• 제목/요약/키워드: Dust monitor

검색결과 65건 처리시간 0.022초

비산단지역 주민 피부 알레르기반응에 관한 연구 (A Study on the Allergen Skin Test Prevalence in the Residents of a Non-Industrial Area)

  • 안승철;김대선;유화연;권영민;주덕현
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.398-406
    • /
    • 2012
  • Objectives: In order to investigate the relation between environmental pollution and its effect on human health in large-scale industrial complex regions, monitoring studies have been conducted since 2003. The main purpose of this Gangneung study is to produce background data which can be compared with several large-scale industrial complex regions such as Ulsan, Sihwa, Banwol, Gwangyang, Yeosu, Pohang and Cheongju Daesan industrial complexes. Methods: In this Gangneung study, 1,007 local residents were recruited and the framework of this study was designed to evaluate and monitor health effects associated with low-level but long-term exposure to environmental pollutants. A survey was performed based on personal questionnaires, medical check-ups, and allergy skin prick tests for twelve common allergens. The authors reviewed the prevalence rate of skin allergens in Gangneung compared with in large-scale industrial areas. The results are summarized as follows. Results: The diagnosis prevalence and medical treatment prevalence of asthma were lower than in industrial complex regions, but allergic rhinitis was higher. The allergy skin test prevalence was 26.0% and the most common allergens were dust mites (D. pteronysinus 16.7% and D. farinae 16.3%). Conclusions: The positive findings of the skin prick test were similar with large-scale industrial complex regions in Korea. Further study is required to find the cause of the regional differences in skin prick prevalence.

Himawari-8/AHI 관측자료를 이용한 주요 대기 에어로솔 탐지 및 분류 방법 (Detection and Classification of Major Aerosol Type Using the Himawari-8/AHI Observation Data)

  • 이권호;이규태
    • 한국대기환경학회지
    • /
    • 제34권3호
    • /
    • pp.493-507
    • /
    • 2018
  • Due to high spatio-temporal variability of amount and optical/microphysical properties of atmospheric aerosols, satellite-based observations have been demanded for spatiotemporal monitoring the major aerosols. Observations of the heavy aerosol episodes and determination on the dominant aerosol types from a geostationary satellite can provide a chance to prepare in advance for harmful aerosol episodes as it can repeatedly monitor the temporal evolution. A new geostationary observation sensor, namely the Advanced Himawari Imager (AHI), onboard the Himawari-8 platform, has been observing high spatial and temporal images at sixteen wavelengths from 2016. Using observed spectral visible reflectance and infrared brightness temperature (BT), the algorithm to find major aerosol type such as volcanic ash (VA), desert dust (DD), polluted aerosol (PA), and clean aerosol (CA), was developed. RGB color composite image shows dusty, hazy, and cloudy area then it can be applied for comparing aerosol detection product (ADP). The CALIPSO level 2 vertical feature mask (VFM) data and MODIS level 2 aerosol product are used to be compared with the Himawari-8/AHI ADP. The VFM products can deliver nearly coincident dataset, but not many match-ups can be returned due to presence of clouds and very narrow swath. From the case study, the percent correct (PC) values acquired from this comparisons are 0.76 for DD, 0.99 for PA, 0.87 for CA, respectively. The MODIS L2 Aerosol products can deliver nearly coincident dataset with many collocated locations over ocean and land. Increased accuracy values were acquired in Asian region as POD=0.96 over land and 0.69 over ocean, which were comparable to full disc region as POD=0.93 over land and 0.48 over ocean. The Himawari-8/AHI ADP algorithm is going to be improved continuously as well as the validation efforts will be processed by comparing the larger number of collocation data with another satellite or ground based observation data.

고속도로 톨게이트 부스 내 공기 중 PM10의 노출평가 (Exposure Assessment of PM10 in Expressway Toll Booths)

  • 남미란;피영규
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.151-157
    • /
    • 2018
  • Objectives: This study was conducted in order to evaluate $PM_{10}$ concentrations at eight highway tollgate booths from July to September 2017. Methods: A total of 16 samples were collected from eight toll booths. Each $PM_{10}$ sample was collected using a 37 mm PTFE filter attached to a Personal Environment Monitor. Results: The geometric mean concentrations of $PM_{10}$ in the toll booths was $83.51{\mu}g/m^3$. The mean $PM_{10}$ concentrations measured on freight roadways were much higher than those of measured on general roadways($102.46{\mu}g/m^3$ and $68.05{\mu}g/m^3$, respectively). $PM_{10}$ was revealed to be higher in the morning($105.59{\mu}g/m^3$) than at dawn or in the afternoon($71.26{\mu}g/m^3$ and $61.22{\mu}g/m^3$, respectively). The mean $PM_{10}$ concentration in toll booths ventilated through an air conditioner was higher than that for those using a window or no ventilation. The rate of exceeding the Ministry of Environment Maintenance Limit($200{\mu}g/m^3$) was 6.25%, and the rate of exceeding the Ministry of Labor Recommended Limit($150{\mu}g/m^3$) was 12.5%. Conclusions: In order to protect the health of toll booth workers exposed to airborne dust, it is necessary to check the exposure level from indoor air quality on a regular basis and to manage it appropriately according to the results.

육계사 내 작업자의 미세먼지 노출량 현장모니터링 (Concentrations of Particulate Matter Exposed to Farm Workers in the Broiler Houses)

  • 서효재;오병욱;김효철;신소정;서일환
    • 한국농공학회논문집
    • /
    • 제62권5호
    • /
    • pp.27-37
    • /
    • 2020
  • As domestic meat consumption increases, the broiler production industry has been larger and denser. The concentration of particulate matter (PM) and harmful gases generated is also increasing inside livestock house. However, the current research status of PM exposed to farm workers and the health effects are in the early stage. To understand PM concentration affecting workers in the broiler house, field monitoring was conducted according to its size distributions. Concentrations of PM10, PM2.5, and TD (Total Dust) were monitored using personal air samplers with teflon filter during working and moving periods considering the ventilation systems of 6 broiler houses. The purpose of this study is to monitor the PM concentration in the experimental broiler houses operated by forced ventilation system generally used in Korea and to evaluate the regional concentrations through airflow pattern. The PM concentrations were increased from inlet to outlet vents resulting in 1,872 of TD, 1,385 of PM10, and 209 ㎍/㎥ of PM2.5, respectively. The TD and PM10 concentrations were increased when the workers and broilers were moving. Among them, the particle size that occupied the largest amount of PM was 13.75 ㎛. These results suggest that personal protection equipments are important to reduce the health effect from PM inhalation.

충주지역 주민 피부 알레르기 반응율에 관한 연구 (A Study on Allergen Skin Test Prevalence Among the Residents of Chungju City as a Non-industrial Area)

  • 김대선;이보은;남상훈;안승철
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.367-375
    • /
    • 2014
  • Objectives: The main purpose of this study is to produce background data which can be compared with several large-scale industrial complex regions. Methods: The framework of this study was designed to evaluate and monitor health effects associated with low-level and long-term exposure to environmental pollutants. In this study, 1,009 local residents were recruited in the city of Chungju using personal questionnaires, medical check-ups, and allergen skin-prick tests for 12 common allergens. The prevalence rate of skin allergens was reviewed together with that from large-scale industrial areas. Results: The diagnosis prevalence and medical treatment prevalence of asthma was 5.6% and 1.7%, respectively. Allergic rhinitis was 25.4% and 16.7%, allergic dermatitis was 16.6% and 9.9% and allergic conjunctivitis was 18.7% and 7.9%, respectively. These results were similar with those of industrial complexes. The prevalence of allergen skin-prick test was 16.4% and the most common allergen was dust mites (27.9-31.6%). This result was lower than those of the industrial complexes (22.5-39.9%) and Gangneung (18.2-24.7%). Conclusion: Further study is required to find the cause of the regional differences in skin prick prevalence.

드론을 이용한 대기환경정보 수집장치 개발 및 응용 연구 (Development of atmospheric environment information collection system using drone)

  • 김남호
    • 스마트미디어저널
    • /
    • 제7권4호
    • /
    • pp.44-51
    • /
    • 2018
  • 본 연구는 이동 및 휴대가 용이함과 더불어 지표로 부터 0~1km 높이의 특정한 위치에서의 환경정보를 수집하기 위하여 드론을 이용하였으며, 드론에 장착할 수 있는 대기환경 정보 수집기를 만들어 대기 중의 환경정보를 모니터링 하는 방안을 제안한다. 기상적인 요소로 온도와 습도를 측정하고, 환경적인 요소로 미세먼지와 $CO_2$를 관측하여 정상적인 값을 받을 수 있도록 하였다. 측정을 통하여 특정 기업, 공단, 지역의 대기가스 배출현황을 모니터링 함으로써 오염요인을 줄이는 정책수립에 도움을 줄 수 있도록 하였다. 그 동안 배기가스 검출은 굴뚝에 설치된 구멍에 검시자가 직접 접근하여 측정하다보니 안전상 많은 위험에 노출되었으나 제안하는 드론을 이용하게 되면 안정성 확보와 더불어 광범위한 정보수집이 가능하여 보다 정확한 정보수집과 다양한 산업적 활용이 가능함을 확인하였다.

화력 발전기 보일러 내부 작업자 위치 모니터링 시스템 개발 (The Monitoring System for Location of Workers Inside a Thermal Power Plant Boiler)

  • 송규;윤찬녕;신영하;신정훈;한성희;장동영
    • 한국안전학회지
    • /
    • 제36권5호
    • /
    • pp.71-78
    • /
    • 2021
  • There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power plants workers are always exposed to risk during overhaul periods owing to the narrow space and significant dust inside the boiler. Therefore, it is essential to develop a safety monitoring system that is suitable for operating in this type of environment. In this study, we developed not only a worker three-dimensional (3D)-location monitoring system that can monitor and record the entry/exit of workers, their 3D-location, and fall accidents but also a method to secure the working environment and operation efficiency. This system comprises of a worker tag, which was equipped with an inertial measurement unit, a barometric pressure sensor, and a Bluetooth low energy (BLE), and the tags were given to each worker. In addition, the location of workers inside the boiler was measured using a pedestrian dead reckoning (PDR) method and BLE beacons. The location data of the workers tag were transmitted to the integrated database (DB) server through a gateway, and to the administrator monitoring system. The performance of the system was demonstrated inside an actual thermal power plant boiler, and the accuracy and reliability of the system were verified through a number of repeated tests. These results provide insights on designing a new system for monitoring enclosed spaces.

산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현 (Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site)

  • 장문석;이응혁
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

수확, 경운정지, 파종, 정식, 순지르기 작업에서 발생하는 PM10 노출 특성 (PM10 Exposure Characteristics During the Harvesting, Plowing, Sowing, Planting, and Decapitation Tasks of Agricultural Workplaces in South Korea)

  • 정원건;서민태;김효철
    • 한국산업보건학회지
    • /
    • 제32권2호
    • /
    • pp.137-145
    • /
    • 2022
  • Objectives: This study aimed to identify PM10 mass concentration levels and conduct peak identification during five tasks in agricultural works. Methods: We investigated five agricultural tasks in 12 farms, which were harvesting, plowing, sowing, planting, and decapitation. All samples were measured by using the portable aerosol spectrometer(PAS 1.108) and the aerosol monitor(SidePak AM520). The collected data were compared with the national PM10 concentrations. They were calculated to descriptive statistics, independent t-test, or ANOVA, and the peak identification on time series graph. Results: The ten investigated farms showed no significant difference with the national PM10 concentrations, but the two greenhouses(AM, 143.31, 85.16 ㎍/m3) showed significant difference(p<0.05). As a result of the peak identification, the harvesting tasks showed repeated peak occurrence with the background concentration level of about 50 ㎍/m3. For plowing and sowing tasks, the peak occurred intermittently when the working was conducted near the sampling sites. Among the five tasks, the arithmetic mean of the harvesting task was 138.84±294.71 ㎍/m3, which was significantly higher than the other tasks(p<0.05). In addition, the case of using a tractor was higher than the case of not using the tractor(p<0.05), and the driver's seat showed the highest concentration(AM, 95.81 ㎍/m3). Conclusions: Works in greenhouses might have exposure to PM10, while outdoor works is similar to general atmospheric PM10 concentration levels. However, there is a possibility of intermittent exposure to high concentrations of PM10 depending on the characteristics of agricultural tasks.

1인 가구 안전사고 예방을 위한 Home IoT 센서 시스템 (Home IoT Sensor System for Prevent Safety Accidents in Single-person Household)

  • 백창대;김한호;차현석;손형민;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.397-399
    • /
    • 2021
  • 사회적으로 1인 가구의 증가와 Home IoT 기술의 발전에 따라 주거 환경의 편의성 개선이 중요시된다. 또한 'COVID-19'에 의한 실내 활동 증가에 따라 1인 가구의 주거 편리성을 위한 제품 개발이 요구되고 있다. 이러한 추세로 그 전보다 현재 주거 환경과 상호작용이 수월해졌으며, 이에 따라 Home IoT 기술 발전의 필요성이 대두되고 있다. 따라서 본 논문은 온도, 습도, 미세먼지와 같이 실내 환경 유지에 필요한 정보를 모니터링하여 사용자와 상호작용 할 수 있도록 하였으며, 가스 누출 및 화재와 같은 안전사고 예방에 필요한 IoT 센서를 탑재하여 증가하는 실내 활동에 안전성을 향상하는 시스템을 제안하였다.

  • PDF