• 제목/요약/키워드: Duct system

검색결과 693건 처리시간 0.033초

액상분사식 LPG엔진 인젝터의 후적 및 아이싱 특성에 관한 연구 (A Study of Droplets and Icing Characteristics on Injector in a Liquid Phase LPG Injection Engine)

  • 김창업;최교남;강건용;박철웅
    • 한국분무공학회지
    • /
    • 제12권1호
    • /
    • pp.38-44
    • /
    • 2007
  • Since the Liquid Phase LPG injection (LPLI) system has Advantages in power generation and emission characteristics compared to the mixer-type fuel-supply system, a variety of studies regarding LPLi system has been conducted and its applications are made in automobile industry. However, the heat extraction due to the evaporation of liquid fuel, causes not only a post-accumulation of fuel but also an icing phenomenon which is a frost of moisture in the air around the nozzle tip. Since there exists a difficulty in the accurate control of air fuel ratio in both fuel supply systems, it can result in poor engine performance and a large amount of harmful emissions. This research examines the characteristics of icing phenomenon and develops anti-icing bushing to prevent an icing on the surface of the injection tip. It was found that n-butane, which has a relatively high boiling point ($-0.5^{\circ}C$), was a main species of post-accumulation. Also the results show that the post-accumulation problem was allevaited the utilization of a large inner to outer bore ratio and smooth surface roughness. In addition, an icing phenomenon and its formation process were found to be mainly affected by the humidity and the temperature of inlet air in an inlet duct. Also, it was observed that an icing phenomenon is lessened using aluminum bushing whose end coincides with the end of fuel injection tip in length.

  • PDF

Estimation of Friction Coefficient Using Smart Strand

  • Jeon, Se-Jin;Park, Sung Yong;Kim, Sang-Hyun;Kim, Sung Tae;Park, YoungHwan
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.369-379
    • /
    • 2015
  • Friction in a post-tensioning system has a significant effect on the distribution of the prestressing force of tendons in prestressed concrete structures. However, attempts to derive friction coefficients using conventional electrical resistance strain gauges do not usually lead to reliable results, mainly due to the damage of sensors and lead wires during the insertion of strands into the sheath and during tensioning. In order to overcome these drawbacks of the existing measurement system, the Smart Strand was developed in this study to accurately measure the strain and prestressing force along the strand. In the Smart Strand, the core wire of a 7-wire strand is replaced with carbon fiber reinforced polymer in which the fiber Bragg grating sensors are embedded. As one of the applications of the Smart Strand, friction coefficients were evaluated using a full-scale test of a 20 m long beam. The test variables were the curvature, diameter, and filling ratio of the sheath. The analysis results showed the average wobble and curvature friction coefficients of 0.0038/m and 0.21/radian, respectively, which correspond to the middle of the range specified in ACI 318-08 in the U.S. and Structural Concrete Design Code in Korea. Also, the accuracy of the coefficients was improved by reducing the effective range specified in these codes by 27-34 %. This study shows the wide range of applicability of the developed Smart Strand system.

증발 냉각방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발 (Development of Temperature Control Technology of Root Zone using Evaporative Cooling Methods in the Strawberry Hydroponics)

  • 김기동;하유신;이기명;박대흠;권순구;박종민;정성원
    • 생물환경조절학회지
    • /
    • 제19권4호
    • /
    • pp.183-188
    • /
    • 2010
  • 본 연구는 딸기의 수경재배에서 증발냉각방식을 이용하여 배지의 지하부 온도를 관리할 수 있는 냉각시스템을 개발하고 고온기 온실내 기온에 따른 배지내 온도분포 특성을 분석하고자 다공질 필름 덕트법, 배지 상면 기습부직포 멀칭법, 투수부직포 재배조 표면 증발법의 3가지 냉각시스템에 대하여 배지냉각특성을 시험하였다. 그 결과 투수부직포 재배조 표면 증발법의 경우 온실내 기온 $35^{\circ}C$인 배지표면의 온도와 상대습도 50%일 때 재배조 표변의 부직포의 온도는 $27^{\circ}C$로 니타났으며, 뿌리가 많이 분포되어 있는 배지내 온도는 $28{\sim}30^{\circ}C$ 정도로 나타나 외기온에 비하여 $5{\sim}7^{\circ}C$ 정도로 기장 크게 강하되었다. 따라서, 투수부직포 재배조 표면 증발법이 가장 효율적인 배지냉각 방법이라고 판단된다.

히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구 (A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes.)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF

다차원 해석법을 이용한 자동차 공조시스템의 기여도분석 (Coherent Analysis of vehicle HVAC Using the MDSA Method)

  • 오재응;황동건;아미누딘;이정윤;김성수
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.143-150
    • /
    • 2005
  • To verify applicability of multi-dimensional spectral analysis (MDSA) fur noise source identification two different approaches which are frequency response and coherent function have been investigated. The coherence function approach appears able to separate the correlated system when the noise sources were coherent. In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using MDSA method. Firstly, to identify the applicability of MDSA method, 4-inputs of vehicle HVAC system were the signals measured by accelerometers attached on the selected noise sources which were composed of blower, evaporator, heater and duct. While 1-output which was driver's position sound was the SPL signals measured by a remote microphone, when the blower motor was operating. We identify efficiency of systems modeled with four Inputs/single output through ordinary coherence function (OCF) and partial coherence function (PCF). As a result of experiment, the blower accounted for $62-88\%$ of the overall level of sound energy density. Also, according to the analysis of acoustic signal and vibration signals measurement, an investigation of the noise source identification in the vehicle HVAC is presented. With the sound intensity method, the major sources of the vehicle HVAC radiation are verified. Also the method of improving the noise reduction is proposed by attaching damping patch access to blower motor and noise reduction is verified.

열음향 냉동기의 설계 및 개발 : I. 내부공간의 음향해석 및 에너지 변환 예측 (Design and Development of Thermoacoustic Rdfrierator : I. Acoustic Analysis of Resonator and Prediction of Energy Conversion)

  • 박철민;이정권
    • 한국음향학회지
    • /
    • 제15권5호
    • /
    • pp.44-52
    • /
    • 1996
  • 열음향 냉동기의 설계시 요구되는 냉동기의 내부음장 특성을 예측하기 위해, 냉동기를 이루는 공명기 구조 및 선형화된 스피커의 모델에 대행 전달행렬기법을 이용하여 해석을 수행하였다. 여러 가지 기본 음향요소들의 전달행렬을 이용하여 공명기를 음향학적 요소들로 분해하고, 스피커의 선형화된 동특성 방정식과 함께 해석함으로써 음향요소들이 직렬로 배열되어 있는 공명기에 대한 음향특성을 얻어 내었다. 또한, 열음향 냉동기의 개발에 있어서 중요한 목표중 하나인 모세관 스택에서의 온도차이를 에너지 방정식을 이용하여 수치적으로 예측하였다. 한 개의 모세관 기공내에서의 음향일의 흐름, 열음향 흐름, 단위 길이당 에너지 손실 등을 단면변화함수를 이용해 표시한 후, 전체 스택에서의 에너지 흐름과 열평형을 고려하였다. 전체 스택에서의 에너지 흐름에 관한 식에 대하여, 내부음장 예측에 의해 구한 물리량을 이용하여, 수치적인 반복계산을 수행함으로써 온도비 및 성적계수를 예측할 수 있었다. 실제 설계된 공명기의 음향 특성의 해석결과가 실험과 잘 일치함을 관찰한 후, Hofler의 열음향냉동기에 대한 열음향 해석을 수행하여 실험결과와 잘 부합됨을 확인할 수 있었다.

  • PDF

대학 시설물관리시스템 구축에 관한 기초적 연구 (A Preliminary Study on the Construction or the AM/FM System for a Univesity)

  • 안기원;이효성;신석효
    • 한국측량학회지
    • /
    • 제15권2호
    • /
    • pp.277-286
    • /
    • 1997
  • 본 연구는 경남 진주시 소재 경상대학교를 표본으로 하는 대학 시설물관리시스템의 기초적 구축에 목적이 있다. 대학 시설물관리시스템의 구축을 위하여 사용된 도형자료의 입력에는 1/1200, 1/3000 그리고 1/5000인 경상대학교 현황도, 1/1200인 공동구 계획도, 1/1200의 시설도면을 입력하였고, 속성자료로서는 각 관의 설치년도, 재질, 관경, 길이, 깊이, 경사 등을 입력하였다. 데이터베이스 구축은 자료의 검색, 분석, 처리가 가능한 관계형 구조를 이용하였다. 또한 대학 시설물관리시스템에 있어서는 계획 및 수행에 필요한 신속 정확한 정보의 제공으로 효율적인 도면관리 업무의 능률화 및 고도화를 기하였다. 또한 독립된 시스템을 만들기 위해서 보편성이 적은 상업용 S/W를 쓰지 않고 독립된 시스템으로 운영하고자 하였으며, 사용자가 편리하도록 대학 시설물관리시스템 구축을 위한 응용프로그램을 Visual Basic S/W로 객체지향 프로그래밍기법을 이용하여 작성하였다.

  • PDF

IGCC 합성가스 급속 냉각시스템의 운전 압력에 따른 열유동 및 입자 거동 특성 연구 (Effect of Operating Pressure on the Heat Transfer and Particle Flow Characteristics in the Syngas Quench System of an IGCC Process)

  • 박상빈;양주향;오준호;예인수;류창국;박성구
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.97-104
    • /
    • 2014
  • In a coal gasifier for IGCC, hot syngas leaving the gasifier at about 1550oC is rapidly quenched by cold syngas recycled from the gas cleaning process. This study investigated the flow and heat transfer characteristics in the gas quench system of a commercial IGCC process plant under different operating pressures. As the operating pressure increased from 30 bar to 50 bar, the reduced gas velocity shortened the hot syngas core. The hot fly slag particles were retained within the core more effectively, and the heat transfer became more intensive around the hot gas core under higher pressures. Despite the high particle concentrations, the wall erosion by particle impaction was estimated not significant. However, large particles became more stagnant in the transfer duct due to the reduced gas velocity and drag force under higher pressures.

TBM 도로터널의 환기방식에 따른 최적단면 선정에 관한 연구 (A study on the selection of optimal cross section according to the ventilation system in TBM road tunnels)

  • 이호근;강현욱;김현수;김홍문
    • 한국터널지하공간학회 논문집
    • /
    • 제15권2호
    • /
    • pp.135-148
    • /
    • 2013
  • 최근 도로터널은 장대화되고 있으며 도심지 등의 장대 대심도 도로터널의 계획이 추진되고 있다. 이러한 장대, 대심도 터널 굴착공법은 NATM과 TBM 공법 등이 있으며 유럽에서는 약 80%, 기타 선진국에서도 약 30%의 교통터널에서 Shield TBM 공법을 적용하고 있다. 하지만 국내에서는 대부분의 장비가 외국에서 고가에 수입되고 있어 국내의 TBM 터널 보급률이 상당히 낮아 NATM 굴착방식이 보편적으로 적용되고 있는 실정이다. TBM 터널의 보급을 늘리기 위해서는 TBM 장비의 국내 수급을 통한 경제성의 확보가 필요하며 이를 위해 표준화된 TBM 구경의 선정이 시급한 실정이다. 따라서 본 연구에서는 도로터널의 표준화된 TBM 최적단면 선정을 위해 교통량에 따라 차로수의 규모 및 내부형상(단층 혹은 복층), 환기방식에 따른 TBM 굴착 내공단면을 활용 방안 등을 검토하여 최적 단면의 산출방안을 제시하고자 하였다.

습식 배연탈황 시스템의 효율 향상을 위한 전산해석 (Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas)

  • 황우현;이경옥
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권2호
    • /
    • pp.161-171
    • /
    • 2014
  • 본 논문에서는 CFDRC 사의 상용 CFD 소프트웨어인 CFD-ACE+로 전산유체역학 기법을 적용하여 수치 해석을 수행하여 배연탈황 설비에서 Induced Draft Fan(I.D.Fan) 출구부터 Booster Up Fan(B.U.Fan) 입구까지 난류 유동장과 연소 유동 문제를 모사하여 배기가스 계통 설비의 유동 특성을 해석하였다. 배기가스가 I.D.Fan 출구 ~ B.U.Fan 입구 구간을 적정속도로 균일하게 유동하여 B.U.Fan로 균일하게 유입되도록 하며 압력손실이 적게 발생하도록 설계기준 보일러 부하와 최대연속 정격유량의 보일러 부하에서 이 구간의 안내깃을 검토하였다. 검토한 결과에 대해 CFD 해석을 수행하여 I.D.Fan 출구에서 안내깃을 제거하고 B.U.Fan 입구 전에 안내깃을 보강할 수 있도록 설계를 변경하였다. 배기가스 계통에 변경된 설계를 적용하여 수치모사한 결과에서 배연탈황 설비 내부의 배기가스 압력손실이 줄어들고 유속과 유선이 균일하게 유동할 수 있어 배연탈황 시스템의 효율이 향상한 것을 확인하였다.