• 제목/요약/키워드: Duct Flow

검색결과 795건 처리시간 0.029초

사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석 (CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector)

  • 구성모;오원철;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

S자형 환형덕트가 원심압축기 성능에 미치는 영향에 관한 연구 (A Study on the Influence of S Shaped Annular Duct on the Centrifugal Compressor Performance)

  • 정주현;전승배;김승우
    • 한국추진공학회지
    • /
    • 제2권2호
    • /
    • pp.64-73
    • /
    • 1998
  • 항공기용 엔진에는 압축기단들 사이에 스트럿을 포함하는 S자형 환형덕트가 존재하기도 한다. 이러한 엔진에서 S자형 덕트를 통과하는 유동은 볼록면과 오목면을 따라 가면서 가속과 감속이 이루어지고, 벽면에서의 경계층 성장으로 인해 유로폐쇄량이 증가한다. 이처럼 S자형 덕트의 영향으로 후방에 존재하는 압축기는 불균일한 축방향 속도분포에 따른 영향을 받게 된다. 따라서, 후방 압축기는 전방에 위치한 S자형 덕트의 영향을 충분히 고려하여 설계하여야 한다. S자형 덕트가 미치는 영향을 고려하여 설계된 원심압축기의 성능을 검증하고, S자형 덕트가 원심압축기 성능에 미치는 영향을 파악해보기 위해 압축기 입구에 S자형 환형덕트를 장착한 경우와 원통형 덕트를 장착한 경우에 대해 각각 성능시험을 수행하였다. 시험결과를 통해 입구에 S자형 덕트가 있는 경우에는 없는 경우보다 압축비 및 효율 등 압축기 성능이 저하되고, 쵸킹유량이 감소함을 알 수 있었다. 이러한 성능저하의 원인을 분석하기 위해 S자형 덕트를 포함하는 임펠러의 유동해석을 수행하였으며, 그 결과 성능저하의 원인은, S자형 덕트와 임펠러의 상호작용으로 설계시 예측했던 것보다 인듀서팁에서 상대마하수가 증가하였고, 영각이 감소하였기 때문임을 확인할 수 있었다.

  • PDF

S-Duct 입구 형상에 따른 유동 특성에 관한 연구 (A Study on Flow Characteristics of the Inlet Shape for the S-Duct)

  • 이지형;최현민;류민형;조진수
    • 한국항공우주학회지
    • /
    • 제43권2호
    • /
    • pp.109-117
    • /
    • 2015
  • 덕트는 항공기의 내부엔진에 외부 공기를 흡입하기 위한 장치이다. 엔진 입구면의 레이더 반사량을 줄여 피탐지성을 감소시키기 위하여 S형태의 덕트를 가지게 되었다. S-Duct는 중심선의 곡률, 입구형상 등의 형상변수에 따라 엔진의 성능에 영향을 미친다. 본 연구에서는 RAE M 2129 S-Duct의 입구형상에 대하여 가로세로비의 변경에 따른 덕트 내부 유동에 대한 유동 특성을 알아보기 위해 전산해석을 수행하였다. S-Duct의 성능 평가 기준으로는 유동 왜곡계수를 사용하였다. 공력해석을 위해 상용해석 소프트웨어를 사용하였으며, 벽면에서의 역압력 구배의 영향으로 발생하는 유동박리와 2차 유동을 예측하기 위하여 $k-{\omega}SST$ 난류모델을 사용하였다. S-Duct의 Port side와 Starboard side 각각의 압력분포 값에 대하여 ARA의 실험값과 비교하여 본 연구에서 사용된 전산해석 기법의 타당성을 검증하였다. 해석 결과 모든 형상에 대하여 유동박리와 2차 유동이 발생하는 것을 확인하였다. 반원형 형태의 입구형상을 가지는 S-Duct가 뛰어난 성능을 보임을 확인하였다.

S-duct 내부유동의 출구경계조건 및 난류모텔의 영향검토 (Effects of Outflow Boundary Conditons and Turbulent Models on an S-duct Flow)

  • 홍승규;이광섭
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.120-126
    • /
    • 2000
  • An S-duct flow is subjected to an entrance flow of Mach 0.6. The duct turns $30^{\circ}$ and reverses its turn by $30^{\circ}$ followed by a straight section. Such an internal flow induces a secondary flow due to curvature effect. Goal of this paper is to show the sensitivity of outflow boundary conditions on the quality of numerical solutions as well as to show curvature effect on the flow field. The often-used Baldwin-Lomax turbulence model is shown to be less functional on the concave region when the secondary flow has its strong Influence.

  • PDF

곡관덕트의 입구영역에서 천이비정상유동의 속도분포와 임계딘수에 관한연구 (A Study on Velocity Profiles and Critical Dean Number of Developing Transitional Unsteady Flows in a Curved Duct)

  • 이행남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.862-870
    • /
    • 1998
  • In this paper an experimental investigation of characteristics of developing transitional unsteady flows in a square-sectional 180。 curved duct are presented. The experimental study using air is carried out to measure axial velocity profiles secondary flow velocity profiles and entrance length by using Laser Do ppler Velocimeter(LDV) system. The flow development is found to depend upon Dean number dimensionless angular frequency velocity amplitude ration and cur-vature ratio. Of special interest is the secondary flow generated by centrifugal effects in the plane of the cross-section of the duct. The secondary flows are strong and complicate at entrance region. The entrance length of transitional pulsating flow is obtained to 120。 of bended angle of duct in this experimental conditions.

  • PDF

바울형 미분기 베인휠에서의 유속 불균일 개선에 관한 연구 (Improvement of Maldistributed Air Velocity in the Vane Wheel of a Bowl Type Pulverizer)

  • 박덕배;허진혁;문승재
    • 플랜트 저널
    • /
    • 제6권2호
    • /
    • pp.62-69
    • /
    • 2010
  • The stability of coal pulverizer in the 800 MW coal-fired plants is vital to maintain their performance. Thus, this study analyzed the uneven abrasion of the deflector and coal spillage due to the air velocity maldistribution in the vane wheel of a bowl-type pulverizer as it is a possible cause for problems of facility using pulverized coal. In addition, air flow in the underbowl of a bowl-type pulverizer was studied to check air velocity maldistribution in the vane wheel using numerical method. In an attempt to correct the maldistribution of air velocity, air flow of the modified duct vane was studied as enlarging the length of the duct vanes installed at the air inlet duct of the pulverizer and increasing the angle of inclination. It was found that modified duct vane make the velocity distribution at the vane wheel uniform. formed by the duct vanes installed at the air inlet duct of the pulverizer and swirling flow is the major factor in making the velocity distribution of vane wheel exit uniform. This can prevent the uneven abrasion of the deflector, which is one of the components inside the pulverizer and coal spillage.

  • PDF

등압법과 T-method를 이용한 공조시스템 배관 설계에 관한 연구 (A Study on the Duct Design of HVAC System Using the Equal Friction Method and the T-method)

  • 박준석;최길환;조대승
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.435-443
    • /
    • 2009
  • Optimal duct design of a HVAC system requires analysis technology to accurately evaluate its pressure losses, flow rate and velocity for making a compromised design among fan capacity and duct size affecting initial manufacturing and operation costs, and noise induced by the HVAC system. In this paper, we carry out initial duct design using the equal friction method. Using the result, the T-method is applied for accurate analysis of flow rate. Then, the duct size is modified using the difference between the required and the calculated flow rate, which can guarantee required flow rate, reduce the pressure unbalance among duct paths and lead to select optimal fan performance. To verify the validity and effectiveness of the proposed design method, an example for HVAC system design including noise analysis is demonstrated.

비정렬 셀 중심 방법에 의한 정사각형 단면을 갖는 $90^{\circ}$ 곡관 층류유동의 수치해석 (NUMERICAL SIMULATION OF INCOMPRESSIBLE LAMINAR ENTRY FLOWS IN A SQUARE DUCT OF $90^{\circ}$ BEND BY UNSTRUCTURED CELL-CENTERED METHOD)

  • 명현국;김종은
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.81-85
    • /
    • 2005
  • Three-dimensional steady incompressible laminar entry flows in a square duct of $90^{\circ}$ bend are numerically simulated by a new solution code(PowerCFD) using unstructured cell-centered method. Solutions are obtained with three unstructured grid types of hexahedron, prism and hybrid at a Reynolds number, based on the hydraulic diameter and bulk velocity, of 790. Interesting features of the flow are presented in detail. Detailed comparisons between the computed solutions and the available experimental data are given mainly for the velocity distributions at cross-sections in a $90^{\circ}$ bend of a square duct with fully-developed entry flows. It is found that the code is capable of producing the nature of laminar flow in curved square duct with no grid type dependency.

  • PDF

사각덕트내의 유체유동에 관한 수치계산과 실험의 비교 (The comparison between Numerical Computation and Experiment on Fluid Elow in Rectangular Duct)

  • 윤영환;배택희;박원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.71-74
    • /
    • 2002
  • Fluid flow in a rectangular duct system are measured by W laser doppler velocity meter, and also computed by commercial software of STAR-CD for comparison between then First, for a rectangular duct with 90 degree metered elbow, the fluid flow with Reynolds numbs's of 1,508 is predicted by assumption of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300-3,000, the computation by turbulent model is close to the experimental data. Moeover, the computation by turbulent model for Reynolds number of 11,751 also predicts the experimental data satisfactorily. Second, for a rectangular duct with two branch ducts, the ratios between flow rates in the two branches are invariant to Reynolds number according to both of numerical and experimental results.

  • PDF

덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구 (A Study on the Optimal Orifice Location for Air flow Measurement in an Air Duct Leakage Tester)

  • 이승철
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.186-191
    • /
    • 2006
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I where upstream duct length is 6 D, and that in the downstream is 4 D and different downstream distance to the fan in the rest, so as to determine the optimal location of the orifice and reduce the duct length of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of $\pm7.5\%$ based on the real flow rate. Also, the best one of five. cases was achieved with the orifice located midway of the orifice duct four times its diameter long.