• 제목/요약/키워드: Duty Rate

Search Result 367, Processing Time 0.098 seconds

An Implementation of the RGB Remote Controller for LED Emotion Lighting of AtoN Facilities (항로표지 시설의 LED 감성조명을 위한 RGB 원격 콘트롤러의 구현)

  • Jeong, Yeong-Cheol;Choi, Jo-Cheon;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.475-480
    • /
    • 2012
  • This study on the methode is easied to distinguish with emotional visual lighting on AtoN facility using 3colors LED, and which is controlled to on-off switching of approach light in shore or harbor. The identification have easied to provide a differentiation between the AtoN facility of red and white light and surrounding light in harbor both sides. And the integrated controller have designed to left-right and serial sequential lighting system for harbor guidance using the GPS synchronous or timer. There is expectation effect that is prevent a confusion about distinguish of facility by ship's operator and to beautify a night scene of harbor, which is expressed to emotional identification lighting and variable color lighting on AtoN body by vertical layer color lighting using LED. In addition, the performance of AtoN is implemented to display with guidance light the harbor safety message by morse code lighting. Effectiveness of system is enhanced that age and power consumption reduce by candle alternated high light LED.

Performance analysis of an experimental plant factory

  • Ryu, Dong-Ki;Kang, Sin-Woo;Chung, Sun-Ok;Hong, Soon-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.395-403
    • /
    • 2013
  • Plant factory has drawn attention in many countries in the world due to capability of environmental control not only for better yield and quality, but also for increase in functional and medicinal components of the products. In this paper, an experimental plant factory was constructed for various tests under different environmental conditions, and the operations were evaluated. A production room was constructed with adiabatic materials with dimensions of $6,900{\times}3,000{\times}2,500$ mm ($L{\times}W{\times}H$). Four sets of $2,890{\times}600{\times}2,320$ mm ($L{\times}W{\times}H$) production frame unit, each with 9 light-installed beds and an aeroponic fertigation system, resulting in 36 beds, were prepared. Accuracy and response were evaluated for each environmental control component with and without crops. Air temperature, humidity, $CO_2$ concentration, light intensity, frequency, and duty ratio, fertigation rate and scheduling were controllable from a main control computer through wireless communication devices. When the plant factory was operated without crop condition, the response times were 8 minutes for change in temperature from 20 to $15^{\circ}C$ and 20 minutes from 15 to $20^{\circ}C$; 7 minutes for change in humidity from 40 to 65%; and 4 minutes for change in $CO_2$ concentration from 450 to 1000 ppm. When operated for 24 hours with crop cultivation; average, maximum, and minimum values of temperatures were 20.06, 20.8, and $18.8^{\circ}C$; humidity were 66.72, 69.37, and 63.73%; $CO_2$ concentrations were 1017, 1168, and 911 ppm, respectively. Photosynthetic Photon Flux Density was increased as the distance from the light source decreased, but variability was greater at shorter distances. Results of the study would provide useful information for efficient application of the plant factory and to investigate the optimum environment for crop growth through various experiments.

A Study on Working conditions and Characteristics of Dental Technicians (치과기공사의 근무 환경 및 업무특성 평가에 관한 연구)

  • Song, Jae-Sang;Hong, Young-Ho;Choi, Sang-Jun
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.379-390
    • /
    • 2011
  • Purpose: This study was conducted to improve the working conditions of dental technicians, through survey for working conditions related to perform one's duty, the extent of personal exposure to substances hazardous and complaint rate and factor of job stress and subjective symptom on musculoskeletal disorders. Methods: Using four types of structured questionnaires: social and demographic factor; the actual conditions of working space; working conditions; and characteristics of dental technicians, respondents filled in the questionnaires and the results were analyzed statistically. Results: The evaluation of comfort in working place found that satisfaction level on indoor noise was the lowest with 2.6 on a five-point scale and privacy space followed 2.8 point. In reasons for dissatisfaction with job, over workload ranked the highest by 25.4% and role overload had the highest by 39.5% in job stress factors. Based on the results, we could draw conclusion that dental technicians were unsatisfied with role overload and heavy workload a day. In reasons for musculoskeletal symptom prevalence, long-patient work was the highest by 24.1%. It was thought to cause dental technicians need deep procession and long-patient work due to the nature of their job. Conclusion: In conclusion, noise reduction and privacy space are required to improve job efficiency of dental technicians. In addition; we need to think of ways to increase the job satisfaction with adequate rest while deep procession and long-patient working.

Dimming Control of the LED Luminaire Emergency Exit Sign Operation using a Hybrid Super Capacitor of DC-DC Convertor (하이브리드 슈퍼커패시터 DC-DC 컨버터를 이용한 LED 비상 유도등 동작 디밍 제어)

  • Hwang, Lark-Hoon;Kim, Jin-Sun;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.220-229
    • /
    • 2017
  • In this paper, To take advantage a variety of DC power as the boost DC-DC converter design specifications through the inductor L and capacitor C through PSPICE to calculate the best estimate of the value. Boost DC-DC converter with a switch device using IRF840 and reverse recovery time Schottky diodes with excellent with constant current controller using D10SC6M and resistance can be configured to considering the Power LED Module was driven by the production. Converter's switching frequency is 50 kHz, the first Duty Rate was made to increase gradually depending on the value of the detection were, 10 % in the output voltage. As a result, the simulated Boost Power LED driver characteristics is in comparison with the design specifications, 5% or less as the error was approximated. Finally, when input 15 V were offered, a stable output 24 V were obtained. and Dimming Control through the adjustment of brightness and current consumption were possible.

Optimum Design of a Communication Protocol for Meteor Burst Communication (유성 버스트 통신을 위한 통신 프로토콜의 최적설계)

  • 권혁숭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.892-901
    • /
    • 2001
  • Despite of many advantages over conventional radio paths, application of the Meteor Burst Path in commercial communication system is so far limited to a few extent because of its low duty rate, which is, less than several percent at best. In order to get through maximum number of data bits during the short interval of each burst, which normally lives a fractions of a second, a sophisticated communication protocol is called for. In this paper, author introduces a communication protocol which can effectively locate and fetch burst signal by sending out periodic detection signal from master station and, with minimal delay, switch over to transmission states so as to put as many data bits through the detected burst as the burst length permits. By analyzing time period required for each transaction steps, the author derives optimal packet length for various bursts which assures to get a message string through in minimum delay. According to the analysis, the author proposes a protocol including a routine which automatically accesses average length of bursts at each environment and automatically adapt length of data packet so as to maximize data throughput under Riven burst conditions.

  • PDF

An Experimental and Modeling Study on the Oxidation Kinetics of Nitric Oxide over Platinum-based Catalysts (백금계 촉매상에서 산화질소(NO)의 산화반응속도에 관한 실험 및 모델링 연구)

  • Kim, Young-Deuk;Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.71-80
    • /
    • 2012
  • To improve the $NO_X$ conversion over a SCR (selective catalytic reduction) catalyst, the DOC (diesel oxidation catalyst) is usually placed upstream of the SCR catalyst to enhance the fast SCR reaction ($4NH_3+2NO+2NO_2{\rightarrow}4N_2+6H_2O$) using equimolar amounts of NO and $NO_2$. Here, a ratio of $NO_2/NO_X$ above 50% should be avoided, because the reaction with $NO_2$ only ($4NH_3+4NO+O_2{\rightarrow}4N_2+6H_2O$) is slower than the standard SCR reaction ($4NH_3+4NO+O_2{\rightarrow}4N_2+6H_2O$). In order to accurately predict the performance characteristics of SCR catalysts, it is therefore desired to develop a more simple and reliable mathematical and kinetic models on the oxidation kinetics of nitric oxide over a DOC. In the present work, the prediction accuracy and limit of three different chemical reaction kinetics models are presented to describe the chemicophysical characteristics and conversion performance of DOCs. Steady-state experiments with DOCs mounted on a light-duty four-cylinder 2.0-L turbocharged diesel engine then are performed, using an engine-dynamometer system to calibrate the kinetic parameters such as activation energies and preexponential factors of heterogeneous reactions. The reaction kinetics for NO oxidation over Pt-based catalysts is determined in conjunction with a transient one-dimensional (1D) heterogeneous plug flow reactor (PFR) model with diesel exhaust gas temperatures in the range of 115~$525^{\circ}C$ and space velocities in the range of $(0.4{\sim}6.5){\times}10^5\;h^{-1}$.

Study on the Performance Characteristics of Urea-SCR System in the ETC Test (ETC 모드에서 Urea-SCR 시스템의 성능 특성 연구)

  • Ham, Yun-Young;Choi, Dong-Seok;Park, Yong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.122-128
    • /
    • 2010
  • To meet the NOx limit without a penalty of fuel consumption, urea-SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, the performance characteristics of urea-SCR system with open loop control were assessed in the European Transient Cycle(ETC) for heavy duty diesel engine. The SCR inlet temperaure varied in the range of 200 to $340^{\circ}C$ in the ETC cycle. Open loop control calculated the urea flow rate based on the NOx and NSR map which gave for each combination of SCR inlet temperature and space velocity the normalized $NH_3$ to NOx stoichiometric ratio which resulted in a steady-state $NH_3$ slip of 20ppm. During the ETC cycle, the open loop control with the optimized NSR offset achieved NOx reduction of 80% while keeping the average $NH_3$ slip below 10ppm and maximum 20ppm. It was also found that NOx sensor was cross-sensitive to $NH_3$ and a control strategy for cross-sensitivity compensation was required in order to use a NOx sensor as feedback device.

Survey on the Industrial Safety & Hygiene Consultant System and It's Operational Issues (산업안전·위생지도사 제도 및 운영에 대한 인식도 조사연구)

  • Won, Jeung-Il;Park, Jong-Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.192-201
    • /
    • 2005
  • The Korean government had introduced the industrial safety & hygiene consultant(ISHC) system to improve worksite health and safety level by providing specialized industrial safety & hygiene(S&H) services in 1996. Despite of initial hopeful expectation it has been said that this plan might fail to settled down and maintain its purpose. This study was designed to investigate operational issues and problems concerning the ISHC system, that would direct the way of change and future role. Questionnaire were sent to ISHC, professional engineer, agencies for occupational injury prevention, S&H specialist in the corporation nationwide and totally 256 people responded to in having 62.7% of response rate. The result of this study were as follows; 1. One hundred and forty two cases of safety assessment and 27 cases of process safety reports were the six years' results since 1996 the ISHC program had first been introduced. This results showed that injury prevention activities of ISHC had been stagnant. 2. The 78.8% of respondents had negative opinion about injury prevention activities of ISHC program. 3. The operational problems of ISHC were lack of understanding of company about ISHC, low systematization of work items, duty overlapping with agencies for occupational injury prevention, low support by government. in order. 4. It was suggested that abolition of ISHC and promotion of professional engineer system should be considered. 5. To promote professional engineer system it was suggested that the professional engineer could conduct consulting service and ISHC should be integrated with the expert system.

Experiences with Pancreaticoduodenal Injuries at a Single Institute (단일 기관에서 치료한 췌 십이지장 손상에 대한 임상경험 보고)

  • Cho, Jin-Beom;Lee, Jun-Hyun;Lee, Do-Sang
    • Journal of Trauma and Injury
    • /
    • v.26 no.4
    • /
    • pp.266-272
    • /
    • 2013
  • Purpose: Although the duodenum and the pancreas are protected by surrounding organs and have a low probability of injury during trauma, the mortality and the morbidity due to complications is high. This report includes the pancreaticoduodenal injuries we observed that were treated at a single institute. Methods: The medical records of patients admitted to our institute between 2001 and 2012 for pancreaticoduodenal injury were retrospectively reviewed. Results: In our hospital, between 2001 and 2012, 15 patients were admitted for a pancreaticoduodenal injury. All patients experienced blunt trauma, 6 of whom were involved in traffic accidents and 9 of whom received injuries from physical assault. Most of the patients were men(13 of 15 patients, 86%) with a mean age of 23 years (range, 5?39 years). All patients were admitted to the emergency center and managed by the surgeons on duty. The mean value of the injury severity score was 22. The mortality rate was 6%(1 of 15 patients). Seven of the fourteen surviving patients(50%) had duodenal injury, 6 patients(42%) had a pancreatic injury, and 1 patient(7%) had a combined pancreaticoduodenal injury. The surgical procedures were targeted at damage control. Conclusion: In conclusion, we believe that damage control surgery is the optimal management for a pancreaticoduodenal injury.

A study on the haromnic attenuation of the BF Converter (BF 컨버터의 고조파 감쇠에 관한 연구)

  • 최태섭;안인수;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.8-15
    • /
    • 2000
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF(Boost Forward) converter with PWM-PFM(Pulse Width Modulation-Pulse Frequency Modulation) control technique to control DC output voltage, to remove the noise like harmonics at output voltage, and to control the input current with sinusoidal wave synchronized by the source voltage.To achieve the desired load voltage and improved PFC, we first implement current shaping control at the inverting stage and make the converted output DC voltage with forward converter. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. we control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally, we attenuated its harmonics and improved PF up to 0.96 using the current shaping technique.

  • PDF