• Title/Summary/Keyword: Durability Evaluation

Search Result 960, Processing Time 0.034 seconds

A Study on the Evaluation Method of Structural Safety(Durability) for the Safety Diagnosis of Apartment Housing (공동주택 재건축 안전진단 구조안전성(내구성) 평가 방법에 관한 고찰)

  • Kim, Hong-Seop;Kim, Eun-Young;Jeon, Jun-Seo;Choe, Gyeing-Cheol;Lee, Mun-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.313-314
    • /
    • 2023
  • This paper summarized the safety diagnosis method in the field of durability among the structural safety suggested in the safety diagnosis manual of the reconstruction project and analyzed the safety diagnosis case. It is expected to be a reference material for safety diagnosis in the field of durability by pointing out cases that are wrong during existing safety diagnosis and cases where diagnostics are likely to make errors.

  • PDF

Development of Early Evaluation System for Concrete Quality, Construction and Maintenance (콘크리트 품질ㆍ시공ㆍ유지관리의 조기판정시스템 개발)

  • 손용우;이증빈;최미라;박봉수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.517-526
    • /
    • 2004
  • In the resent years, the early evaluation of concrete quality, construction and maintenance has been considered as all is of major concern due to the increase of loading and the degradation of structures related with time. This paper presents evaluation of structural safety performance using measured data of construction, on the basis of a field measurements for the prevention of unreliable concrete works. Measurements analyzed in this paper are early quality condition and performance assessment, serviceability performance by cracks and deflection, rating performance by loading, durability performance by chloride attack and carbonation. Thus, a quantitative assessment model of resistance capacity was developed here to meet the requirement for deteriorated concrete structures. The model focuses on damage mechanical of concrete structures deteriorated by initial damage factors for concrete quality and environment factors such as chloride and carbonation attacks. These results could provide useful information for concrete structures interested in design, construction and maintenance.

  • PDF

Reliability Evaluation for Hinge of Folder Devices Using ESPI

  • Kyungyoung Jhang;Minkwan Hyun;Lee, Taehun;Seokwon Chang
    • International Journal of Reliability and Applications
    • /
    • v.5 no.1
    • /
    • pp.15-24
    • /
    • 2004
  • Folder type electronic devices have hinge to support the rotational motion of folder. This hinge is stressed by the rotational inertia moment of folder at the maximum open limit position of folder. This stress is repeated whenever the folder is open, and it is a cause of hinge fracture. In this paper, the reliability evaluation for the hinge fracture in the folder type cellular phone is discussed. For this, the durability testing machine using crank-rocker mechanism is developed to evaluate the life cycle of the hinge, and the degradation after repetitions of opening and shutting is evaluated from the deformation around the hinge, where the deformation is measured by ESPI (electronic speckle pattern interferometer). Experimental results showed that ESPI was able to measure the deformation of hinge precisely, so we could monitor the change of deformation around the hinge as the repetition number of folder open is increased.

  • PDF

Evaluation of Exterior Durability of Domestic Plywood for Temporary Construction (국산(國産) 가설재용(假說材用) 합판(合板)의 옥외(屋外) 내구성(耐久性) 평가(評價))

  • Kim, Gyu-Hyeok;Jo, Jae-Sung;Song, Ki-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.20-27
    • /
    • 1994
  • Water repellent preservative (WRP) treated and untreated, small-sized specimens prepared from semiwater resistant, water resistant, and tegofilm-overlaid plywood were exposed to outdoor weathering for one year. Exterior durability of specimens was evaluated on the basis of changes in dynamic modulus of elasticity, degree of delamination, modulus of elasticity, modulus of rupture, and glueline shear strength. Among untreated specimens, tegofilm-overlaid plywood showed the best outdoor durability, and durability between semiwater resistant and water resistant plywood was similar. Although WRP treatment increased the durability of all types of plywoods, the effect of treatment on the increase in durability for semi water resistant plywood was not distinct. Accordingly, it can be concluded that semi water resistant plywood, which is used for temporary construction such as concrete formwork in our country, can not be inadequate for exterior use, regardless of WRP treatment. The bending strength and glueline shear strength of untreated water resistant plywood measured after weathering for one year did not exceed the minimum value specified by Korean Standard (KS), thereby the outdoor use of water resistant plywood was not desirable without WRP treatment. Exterior durability between treated water resistant plywood and untreated tegofilm-overlaid plywood was very similar. This result suggests that if an exposed plywood surface is treated with WRP regularly water resistant plywood can be used for temporary construction. This suggestion, however, needs to be investigated. In summary, semiwater resistant plywood cannot be used for temporay construction regardless of WRP treatment. Water resistant plywood can be used only with WRP treatment. Comparing the cost of tegofilm-overlaid plywood to costs of water resistant plywood and WRP treatment, however, it can be concluded that use of tegofilm-overlaid plywood for temporay constrution is strongly suggested from the point of view of both outdoor durability and costs.

  • PDF

Characteristics of Pore Structure and Chloride Penetration Resistance of Concrete Exposed to Freezing-Thawing (동결융해 작용을 받은 콘크리트의 공극구조 및 염화물 침투저항 특성)

  • Choi, Yoon Suk;Won, Min Sik;Yi, Seong Tae;Yang, Eun Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.73-81
    • /
    • 2012
  • Concrete structures are commonly exposed to freezing-thawing condition. This freezing-thawing action changes the pore structure of concrete, and it can reduce the durability of concrete. In this study, the change of the internal pore structure and durability of concrete due to freezing-thawing action are investigated. According to results, the excellent durability records were reported by the existing evaluation methods for all mixes. However, the pores, 50~100nm size in diameter, are increased in concrete specimens exposed to freezing-thawing action, and the chloride penetration resistance was significantly reduced. The linear relationship between pore structure and chloride penetration resistance was shown in water cured concrete. Meanwhile, the linear relationship was decreased when concrete is exposed to freezing-thawing condition. It is desirable to review the criterion of durability evaluation for concrete specimens exposed to freezing-fthawing and chloride attack condition, simultaneously.

Durability Evaluation and Defect Pattern Analysis in Railway Bridge Through Field Investigation (현장조사를 통한 철도 고가교 구조물의 내구성 평가 및 결함 패턴 분석)

  • Kwon, Seung Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.10-20
    • /
    • 2013
  • Because of the defect in design, damage in using period, and deterioration in long term exposure to severe environmental condition, degradation of performance in RC (Reinforced Concrete) structures has occurred. This paper contains durability performance evaluation in railway bridges which covers eight districts through field investigation. For the target structures, durability performance is evaluated and the critical problems in use are derived. Additionally, service lifes for the deteriorated structures are evaluated through Durability-Environment index method based on the results from field investigation, and the results are compared with those from the condition assuming the structures without defect, damage, and deterioration. The target structures which consist of RC T girder, PSC girder, RC box, and Rahmen are investigated and the critical damage patterns are derived. They are evaluated to be cracks in PSC girder end, flexural cracks in PSC girder, crack around EPT anchor, and flexural cracks in RC T girder and RC box. The reasons for the critical patterns are also investigated. This study can be utilized for the repair planning considering the different district and the structure types.

Construction Method and Durability Evaluation of Mock-up Test for Bobsleigh Track (실물크기형 봅슬레이 트랙 Mock-up Test 시공방법 및 내구성 평가)

  • Lee, Kyeo-Re;Han, Seung-Yeon;Nam-Gung, Kyeong;Yun, Kyong-Ku
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.315-323
    • /
    • 2016
  • This study examined the durability and method for making a mockup of bobsled tracks for constructing a bobsled stadium, which is a sport in the Winter Olympics. As bobsleigh games are very fast and dangerous, a safety design for players and a precise construction using highly efficient shotcrete is necessary. Moreover, a general molding construction is difficult because bobsleigh tracks are composed of various curves and slopes, and it is necessary to construct them using high-strength and high durability materials. The developed method for making a mockup and performing durability evaluation of bobsleigh tracks through this research will be applied in the construction of the 2018 Pyeongchang Winter Olympics Sliding centre and bobsleigh tracks using domestic techniques.

Durability Evaluation of Air-Cooled Proton Exchange Membrane Fuel Cells Stacks by Repeated Start-Up/Shut-Down (시동/정지반복에 의한 공랭식 고분자연료전지 스택 내구성 평가)

  • YOO, DONGGEUN;KIM, HYEONSUCK;OH, SOHYEONG;PARK, KWON-PIL
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.5
    • /
    • pp.315-323
    • /
    • 2021
  • The air-cooled proton exchange membrane fuel cells (PEMFC) stacks, which is widely used in small-sized PEMFC, have a problem in that durability is weaker than that of the water-cooled type. Because the cathode is open to the atmosphere and the structural problem of the air-cooled stack, which is difficult to maintain airtightness, is highly likely to form a hydrogen/air boundary during start-up/shut-down (SU/SD). Through the accelerated durability evaluation of the 20 W air-cooled PEMFC stack, the purpose of this study was to find out the cause of the degradation of the stack and to contribute to the improvement of the durability of the air-cooled PEMFC stack. In this study, it was possible to evaluate durability in a relatively short time by reducing 20-30% of initial performance by repeating SU/SD 1,000 to 1,200 times on an air-cooled PEMFC stack. After disassembling the stack, each cell was divided into two and the performance analysis showed that the electrode degradation was more severe in the anode outlet membrane electrode assembly (MEA), which facilitates air inflow as a whole, than in the inlet MEA. It was shown that the cathode Pt was dissolved/precipitated to deteriorate the polymer ionomer inside the membrane.

Evaluations and Attitudes of Workers in Low Temperature Storages of Discount Stores Toward their Uniforms (대형 할인 마트 저온 창고 작업자의 유니폼에 대한 평가와 태도)

  • Yoo, Hwa-Sook
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.538-547
    • /
    • 2011
  • The purpose of this study was to examine the evaluations and attitudes of workers in low temperature storages of discount stores toward their uniforms by carrying out a field study and a survey. The effects of evaluation attributes on their attitudes were also investigated. In this study, the reference of the evaluation of uniforms was based on the concepts of serviceability, which implies the fitness for purpose of products and consists of durability, care, comfort and aesthetic appearance. Of 400 questionnaires, 253 of them were used for data analysis. The data were analyzed by descriptives, t-test, factor analysis, reliability test and regression analysis with SPSS 12.0. As a result, it showed that workers have set low values on easy care, physiological comfort, aesthetic appearance and durability among the evaluation attributes. In attitudes toward the uniforms, emotional attitude was negative whereas behavioral attitude positive. It appeared that the evaluation attributes had influence on the attitude toward the uniforms and esthetic appearance among the attributes had the biggest effects on the workers' attitude. In conclusion, it was found that the discount store uniforms should be improved in the aspects of easy care and physiological comfort, and focused on the esthetic appearance for workers' positive attitudes to their uniforms.