• Title/Summary/Keyword: Duplex structure

Search Result 111, Processing Time 0.025 seconds

Development of Cube Satellite's Communication System Using Commercial UHF Half-Duplex Antenna (상용 반이중 통신방식 UHF대역 송·수신겸용 안테나를 적용한 큐브위성의 통신시스템 구현)

  • Chae, Bong-Geon;Ha, Heon-Woo;Jang, Su-Eun;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.6
    • /
    • pp.522-528
    • /
    • 2014
  • A UHF/VHF full-duplex communication using monopole and dipole antenna has been widely used for cube satellite applications. This kind of communication system requires a dedicated structure panel for antenna integration, which is the one of the disadvantages of the conventional communication system from the accommodation point of view considering the extremely limited volume of the cube satellite. In this study, to maximize the accommodation efficiency of the cube satellite, the commercial UHF half-duplex antenna combined with buck converter for communication modes transition has been considered in the communication system design. Its effectiveness has been verified through link budget analysis based on the antenna specifications and satellite's operation conditions. In addition, the antenna deployment mechanism for the synchronous release of multi-antennas has also been introduced.

Self-Interference Cancellation and Turbo Equalizer Design for the Single-band Full Duplex System using Single Antenna (단일 안테나를 사용하는 단일대역 전이중 통신을 위한 자기간섭신호제거와 터보 등화기 설계)

  • Choi, Jinkyu;An, Changyoung;Ryu, Heung-Gyoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.7-17
    • /
    • 2015
  • In this paper, we propose a single antenna SSD(simultaneous single band duplex) system using turbo equalizer. The proposed system communicates simultaneously on single band. That is the proposed system is full-duplex system. The proposed system uses balanced feed network circuit to improve isolation in single antenna structure. Also, the proposed system uses RF(radio frequency) cancellation and digital cancellation to cancel self-interference. Additionally, the proposed system uses turbo equalizer to equalize ISI(inter-symbol interference) by harsh multipath fading and to collect bit errors by residual self-interference signals. By using turbo equalizer, the proposed system guarantees QoS(quality of service). In this paper, we uses Simulink simulation program to analyze performance of the proposed system. The simulation results confirm that proposed system can communicate simultaneously by using balanced feed network, RF cancellation, digital cancellation and turbo equalizer in harsh multipath channel on single band.

Weathering Performance Evaluation of Duplex Coating Systems of Thermal Spraying and Painting using Corrosion Test (부식실험에 의한 금속용사와 도장의 복합피복방식법의 내후성능평가)

  • Kim, In Tae;Kim, Ho Seob;Kien, Dao Duy;Jun, Je Hyeong;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.97-108
    • /
    • 2016
  • Thermally sprayed metals or organic coatings is often used in corrosion protection of steel structures. Duplex coating systems of thermally sprayed metal in combination with organic coating are selected as a new generic type of coatings on steel structures under the highly corrosive environments. In this study, three types of corrosion tests were carried out on four types of thermal sprayed specimens with sealing: zinc, zinc-15%aluminum alloy, aluminum and aluminum-5%magnesium alloy, four types of duplex coated specimens; thermally sprayed metals in combination with paint of acrylic urethane, and painted specimens. NORSOK M-501, Wet/dry cyclic seawater tests and outdoor exposure tests of nine types of specimens were conducted. From the corrosion test results, weathering performance of them were presented.

Block Shear Behavior of Cold-Formed Duplex Stainless Steel (STS329FLD) Welded Connection with Base Metal Fracture (냉간성형 듀플렉스계 스테인리스강(STS329FLD) 용접접합부 모재 블록전단파단 거동)

  • Hwang, BoKyung;Kim, TaeSoo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.4
    • /
    • pp.157-165
    • /
    • 2019
  • Recently, lean duplex stainless steel, STS329FLD with less nickel (reduced to 0.5~1.5%) has been developed as a substitute of austenitic stainless steel (8%~10.5% nickel in STS304) and included in Korean standards (KS). This paper investigates the block shear behavior of cold-formed duplex stainless steel (STS329FLD, nominal plate thickness of 1.5mm) fillet-welded connection with base metal fracture. Main variables are weld lengths in the longitudinal and the transverse directions of applied force ranged from 20mm to 50mm. As a result, specimens failed by typical block shear facture (the combination of gross section tensile fracture and shear fracture or shear yielding) and ultimate strength of the specimens got higher with the increase of weld length. Block shear fracture strengths predicted by current design specifications (KBC2016/AISC2016 and EC3) and existing proposed equations for welded connections by Topkaya, Oosterhof & Driver and Lee et al. were compared with test strengths. KBC2016/AISC2016 and EC3 design specifications underestimated block shear strength of STS329FLD welded connections by on average 24%, 29%, respectively and Oosterhof & Driver, Topkaya and Lee et al's equations overestimated the ultimate strength of the welded connection by the range of 3% to 44%.

Effect of Aging on the Microstructure and Mechanical Properties in Super Duplex Stainless Steel (슈퍼 2상 스테인리스강의 미세조직 및 기계적 성질에 미치는 시효의 영향)

  • Kim, Su-Chun;Kang, Chang-Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.40-45
    • /
    • 2009
  • With the increase in the annealing temperature, the volume fraction of austenite phase increased and the volume fraction of ferrite phase decreased. In compliance with the addition of N, not only the volume fraction of austenite phase was increased but also the austenite structure was made larger. Volume fraction of ${\sigma}$ phase was increased by decreasing of the volume fraction of ferrite phase, with the increase in the aging time and in compliance with the addition of N. As increasing in volume fraction of ${\sigma}$ phase, tensile strength and hardness increased, while elongation and impact value decreased. Elongation slowly decreased and impact value rapidly decreased at the early stage of aging. By the added N, tensile strength, elongation, hardness and impact value was increased.

Structural and Dynamic Studies of the Central Segments in the Self-complementary Decamer DNA Duplexes d(ACGTATACGT)2 and d(ACGTTAACGT)2

  • Park, Jin-Young;Lee, Joon-Hwa;Choi, Byong-Seok
    • BMB Reports
    • /
    • v.31 no.1
    • /
    • pp.89-94
    • /
    • 1998
  • The structures of the self-complementary decamer duplexes, $d(ACGTATACGT)_2$ (TATA-duplex) and $d(ACGTTAACGT)_2$, (TTAA-duplex) has been obtained in solution by proton NMR spectroscopy and restrained molecular dynamics. The duplexes are essentially B-type, with distortions apparent at the TATA and TTAA steps. Theses distortions and their effects on dynamics have been investigated by the measurement of imino proton exchange time of the base-pairs. The unusual opening kinetics of central A T base-pairs could be correlated to the abnormal structural properties of the corresponding sequences.

  • PDF

A Study of Weld Fusion Zone Phenomena in Austenitic Stainless Steels(2) - Effects of Nitrogen on Microstructural Evolution and Hot Cracking Susceptibility GTA Welds in STS 304 - (오스테나이트계 스테인리스강 용접부의 금속학적 현상에 관한 연구(2) - STS 304 용접부 조직특성 및 고온균열 감수성에 미치는 질소의 영향 -)

  • 이종섭;김숙환
    • Journal of Welding and Joining
    • /
    • v.18 no.1
    • /
    • pp.59-69
    • /
    • 2000
  • The purpose of the present study was to investigate weld metallurgical phenomena such as primary solidification mode, microstructural evolution and hot cracking susceptibility in nitrogen-bearing austenitic stainless steel GTA welds. Eight experimental heats varying nitrogen content from 0.007 to 0.23 wt.% were used in this study. Autogenous GTA welding was performed on weld coupons and the primary solidification mode and their microstructural characteristics were investigated from the fusion welds. Varestraint test was employed to evaluate the solidification cracking susceptibility of the heats and TCL(Total Crack Length) was used as cracking susceptibility index. The solidification mode shifted from primary ferrite to primary austenite with an increase in nitrogen content. Retained delta ferrite exhibited a variety of morphology as nitrogen content varied. The weld fusion zone exhibited duplex structure(austenite+ferrite) at nitrogen contents less than 0.10 wt.% but fully austenitic structure at nitrogen contents more than 0.20 wt.%. The weld fusion zone in alloys with about 0.15 wt.% nitrogen experienced primary austenite + primary ferrite solidification (mode AF) and contained delta ferrite less than 1% at room temperature. Regarding to solidification cracking susceptibility, the welds with fully austenitic structure exhibited high cracking susceptibility while those with duplex structure low susceptibility. The cracking susceptibility increased slowly with an increase in nitrogen content up to 0.20 wt.% but sharply as nitrogen content exceeded 0.20 wt.%, which was attributed to solidification mode shift fro primary ferrite to primary austenite single phase solidification.

  • PDF

Study on the Brittle Crack Arrest Property for 9% Ni Steel by Duplex ESSO test (Duplex ESSO 시험법에 의한 9% Ni강 취성 균열정지 특성 연구)

  • Kim, Young Kyun;Oh, Byung Taek;Yang, Young Chul;Yoon, Ihn soo;Kim, Jae Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.47-54
    • /
    • 2020
  • A brittle fracture is one of the source of structural damage and can bring a fatal accident. The inner shell of LNG storage tank should be designed and applied to construction by ensure that no brittle crack will occur under -162℃ condition. In point of view of fracture mechanics brittle fracture in the structure could be referred as crack initiation and crack arrest. It should be designed no crack initiation. However, in the unlikely event of a brittle fracture occurring, a back-up function of arresting the brittle crack should be included for the design. In this paper investigated the characteristics of 9% Ni steel thick plates of having a capability of arresting brittle cracks under the thickness of 33 mm, 37mm, 40 mm. First, charpy test has performed to evaluate the fundamental brittle impact fracture property of 9% Ni steel under the temperature of 24℃, -162℃ and -196℃. In addition, Duplex ESSO tests were also performed under -196℃ to evaluate the capability of crack arrest for 9% Ni steel. From the experiments results, it was confirmed that all the thickness of 9% Ni steel plates exhibits sufficient brittle crack arrest fracture toughness for the application of LNG storage tank as a inner shell.

The Variation of TiAl microstructure with Ni, Mn alloying and Heat Treatment (Ni, Mn 첨가와 열처리에 따른 TiAl 미세 조직 변화)

  • Moon, J.T.;Lee, S.H.;Han, B.S.;Shin, B.M.;Lee, Y.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.3
    • /
    • pp.181-187
    • /
    • 1997
  • TiAl intermetallic compound was candidated for the application to the high temperature materials such as a gas turbine exhaust valve in the automobile. However, this material dose not have ductility allowing to machinability to product. To improve the ductility, many researches conduct alloy design and heat treatment methods. We observed that the microstructure of TiAl varied with Ni, Mn elements as well as a heat treatment condition. In the case of Ni element addition, the TiAlNi intermetallic compound was precipitated at the grain boundary. When the heat treatment temperature increased from $1000^{\circ}C$ to $1300^{\circ}C$, the TiAlNi intermetallic compound was uniformly dispersed on the matrix. In the case of Mn element addition, the mixed duplex structure of ${\gamma}$-TiAl and lamellar(TiAl/$Ti_3Al$) was obtained with $1250^{\circ}C$ and $1300^{\circ}C$ heat treatment for 1 hour. When the heat treatment temperature increased from $1250^{\circ}C$ to $1300^{\circ}C$, the lamellar domain of the duplex structure was transformed near-lamellar structure.

  • PDF

A Study on the Implementation of Power Line Modem for Remote Control Using DSP (DSP를 이용한 원격 제어용 전력선 모뎀 구현에 관한 연구)

  • Kim Su Nam;Kang Dong Wook;Kim Ki Doo;Yoo Hyeon Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10C
    • /
    • pp.1433-1443
    • /
    • 2004
  • The power line modem proposed in this paper transmits the remote control signal using CSK(Code Shift Keying) and DS/SS method. The CSK technique provides the increased capacity of transmission and robustness towards noise. Besides, the DS/SS technique provides protection against narrow-band Gaussian interference and multi-path interference. The modem supports full-duplex communication using FDD(Frequency Division Duplex) and the modem structure for forward link is same with that for reverse link. To switch each sub-controlled unit smoothly, 4/$\pi$-DQPSK is adopted for noncoherent demodulation. The PN code for spreading spectrum seues to divide each group which consists of sub-controlled units and Walsh code is used for the M-ary CSK technique. Each block is designed and verified with TMS320C5402 DSP. We show the superiority of the proposed method by analyzing numerically the system performance for the factors of the DS/SS and CSK method ullder additive white Gaussian noise and PBI.