• 제목/요약/키워드: Dust particle

검색결과 507건 처리시간 0.021초

부산지역의 겨울철 황사 발생 특성 (Characteristics of wintertime Asian Dust occurrence at Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제21권4호
    • /
    • pp.581-591
    • /
    • 2012
  • The purpose of this study was to analyze the characteristics of fine particles concentration and meteorological parameters, and long range transport of wintertime Asian dust at Busan. Also we studied occurrence frequency and tendency of wintertime Asian dust from 1961 to 2010 in Korea. Asian dust occurred most frequently in the spring, the next to winter in Korea. Wintertime Asian dust is steadily increasing recently. Asian dust in Busan was the most occurred in 2001 with 21 days, followed by 12 days in 2002, and 10 days in 2006. The annual mean frequency during the past 12 years(1999~2010) was 7.5 days, and it was two times more than that during the past 50 years(3.8 days). Wintertime Asian dust in Busan has occurred 6 episodes since 2008, and it all occurred in December except for 20 Feb. 2009. The highest concentration of wintertime Asian dust was recorded mostly at Hakjangdong and Jangrimdong which are industrial area. Maintenance time of Asian dust at Busan was from 1hr 30min to 9hr 20min, it was shorter than in the spring. It took from 10 to 15 hours move to Busan after Asian dust was first detected in Korea. Wintertime Asian dust originated from Gobi desert in Mongolia and inner Mongolia near China, except for 9 Dec. 2008 at Busan.

브레이크 캘리퍼에 장착한 비산먼지 포집기의 성능 평가 (Evaluation of the Performance of the Scattering Dust Collector Mounted on the Brake Caliper)

  • 김덕호;손병래
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.693-699
    • /
    • 2024
  • The main cause of scattering dust generated by transportation equipment such as automobiles was largely due to exhaust gas from internal combustion engines in the past, but it was generally recognized that non-exhaust causes such as abrasion of the tires or brake pads were low. Accordingly, scattering dust generated by exhaust gas has consistently existed in many studies, such as technological progress and related regulations, but research on non-exhaust is relatively insignificant, and the need for research on scattering dust generated by non-exhaust is emerging. In this study, a dust collector that can be easily mounted on a caliper to collect scattering dust generated by pad wear during the brake operation of an automobile was manufactured. In this study, we developed a dust collector that is easy to mount on calipers to collect scattering dust caused by pad wear during brake operation of automobiles. According to the installation of the manufactured dust collector, the performance of scattering dust by brake operation and the temperature change characteristics of calipers according to the structure of the dust collector were evaluated.

Chemically Aged Asian Dust Particles Proven by Traditional Spot Test and the Most Advanced micro-PIXE

  • Ma, Chang-Jin;Tohno, Susumu;Kang, Gong-Unn
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권2호
    • /
    • pp.114-123
    • /
    • 2016
  • A change in chemical compositions of Asian dust (AD) particles can dramatically alter their optical properties, cloud-forming properties, and health effects. The present study was undertaken to evaluate this aging of AD particles by means of two complementary methods (i.e., the traditional spot test and the most advanced micro-PIXE analytical technique) for single particle analysis. Size-classified particles were sampled at the rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD event and non-AD period in 2004. Sulfate was principally enriched on the particles in the size range of $7.65-10.85{\mu}m$ collected during AD event. The average number fraction of coarse particles ($>2.05{\mu}m$) containing chloride was 16.2% during AD event. Relatively low particles containing nitrate compared to those containing sulfate and chloride were found in AD event. Micro-PIXE elemental maps indicated that a large number of AD particles were internally mixed with man-made zinc. The highest peaks of EC and OC concentrations were appeared at $0.01-0.43{\mu}m$ particle aerodynamic diameter. High EC concentration in $PM_1$ was might be caused by the Saemangeum Seawall Project that was being conducted during our field measurement.

Characterization of depth filter media for gas turbine intake air cleaning

  • Park, Young Ok;Hasolli, Naim;Choi, Ho Kyung;Rhee, Young Woo
    • 한국입자에어로졸학회지
    • /
    • 제5권4호
    • /
    • pp.159-170
    • /
    • 2009
  • A depth filter medium was newly designed in order to achieve high collection of dust and low pressure drop in this work. Multilayer depth filter media consist of an upstream layer of highly porous structure which allows particles to pass through and to follow by one or more downstream layers to hold the particles inside the media. For each filter media, flat sheet and pleated module were made of newly developed depth filter media and filter media of commercial products. Commercial depth filter cartridge for gas turbine air intake cleaning were used as reference for filtration area and pleat geometry of pleated modules. This work attempts to evaluate and compare the newly developed depth filter medium and two commercial filter media in terms of filtration parameters such as air permeability, initial pressure drop, particle retention and pressure drop variation with dust loading. According to the close examination the newly developed depth filter showed better performance compared to the commercial depth filter media.

  • PDF

실내 공간별 미세먼지농도 비교 데이터의 시각화 (Visualization of the Comparison between Airborne Dust Concentration Data of Indoor Rooms on a Building Model)

  • 이상익;이진국
    • 한국주거학회논문집
    • /
    • 제26권4호
    • /
    • pp.55-62
    • /
    • 2015
  • The international concern on the inhalable fine dust is continuing to increase. In addition to the toxic properties of the fine dust itself, it can be more dangerous than other environmental factors since the dust pollution is hard to be detected by human sense. Although the information on outdoor air condition can be acquired easily, the indoor dust concentration is another problem because the indoor air condition is influenced by the architectural environment and human activity. It means occupants may be exposed to indoor dust pollution over a long period without being aware. Therefore the indoor dust concentration should be measured separately and visualized as an intuitive information. By visualizing, the indoor dust concentration in each space can be recognized practically in compare with the degree of pollution in adjacent spaces. Besides the visualization outcome can be used as base data for related research such as an analysis of the relation between indoor dust concentration and architectural environment. Meanwhile, with the development of network and micro sensing devices, it became possible to collect wide range of indoor environment data. In this regards, this paper suggests a system for visualization of indoor dust concentration and demonstrates it on an actual space.

낙하 충격에 의한 풍화토의 비산먼지 발생 특성 분석 (Analysis of dust emission characteristic by drop impact on decomposed granite soil)

  • 민슬기;손영환;박재성;노수각;봉태호
    • 한국농공학회논문집
    • /
    • 제56권3호
    • /
    • pp.39-45
    • /
    • 2014
  • Dust is mostly caused by human activity. The effect of natural factors on dust emission were studied in many research, but the little effort in researching artificial factors of dust emission. The object of study is to analysis dust emission characteristic by drop impact. Particle matter $10{\mu}m$ ($PM_{10}$) was measured by drop impact on paved soil with changing drop height, weight and drop size. Increasing drop height cause more $PM_{10}$ emission. Increasing drop weight cause more $PM_{10}$ emission but had limit weight for increasing dust emission. Because the exceed kinetic energy of drop weight penetrate the soil surface. The limit perimeter was exist that separating $PM_{10}$ emission aspect. Under limit perimeter, $PM_{10}$ emission was increasing while perimeter was increasing, but over limit perimeter showed the opposite aspect. Regression equations for estimating $PM_{10}$ with kinetic energy and perimeter were made under limit perimeter and over limit perimeter. The $R^2$ of those equations were 0.784, 0.743. The error has occurred between measured $PM_{10}$ and calculated $PM_{10}$ in the equation under limit perimeter. But using equation of case for over limit perimeter, PM10 can be estimated with kinetic energy and drop perimeter.

분진폭발의 입자거동을 고려한 화염전파속도의 예측 (Prediction of Flame Propagation Velocity based on the Behavior of Dust Particles)

  • 한우섭;한인수;최이락
    • Korean Chemical Engineering Research
    • /
    • 제47권6호
    • /
    • pp.705-709
    • /
    • 2009
  • 본 연구에서는 석송자 분진입자의 거동에 관한 실험적 연구결과를 바탕으로 한 분진화염 전파모델을 제시하였다. 화염전파속도는 분진농도와 함께 증가하여 석송자의 화학양론농도보다 높은 $170g/m^3$에서 최대로 나타났으며 $500g/m^3$까지 완만하게 감소 경향을 나타낸다. 농도 $47{\sim}200g/m^3$에 있어서, 분진입자속도는 화염전파속도에 비례하여 증가한다. 또한, 연소속도와 입자속도의 합이 화염전파속도에 근사한 값을 나타내고 있어, 분진농도에 따른 화염전파속도를 계산에 의해 추정이 가능하였으며, 입자의 거동이 분진의 화염전파속도를 이해하는데 유용하다는 것을 알 수 있었다.

An Effectiveness of Simultaneous Measurement of PM10, PM2.5, and PM1.0 Concentrations in Asian Dust and Haze Monitoring

  • Cho, Changbum;Park, Gilun;Kim, Baekjo
    • 한국환경과학회지
    • /
    • 제22권6호
    • /
    • pp.651-666
    • /
    • 2013
  • This study introduces a novel approach to the differentiation of two phenomena, Asian Dust and haze, which are extremely difficult to distinguish based solely on comparisons of PM10 concentration, through use of the Optical Particle Counter (OPC), which simultaneously generates PM10, PM2.5 and PM1.0 concentration. In the case of Asian Dust, PM10 concentration rose to the exclusion of PM2.5 and PM1.0 concentration. The relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration were below 40%, which is consistent with the conclusion that Asian Dust, as a prime example of the coarse-particle phenomenon, only impacts PM10 concentration, not PM2.5 and PM1.0 concentration. In contrast, PM10, PM2.5 and PM1.0 concentration simultaneously increased with haze. The relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration were generally above 70%. In this case, PM1.0 concentration varies because a haze event consists of secondary aerosol in the fine-mode, and the relative ratios of PM10 and PM2.5 concentration remain intact as these values already subsume PM1.0 concentration. The sequential shift of the peaks in PM10, PM2.5 and PM1.0 concentrations also serve to individually track the transport of coarse-mode versus fine-mode aerosols. The distinction in the relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration in an Asian Dust versus a haze event, when collected on a national or global scale using OPC monitoring networks, provides realistic information on outbreaks and transport of Asian Dust and haze.

연탄재 처리 환경미화원의 분진 및 호흡성 석영 노출 (Occupational exposure to dust and respirable quartz in coal briquettes ash handling worker)

  • 김부욱
    • 한국입자에어로졸학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study is to assess respirable crystalline silica (RCS) exposure levels in workers who collect and dispose used coal briquette ash (CBA) in sanitation companies that are subcontracted by one medium-sized local government on the collection of municipal household waste (MHW), and to analyze the quartz content in CBA. When the CBA powder that undergone specialized pretreatment in several steps were subjected to mineral identification and quantitative analysis using X-ray diffraction (XRD), it was found that quartz represented 18%, and in addition, mullite, and plagioclase were included. For two CBA collectors, samples were collected by the personal sampling evaluation method. After respirable dust was collected in accordance with the National Institute for Occupational Safety and Health 7500 method, the concentration of quartz was analyzed using XRD. Meanwhile, a portable real-time dust monitor (Sidepak AM520, TSI Inc., USA) was also used to observe the dust exposure level for each time zone and job task. The RCS exposure level of one worker was as high as 0.024 mg/㎥, which was the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLV) level. The other worker also exhibited a concentration of 0.013 mg/㎥, which was more than half of TLV. The Sidepak results revealed that the work of collecting CBA and loading it onto a vehicle was hardly exposed to the dust of a significant level. It was found, however, that the work of transferring the collected CBA to a container through a conveyor belt was exposed to a very high average respirable dust concentration of 2.238 mg/㎥. The results of this study confirmed that quartz, which is crystalline silica and a carcinogen, is contained in CBA, one of municipal household waste (MHW), in high concentration. It was also confirmed that workers are exposed to high RCS concentrations while transferring collected CBA into a container. Although each local government in South Korea handles CBA in different ways, it is imperative to investigate the CBA exposure level of sanitation workers and improve their working conditions.