign and malignant breast lesions in a sample of Iranian women. Materials and Methods: A total of 30 women with abnormal breast lesions detected in mammography, ultrasound, or clinical breast exam were examined with DCE and SV-MRS. tCho (total choline) resonance in MRS spectra was qualitatively evaluated and detection of a visible tCho peak at 3.2 ppm was defined as a positive finding for malignancy. Different types of DCE curves were persistent (type 1), plateau (type 2), and washout (type 3). At first, lesions were classified according to choline findings and types of DCE curve, finally being compared to pathological results as the standard reference. Results: this study included 19 patients with malignant lesions and 11 patients with benign ones. While 63.6 % of benign lesions (7 of 11) showed type 1 DCE curves and 36.4% (4 of 11) showed type 2, 57.9% (11of 19) of malignant lesions were type 3 and 42.1% (8 of 19) type 2. Choline peaks were detected in 18 of 19 malignant lesions and in 3 of 11 benign counterparts. 1 malignant and 8 benign cases did not show any visible resonance at 3.2 ppm so SV-MRS featured 94.7% sensitivity, 72.7 % specificity and 86.7% accuracy.Conclusions: The present findings indicate that a combined approach using MRS and DCE MRI can improve the specificity of MRI for differentiation of benign and malignant breast lesions.

Prediction of Axillary Lymph Node Metastasis in Early Breast Cancer Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and Diffusion-Weighted Imaging

  • Jeong, Eun Ha;Choi, Eun Jung;Choi, Hyemi;Park, Eun Hae;Song, Ji Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.125-135
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) variables, for axillary lymph node (ALN) metastasis in the early stage of breast cancer. Materials and Methods: January 2011-April 2015, 787 patients with early stage of breast cancer were retrospectively reviewed. Only cases of invasive ductal carcinoma, were included in the patient population. Among them, 240 patients who underwent 3.0-T DCE-MRI, including DWI with b value 0 and $800s/mm^2$ were enrolled. MRI variables (adjacent vessel sign, whole-breast vascularity, initial enhancement pattern, quantitative kinetic parameters, signal enhancement ratio (SER), tumor apparent diffusion coefficient (ADC), peritumoral ADC, and peritumor-tumor ADC ratio) clinico-pathologic variables (age, T stage, multifocality, extensive intraductal carcinoma component (EIC), estrogen receptor, progesterone receptor, HER-2 status, Ki-67, molecular subtype, histologic grade, and nuclear grade) were compared between patients with axillary lymph node metastasis and those with no lymph node metastasis. Multivariate regression analysis was performed, to determine independent variables associated with ALN metastasis, and the area under the receiver operating characteristic curve (AUC), for predicting ALN metastasis was analyzed, for those variables. Results: On breast MRI, moderate or prominent ipsilateral whole-breast vascularity (moderate, odds ratio [OR] 3.45, 95% confidence interval [CI] 1.28-9.51 vs. prominent, OR = 15.59, 95% CI 2.52-96.46), SER (OR = 1.68, 95% CI 1.09-2.59), and peritumor-tumor ADC ratio (OR = 6.77, 95% CI 2.41-18.99), were independently associated with ALN metastasis. Among clinico-pathologic variables, HER-2 positivity was independently associated, with ALN metastasis (OR = 23.71, 95% CI 10.50-53.54). The AUC for combining selected MRI variables and clinico-pathologic variables, was higher than that of clinico-pathologic variables (P < 0.05). Conclusion: SER, moderate or prominent increased whole breast vascularity, and peritumor-tumor ADC ratio on breast MRI, are valuable in predicting ALN metastasis, in patients with early stage of breast cancer.

Ductal Carcinoma in situ with Multicystic Changes in a Patient with Interstitial Mammoplasty via Paraffin Injection: MRI and Pathological Findings

  • Park, Jiyoon;Woo, Ok Hee;Kim, Chungyeul;Cho, Kyu Ran;Seo, Bo Kyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.127-130
    • /
    • 2015
  • Direct injection of foreign material, such as liquid paraffin and silicone, into the breast can induce a foreign body granulomatous reaction and fibrosis, resulting in hard, nodular breast masses and architectural distortion that can mimic neoplasm. Conventional methods, including physical examination, mammography, and ultrasonography are of little use to differentiate between foreign body-induced mastopathy and breast cancer. In patients with foreign body injection such as breast augmentation, dynamic contrast enhanced MR imaging is an excellent imaging modality. Here, the authors report the MR imaging and pathological findings of ductal carcinoma in situ (DCIS) with multicystic changes in a 41-year-old woman with a previous history of interstitial mammoplasty by paraffin injection.

Role of MRI in Diagnostic Evaluation of Papillary Lesions of the Breast (유방의 유두상 병변의 진단에서 자기공명영상의 역할)

  • Lee, So-Mi;Kim, Hye-Jung;Gwak, Yeon-Joo;Lee, Hui-Joong;Jang, Yun-Jin;Shin, Kyung-Min;Park, Ji-Young;Jung, Jin-Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose : To evaluate the role of magnetic resonance imaging (MRI) in the diagnosis of papillary lesions of the breast. Materials and methods : Among 45 papillary lesions diagnosed at ultrasonography-guided core biopsy (USCB), 27 benign papillary lesions in 22 patients who underwent breast MRI were reviewed. The excsional biopsy was performed in 1-10 days after MRI was done. In MRI findings, lesions were considered suspicious if they show irregular, rim enhancement, or linear enhancement in morphologic evaluation, or washout enhancement pattern of delayed phase in dynamic enhancement characteristics. Diffusionweighted images were analyzed according to visibility of lesions. MRI findings were correlated with pathologic results at excisional biopsy. Results : At excisional biopsy, two lesions (9%) were diagnosed malignant in 22 benign papillary lesions without atypia by USCB and 4 (80%) were malignant in 5 benign papillary lesions with atypia by USCB. Among 18 lesions detected on MRI, 16 lesions showed suspicious findings on MRI, 11 lesions (69%) were diagnosed as benign and 5 (31%) were malignant. Among 12 lesions detected on diffusion weighted imaging, 10 lesions were diagnosed as benign and 2 were malignant. MRI findings were not significantly correlated with pathologic results at excisional biopsy. Conclusion : MRI findings were not useful to predict malignancy in benign papillary lesions diagnosed at USCB, because MRI findings of these were mostly suspicious (88.9%, 16/18). The benign papillary lesion should be included in the false positive lesion on breast MRI.