• Title/Summary/Keyword: Durability Performance Evaluation

Search Result 403, Processing Time 0.028 seconds

An Experimental Study on the Durability Evaluation of Polymer Cement Restoration Materials for Deteriorated Reinforced Concrete Structures (성능저하된 철근콘크리트구조물 폴리머시멘트계 보수용 단면복구재의 내구성 평가에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Jae-Hwan;Cho, Bong-Suk;Park, Jong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.123-130
    • /
    • 2006
  • The duties of the restorative materials are to bear up against stress and to protect reinforcement corrosion. So the restorative materials are estimated by various kinds of strength, permeability and etc, But, in case of existing performance evaluation of restorative materials, because various deterioration factors are separately acted, the system of performance evaluation is different from that of combined deterioration of real structure and it is difficult to evaluate the exact performance of restorative materials. In this study, to evaluate Performance of restorative materials, we compare their korea standard properties in terms of compressive and bending strength and permeability of water and air with real durability for carbonation, salt damage and actual reinforcement corrosion like ratio of corrosion area. weight reduction and corrosion velocity of steel bar under environment of combined deterioration. The results showed that strength and permeability of restorative materials are similar but their resistance to carbonation, salt damage and actual reinforcement corrosion are very different.

An Experimental Study on the Durability and Reinforcement Corrosion of Polymer Cement Based Repair Material (폴리머시멘트계 단면복구재의 내구성 및 철근부식특성에 관한 실험적 연구)

  • Kim Young Sun;Kim Young Duck;Na Chul Sung;Cho Bong Suk;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.487-490
    • /
    • 2005
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the data of indoor durability test and the data of the long term exposure test under the coast are accumulated and analyzed. As a result of the indoor test, durability of repair material was more superior to that of plain concrete, but as a result of investigating and evaluating exposure test at 30 month of exposure age under the coastal environment, the difference in electric potential and the reinforcement corrosion at place replaced with repair material are found.

  • PDF

Antifungal Durability Evaluation of Sanitary Sealant (방균실란트의 방균지속성 평가)

  • Seo, YeonWon;Jung, Jin-young;Ahn, Myung-Su;Kim, Sung Hyun;Bae, Keesun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.65-67
    • /
    • 2014
  • There are many elastomeric joint sealant applications in construction such as structural glazing, weatherproofing and insulating glass fabrication etc. Each sealant joints require unique durability functions to perform well through building life cycle. Elastomeric joints in bathroom and kitchen is one of areas which require durable sealing. In this application, anti fungal durability is proprietary function of sealant during building life cycle. Premature failure of anti fungus resistance of sealant is putting big stresses to general contractor as well as the inhabitants due to costly rework and poor sanitation. Accordingly, when chemists design a product, they must take into account various parameters not only formulation components also test conditions in order to have long term fungal durability. This paper reviews several biocide options with various industry standards for fungus resistance performance to suggest making new test method for construction sealant industry.

  • PDF

Evaluation of Durability Performance of Fly Ash Blended Concrete due to Fly Ash Replacement with Tire Derived Fuel Ash (타이어 고무 애쉬 치환에 따른 플라이애쉬 혼입 콘크리트의 내구성능 성능 평가)

  • Kwon, Seung-Jun;Yoon, Yong-Sik;Park, Sang-Min;Kim, Hyeok-Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.647-653
    • /
    • 2016
  • In the paper, durability performance in FA (Fly Ash) blended concrete is evaluated considering replacement of FA with TDFA (Tire Derived Fuel Ash) from 3.0% to 12%. TDFA is a byproduct from combustion process in thermal power plant, where chopped rubber is mixed for boiling efficiency. This is the 1st study on application of TDFA to concrete as mineral admixture. For the work, concrete samples containing 0.5 of w/b (water to binder) ratio and 20% replacement ratio of FA are prepared. With replacing FA with TDFA to 12%, durability performance is evaluated regarding compressive strength, carbonation, chloride diffusion, and porosity. The results of compressive strength, carbonation, and porosity tests show reasonable improvement in durability performance to 12% replacement of TDFA. In particular, clear decreasing diffusion coefficient is observed with increasing TDFA replacement due to its packing effect. Concrete containing TDFA can be effective for durability improvement when workability is satisfied in mixing stage.

A Study on Safety Evaluation of Wheel Using Roller Rig Tester (주행시험기를 이용한 차륜의 안전성 평가에 관한 연구)

  • Ham, Young Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.591-595
    • /
    • 2015
  • The roller rig tester for safety performance evaluation of wheel derailment is a test facility which can give the test load condition to the test wheel, similar to the actual dynamic condition in actual running condition. This study describes the evaluation result on the durability of the resilient wheel equipped with the ring damper and the damping material, and installed in the half part of a full scaled bogie in combination with the primary spring when it rotates under the dynamic condition. The evaluation result on durability of resilient wheel after load test of 2 million cycles shows that the safety of wheel is not affected by the applied load in visual inspection and nondestructive test, however, in the bolt used for fastening the ring damper to the wheel the loosening was found. Accordingly the use of self-locking nut and washer is recommended.

Evaluation of Mechanical Properties and Durability of Fabric Concrete Binder for Emergency Repair (기상재해 대응 긴급보수용 패브릭 콘크리트 혼합물의 역학적 특성 및 내구성능 평가)

  • Jeon, Sang-Min;Jo, Sung-Mun;Oh, Ri-On;Kim, Hwang-Hee;Cha, Sang-Sun;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.23-31
    • /
    • 2020
  • Recently, meteorological disasters have been increasing by climate change, excessive rainfall, and landslide. The purpose is to develop new fabric concrete that can prevent and recover from damages because some of areas are vulnerable to meteorological disaster. Specifically, this technology can minimize time and space constraint when repairing the concrete structure and installing a formwork. The structure of fabric concrete is a mixture of fabric concrete and a high-speed hardened cement, Silica sand, wollastonite mineral fiber, fabric material and waterproof PVC fabric. In this study, the ratio of mechanical properties and durability of the fabric concrete mixture was evaluated by deriving the binder: silica sand mix ratio of the fabric concrete mixture and substituting part of the cement amount with wollastonite mineral fiber. Best binder in performance evaluation: Silica sand mix ratio is 6: 4 and the target mechanical performance and durability are the best when over 15% wollastonite binder is replaced by silicate mineral fiber.

Development of Durability Design for Railroad Concrete Structures Exposed to Marine Environment Considering Time Dependency (시간의존성을 고려한 해안가 철도 콘크리트 구조물에 대한 내구성 설계 기법의 개발)

  • Song, Ha-Won;Pack, Seung-Woo;Lee, Son-Ho;Kwen, Jin-Su;Lee, Hyun-Jung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1431-1438
    • /
    • 2007
  • This paper presents a refined design model for current railroad design code on concrete structures exposed to marine environment. A time-varying diffusion coefficient(D) as well as surface chloride$(C_S)$ and chloride threshold level$(C_{lim})$ are studied. Averaging value of the D with time over exposed duration were used to refined durability design model to consider time dependent characteristic of D. The values for $C_S$ and $C_{lim}$ for the seashore in Korea revised for realistic durability design. The proposed model was verified by the so-called performance-based durability design, which is widely used in recent durability design code. Results show that the current standard specification underestimates durability performances of concrete structures exposed to marine environment, so that the cover depth design using current durability evaluation in the standard specifications is very much conservative. Thus, it is found that proposed durability design models for the railroad design code for railway concrete structures can be used effectively for service life design of concrete structures in marine environment.

  • PDF

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure (지붕용 톱코팅재의 내구성 향상에 관한 성능 및 평가방법에 관한 기초적 연구)

  • Park, Jin-Sang;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.517-520
    • /
    • 2006
  • The waterproofing of Building on the roof has been exposed more underground or the other part of waterproofing than environmental factor(solar heat, UV, salt, acid rain, wind, temperature, snow, rain, etc.) or physical factor. So it must be have a waterproofing performance and it has a special technique for the maintaining of concrete durability. Therefore, exposed waterproof layer has to protected from UV, solar heat, rain and the outside environment also, to endurance durability methods spread face plate topcoat material on the waterproof layer. But, actuality faceplate waterproof layer of topcoat materials are unbearable to UV, solar heat and moisture etc. and it doesn't have adhesion with waterproof layer in the middle. So it happens to crack, separating and heaving etc. Therefore, in the study, we will suggest that using of the exposed roof waterproof layer topcoat materials test method manage rooftop waterproof layer for the durability and the stability.

  • PDF

Evaluation of Penetration Reinforcing Agent for Aging Preventing & Recovery Capacity of Concrete (표면침투보강제의 콘크리트 열화 방지 및 회복성능 평가)

  • Cho, Myeng-Suk;Song, Young-Chul;Kim, Do-Gyeum;Lee, Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.321-324
    • /
    • 2006
  • The latest concrete has showed that the deterioration of durability has been increased by the damage from salt, carbonation, freezing & thawing and the others. Therefore, it is needed to protect durability and performance according to the appropriate materials and methods in the concrete structures. In general, several types of polymer and silicate are used as protecting deterioration agents of concrete structures, but these agents have many problems because of low durability and properties. In this study, It developed the deterioration restraining agent using polycondensed silicate and monomer that can block a deterioration cause such as CO2 gas, salt and water from the outside and enhance waterproofing ability by reinforcing the concrete surface when applying it to concrete structures. Also, it evaluated improving concrete performance using a deterioration restraining agent.

  • PDF

Evaluation on the Durability of PVA Fiber Reinforced Mortar for Repair (PVA 섬유 보강 보수 모르타르의 내구성 평가)

  • Koh, Kyung-Taek;Ryu, Gum-Sung;Lee, Jang-Hwa;Kang, Su-Tae;Yoon, Pil-Yong;Kim, Jin-Su
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.621-624
    • /
    • 2006
  • In this study, the repair method using PVA fiber reinforced mortar evaluated on durability performance. Test of salt injury, carbonation, freezing-thawing, chemical attack, permeability was performed As for the test results, it was found that durability performance of the repair method using PVA fiber mortar showed more better than the existing repair method. Therefore, appling on the repair method using PVA fiber reinforced mortar, the repaired concrete structures can be increased to service life.

  • PDF