• Title/Summary/Keyword: Dust collection efficiency

Search Result 108, Processing Time 0.031 seconds

Development of the Dual Cyclone System for a High Efficient Vacuum Cleaner (사이클론 집진 원리를 적용한 진공청소기 개발에 관한 연구)

  • Lee, Jae-Keun;Lee, Jung-Eun;Kim, Seong-Chan;Cho, Min-Chul;Hyun, Choong-Nam;Kwack, Dong-Jin;Lim, Kyung-Suk;Lee, Sung-Hwa;Yang, Byung-Sun;Ji, Heon-Pyung;Jeong, Hoi-Kil;Park, Deog-Bae;Liu, Benjamin Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.644-649
    • /
    • 2000
  • A new cyclone system for the vacuum cleaner to collect dusts has been studied experimentally and numerically to meet the constant suction power, hygienic exhaust and a reduction of maintenance cost. The cyclone system of the vacuum cleaner consists of twin cyclones for improving dust collection efficiency. The first. cyclone catches large dust particles and the second one having two separated flows to decrease pressure drop collects small dust particles. The optimal design factors such as dust collection efficiency, pressure drop, and cut-size are investigated from the experimental results by the Taguchi method. Cyclone cleaner systems designed in this study has a good Performance taking into account the dust collection efficiency of 93% and the cut-size of $1.6{\mu}m$ in mass median diameter at the flow rate of 1 CMM. The cyclone vacuum cleaner showed the potential to be an effective method to collect dusts generated in the household.

  • PDF

A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate (황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거)

  • 서정민
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

Performance Evaluation of a Hybrid Dust Collector for Removal of Airborne Dust in Urban Railway Tunnels (도시철도 터널 미세먼지 제거용 하이브리드형 집진장치의 성능평가)

  • Woo, Sang Hee;Kim, Jong Bum;Jang, Hong Ryang;Kwon, Soon Bark;Yook, Se-Jin;Bae, Gwi-Nam
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.433-439
    • /
    • 2017
  • Urban railway tunnels are polluted by resuspension of deposited bottom dust or newly generated wear dust. A hybrid type dust collector consisting of a baffle and an electrostatic precipitator was developed to remove these types of airborne dust when trains are running in the tunnel. Since dust collection efficiency of the hybrid dust collector is inversely proportional to the airflow rate, the relationship between airflow rate and dust collection efficiency was experimentally investigated for two baffle models. Collection efficiencies for dust larger than $0.5{\mu}m$ for the hybrid dust collector model A1, operated at 3.4 m/s, were greater than 30%; those for the hybrid dust collector model A2, operated at 4.7 m/s, were higher than 20%. When the applied voltage was 13 kV, the amounts of $PM_{10}$ collected with model A1 and model A2 dust collectors were estimated at $253{\mu}g$ and $242{\mu}g$ per hour, respectively.

A study on cleaning performance of particles on collection plates using an electrodynamic screen (전기역학적 스크린을 이용한 집진판 표면 위 입자 세정성능 연구)

  • Yunhui Joe;Dongho Shin;Younghun Kim;Inyong Park;Sang Bok Kim;Gunhee Lee;Bangwoo Han
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.63-76
    • /
    • 2023
  • An electrostatic precipitator (ESP) has a low pressure drop and a high collection efficiency but its collection efficiency can be reduced due to dust accumulation on the collection plates during long-term operations. In order to maintain the initial dust collection efficiency, it is necessary to periodically clean the collection plates. The common cleaning methods are using physical impacts or water sprays. These cleaning methods can lead to damage to the collection plate or generate wastewater. Herein, we implemented an electrodynamic screen (EDS) for ESP cleaning and evaluated its surface cleaning performance of particles. The EDS is an electrostatic system that can electrostatically repel particles on surfaces, allowing it to clean the ESP without causing damage and wastewater generation. Our evaluation included the analysis of the effects of AC voltage characteristics, electrode configuration and environmental conditions on the cleaning performance of the EDS with the aim of achieving effective surface cleaning. It has been demonstrated that activating the EDS cleans up to 65% of the particles on the surface, which indicates about 94% of our target cleaning zone.

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.

  • PDF

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF

Filtration Characteristics of Paticulate Matter at Bag Filters Coated with PTFE Membrane During Off-Line Pulsing (PTFE membrane이 코팅된 여과백의 off-line 탈진시 미세먼지 집진 특성)

  • Kim, Joung-Hun;Moon, Il-Shik;Hwang, Min-Young;Kim, Ryang-Gyoon;Ko, Daekwun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.7
    • /
    • pp.391-402
    • /
    • 2017
  • Particulate matter becomes an important issue in the environmental society recently so that it is necessary to evaluate that the commercial application of baghouse systems for effective control of fine particulates is viable. A laboratory-scale baghouse experimental apparatus with filter bags made of PTFE felt or PTFE felt coated with PTFE membrane is used to investigate the filtration performances of fine particulates. Experiments by changing filtration velocity, inlet dust concentration, and average dust particle size show that the dust collection efficiency becomes higher at lower filtration velocity, higher inlet dust concentration and larger average dust particle size. The total pressure drop through the filter media and dust layer becomes higher at higher filtration velocity and higher inlet dust concentration. The dust collection efficiency is higher and the pressure drop is lower at a baghouse with filter bags coated with PTFE membrane than that without membrane coating. From the result that the dust collection efficiency of $PM_{2.5}$ in a reasonable filtration velocity range during off-line pulsing at a baghouse with PTFE felt bag filters coated with PTFE membrane is as high as 99.99%, it is confirmed that the use of baghouse is an effective measure to control the fine particulates.

Investigation of the Concentration of PM2.1 & PM10 and Alveolar Deposition Ratio (미세먼지(PM10)와 초미세먼지(PM2.1)의 농도와 폐포 침착율 조사)

  • Kim, Seong Cheon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.126-133
    • /
    • 2019
  • Objectives: In this study, a nine-stage cascade impactor was used to collect dust, and the concentration of $PM_{2.1}$ & $PM_{10}$ and alveolar deposition ratio were investigated. Methods: This study was conducted at Kunsan National University from May to June 2016. A nine-stage Cascade Impactor was used to analyze the concentrations of fine and ultrafine dust and to estimate the alveolar deposition rate by particle size of atmospheric dust particles. The pore size of each stage of the collector used in this study gradually increased from F to 0, with the F-stage as the last stage. Results: The mass fraction of PM showed a bimodal distribution divided into $PM_{2.1}$ & $PM_{10}$ based on $2.1-3.1{\mu}m$. The average mass fraction of particulate matter in the range of $2.1-3.1{\mu}m$ was 44%, and the area occupied by $PM_{2.1}$ was similar. Therefore, the Gunsan area is considered to be a region where there are similar effects from anthropogenic and natural sources. Conclusion: Dust collecting efficiency increased with the stage of collecting fine dust, and the efficiency of collection was very low at the stage of collecting ultra-fine dust. The seasonal overall efficiency of the Cascade Impactor was 44% in spring and 37.4% in summer, and the average overall efficiency was 40.7%. The alveolar deposition rate of $PM_{2.1}/PM_{10}$ during the sampling period was estimated to be about 75% deposited in the alveoli.

Numerical Study of Cyclone Dust Collector (싸이클론 집진기의 수치해석적 연구)

  • 전영남;엄태인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.43-53
    • /
    • 1996
  • Numerical simulation was performed for the 3-dimensional flow filed of gas and particle phase for cyclone dust collector. FVM(Finite Volume Method) was employed for gas phase. The flow was solved suing the k-.varepsilon. epsilon turbulence model. The particle exit at the bottom of the cone was treated as a solid wall in this model because the gas flow through the effective dust exit is usually insignificant. The major parameters considered in this study was vortex finder diameter, effective dust exit diameterm vortex finder length, inlet type for dimension performance. Particle trajectory calculations were made for three different, particle sizes of 1, 25 and 50 .mu.m. The results obtained from this study give some physical insight of dust particle collection mechanism together with the indication of the collection efficiency. The simulation results were in generally good agreement with empirical knowledge. The application of this kind of computer program looks promising as a potential tool for the design of cyclone and determination of optimum operating condition.

  • PDF

Performance of Automotive Cabin Air Filter for Passenger Cars (승용차용 Cabin Air Filter의 성능)

  • 박영옥;구철오;임정환;김홍룡;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.279-287
    • /
    • 1996
  • Pressure drop and fractional collection efficiency of automotive cabin air filters were examined to obtain the basic data for the development of high performance domestic cabin air filters. Pressure drop of MA-V100 was higher than that of VF-V100, and it increased with the air flow rate. VF-V100 had longer time to rise the critical pressure drop than that MA-V100 had. Total collection efficiency of MA-V100 for initial and dust loaded conditions was higher than that of VF-V100. Also, fractional collection efficiency of MA-V100 for the fine particles was higher than that of VF-V100. Particla size distribution for the minimum collection efficiency ranged from 0.02 $\mu$m to 0.04 $\mu$m for MA-V100 and it ranged from 0.02 $\mu$m to 0.15 $\mu$m for VF-V100.

  • PDF