• 제목/요약/키워드: Dust collector

검색결과 102건 처리시간 0.025초

루버 집진기의 성능특성 (Performance Characteristics of Louver Dust Collectors)

  • 우상희;김종범;박통일;육세진;권순박;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제12권1호
    • /
    • pp.11-20
    • /
    • 2016
  • A large amount of wear dust generated during train operation is a major dust source in urban railway tunnels. To check possibility of a louver dust collector for the removal of dust in the railway tunnel, five louver dust collector models were designed and their performance was tested in a wind tunnel. JIS Z 8901 Class 8 dust was used as a test dust. Pressure drop and particle collection efficiency were evaluated with the face velocity ranging from 1 m/s to 4 m/s. At this low velocity range, particle collection efficiency of the louver dust collector was found to be insensitive to air velocity and design parameters. Pressure drop was under 40 Pa, and $PM_{10}$ and $PM_{2.5}$ collection efficiencies were approximately 50% and 30%, respectively.

사이클론 집진장치의 내부 온도 변화에 따른 집진효율에 관한 전산해석적 연구 (Numerical Study on the Effect of the Internal Temperature Distribution in the Cyclone Dust Collector)

  • 현대근;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제10권4호
    • /
    • pp.155-162
    • /
    • 2014
  • The internal temperature will change depending on operation conditions and material of cyclone dust collector. This study compares the results of collection efficiency and temperature distribution on the different heat flux at wall of dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $600^{\circ}C$. Because of the difference of outer vortex and inner vortex temperature, the collection efficiency will reduce with the increase of heat flux, showed the highest collection efficiency at heat insulation.

산업 환경에서의 집진기에 대한 RF모니터링 시스템 구현 (Implementation of RF Monitoring System for the Dust Collector in Industrial Environments)

  • 이성엽;이광희;고봉진
    • 한국항행학회논문지
    • /
    • 제18권5호
    • /
    • pp.513-517
    • /
    • 2014
  • 본 논문에서는 대기환경의 악화 방지와 개선을 위하여 현재 수동으로 관리되고 있는 집진기 관리시스템을 대신하여 무선을 이용하여 집진기를 관리하는 RF 모니터링 시스템을 설계하고 구현하였다. 제안한 시스템은 산업현장 내 다수의 집진기에 대한 가동시간, 전력량, 차압값 등을 무선으로 모니터링 하여 관리자의 PC에 표시하고 저장할 뿐만 아니라 장애 발생 시 이를 관리자의 휴대폰으로 알려 줌으로서 고부가가치의 집진기 모니터링 시스템의 구현이 가능하다. 따라서 본 논문에서 구현한 RF 모니터링 시스템을 통하여 대기배출원관리시스템(SEMS)에 각 집진기의 정보를 기록함에 있어서 불필요한 손실을 줄일 수 있다.

연마장비용 사이클론 집진장치 설계 (Development of Sweeping Machine with Cyclone Dust Collector)

  • 진태석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.911-913
    • /
    • 2013
  • 본 논문에서는 선박의 외벽 청소용으로 사용되는 연마장비에 사이클론 집진방식을 채용한 연마장비를 개발을 위한 최적화된 설계를 위한 기본적인 메카니즘과 설계를 소개하고자 한다. 사이클론 방식은 공기의 유입 및 유출 속도 및 압력에 따른 미립자 등을 분리하는 기능을 하게 되는데 본 연구에서는 이러한 연마장비설계를 위한 사이클론 집진기의 효율과 압력, 유입 공기속도에 따른 설계방법을 소개하고 일부 실험결과를 제시하도록 한다.

  • PDF

도시철도 터널 미세먼지 제거용 하이브리드형 집진장치의 성능평가 (Performance Evaluation of a Hybrid Dust Collector for Removal of Airborne Dust in Urban Railway Tunnels)

  • 우상희;김종범;장홍량;권순박;육세진;배귀남
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.433-439
    • /
    • 2017
  • 도시철도터널은 전동차 운행으로 바닥 먼지가 비산되거나 새로 발생된 마모 먼지로 오염되고 있다. 전동차가 운행하면서 이러한 부유 먼지를 제거하기 위해서 관성집진기인 배플과 전기집진기로 구성된 하이브리드형 집진장치를 개발하였다. 하이브리드형 집진장치의 유량과 집진효율은 서로 반비례하므로, 유량과 집진효율의 관계를 파악하기 위해 2가지 배플 모델을 제작하여 성능을 평가하였다. 유속이 3.4 m/s인 A1 모델을 장착한 집진장치의 $0.5{\mu}m$ 이상인 입자의 집진효율은 30% 이상이었고, 유속이 4.7 m/s인 A2 모델의 경우 20% 이상이었다. 인가전압이 13 kV일 때 1시간 동안 A1 모델 집진장치의 $PM_{10}$ 집진량은 253 mg, A2 모델의 경우 242 mg으로 추정되었다.

Dust accumulation effect on solar thermal energy systems performance

  • Alsaad, Mohammad A.
    • Advances in Energy Research
    • /
    • 제3권3호
    • /
    • pp.157-165
    • /
    • 2015
  • This research investigates the effect of natural dust accumulation on the glass cover of solar thermal energy conversion systems. Four similar, locally manufactured, flat plate solar collectors are used. All collectors are South oriented with tilt angle of $40^{\circ}$. The glass cover of one collector is kept clean of dust during the experimental period while the second collector is cleaned at the beginning of each month. The third collector is cleaned every two months while the fourth collector is kept un-cleaned throughout the experimental period of four months. The calculated parameters are the solar heat gain rates and the corresponding values of the thermal efficiency. The result of the present work indicates that the percentage of fractional reduction of the useful heat gain rate due to dust accumulation during a period of one and two months is 11.4% and 17.0%, respectively. The percentage decrease of thermal efficiency during the same duration periods is 4.0% and 6.1%, respectively. The percentage of fractional reduction of the useful heat gain rate due to dust accumulation during a period of three and four months is 27.8% and 31.9%, respectively. The percentage decrease of monthly thermal efficiency during the same duration period is 10.2% and 11.3%, respectively.

사이클론 집진장치의 내부온도에 따른 외부 소용돌이와 집진효율의 관계 (Relationship between the Outer Vortex and the Collection Efficiency with respect to Temperatures in the Cyclone Dust Collector)

  • 현대근;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제11권2호
    • /
    • pp.47-55
    • /
    • 2015
  • This study compares the results of collection efficiency of difference gas temperature in cyclone dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $600^{\circ}C$ and $1000^{\circ}C$. As the temperature decreases, the average velocity of outer vortex and collection efficiency is increased, showed the highest collection efficiency at $20^{\circ}C$. It can be inferred smooth flow in cyclone dust collector is difficult because air viscosity increases as temperature increases. The power required at $1000^{\circ}C$ is almost 18 times greater than that of $20^{\circ}C$ to get the similar collection efficiency.

물 가스 개질 고속선회 소각로에 관한 융합연구 (Convergent Study on the Hydro-Gas Reforming Cyclo-Incinerator)

  • 한두희
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.231-236
    • /
    • 2020
  • 물 개질반응 고속선회 소각로 시험 설비를 제작하였다. 개질 반응실과 연소실은 직접 연결이 되게 하였다. 소각로와 집진 장치는 일체형으로 만들어 2중 격벽식 공기 냉각 구조로 만들었다. 송풍기를 집진장치 내부에 내장하여 공간적으로 효율성을 향상시켰다. 집진부의 옆에 부착된 다수의 집진통을 이용하여 분진을 수거하여 백필터가 별도로 필요없는 축류 유동형 다단식 집진장치를 적용하였다. 배출되는 가스 중 다이옥신을 측정한 결과 기준치 이하의 결과를 얻었다. 배출가스와 중금속을 측정한 결과 환경기준치 이하의 결과를 얻었다.

플라즈마 절단기용 집진기의 내부유동 분포에 관한 수치해석 (A Numerical Analysis on Flow Distribution in the Fume Collector for Plasma Cutting Machine)

  • 이중섭;서정세;윤강로;박영호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1361-1366
    • /
    • 2009
  • This study is to see the internal flow for the plasma cutting fume collector. Plasma cutters are widely used in the canning industry and Fume cause the device because it will affect the performance of the design of dust collector. Therefore, to determine the distribution of the internal flow using CFD and Solver was used for calculated with commercial CFD code STAR-CCM+. The results show that design of chamber was incorrect after passed the filter for exhaust to the fan. And the location of the duct to the influx of dust collector and the design was incorrect. In addition, an array of filter was also inappropriate. As a result, present fume collector need to improvement.

  • PDF