• Title/Summary/Keyword: Duck Bone

Search Result 60, Processing Time 0.025 seconds

The Analysis of Stress and Variation of Cement Thickness as the Variation of Design Variables for Custom-Made Hip Implant (Cement Type 맞춤형 인공고관절의 설계 변수 변화에 따른 Cement 두께 변화와 이에 대한 응력 분석)

  • Park, Heung-Seok;Chun, Heoung-Jae;Youn, In-Chan;Lee, Moon-Kyu;Seo, Duck-Chan;Choi, Kui-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.402-408
    • /
    • 2006
  • The choice of suitable hip implant is one of important factors in the total hip arthroplasty (THA). In clinical view point, an improper adaptation of hip implant might induce abnormal stress distribution to the bone, which can shorten the lifespan of replaced hip implant. Currently, interest in the custom-designed hip implants has increased as studies reveal the significance of geometric shape of patient's femur in modeling and designing the implants. In this study, we have developed custom-designed hip implant models with various sizes, and analyzed the stress distribution in the bone and bone cement using the Finite Element Method. It was found that minimizing the gap between implant stem and femoral cavity is crucial to minimize the stress concentration in the bone.

Component characteristics of fish bone as a food source (식품소재로서 어류뼈의 성분 특성)

  • Choi, Jong-Duck;Koo, Jae-Geun;Kim, Jin-Soo
    • Applied Biological Chemistry
    • /
    • v.41 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • As a part of basic investigation for utilizing by-products derived from seafood processing as a food source, a chemical characteristics of fish bones (cod bone, Alaska pollack bone, yellowfin sole bone, hoki bone, conger eel bone and mackerel bone) were investigated. The crude protein (40.7% on the dry basis) and collagen contents (5.86%, on the dry basis), imino acid composition (189 residues/1,000 residues) of hoki bone were higher than those of the other fish bones, but were lower than those of the animal bone. The crude lipid contents and EPA and DHA compositions of yellowfin sole, conger eel and mackerel bones were $22.8{\sim}43.9%$ on the dry basis and $15.6{\sim}23.8%$, respectively and were lower than those of squid viscera. The major ash components of the fish bones were found to be calcium and phosphorus and the contents in 100 g crude ash were $37.1{\sim}38.6%$ and $18.0{\sim}18.5%$ respectively. The calcium and phosphorus contents in 100 g crude ash of cod and Alaska pollack bones were more than those of the animal bones, as well as the others. It may be concluded, front these results, hoki bone can be effectively utilized as a processing materal of collagen or gelatin and cod and Alaska pollack bones as a calcium source.

  • PDF

A Case of Canine Lymphosarcoma (개의 임파육종의 1예)

  • Kim Duck-Hwan;Kim Kyo-Joon;Cho Sung-Whan;Jun Moo-Hyung;Kwon Oh-Deog;Bae Kyu-Yul;Lee Yong-Sun
    • Journal of Veterinary Clinics
    • /
    • v.3 no.2
    • /
    • pp.309-316
    • /
    • 1986
  • One six-year-old male Cocker spaniel with chief complaints of mandibular swelling and anorexia was referred. This dog was diagnosed into lymphosarcoma by the results of the examination with peripheral blood and fluid of the lymph nodes and bone marrow aspirated. This patient was multicentric form clinically and was cytomorphologically identified into lymphoblastic form of lymphosarcoma.

  • PDF

AUGMENTATION OF MAXILLARY ANTERIOR AREA USING DISTRACTION OSTEOGENESIS : CASE REPORT (골신장술을 이용한 상악 전치부 수복의 치험보고)

  • Kim, Hyun-Kyung;Lee, Hyun-Jin;Yeo, Duck-Sung;Lim, So-Yeon;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.242-246
    • /
    • 2006
  • Objective : This is to report the criteria of success of intraoral distraction osteogenesis for alveolar augmentation in the severely atrophied alveolar defects through clinical result of 2 cases. Subjects and Methods : Anterior segmental osteotomy was performed and alveolar distractors (Martin and Leibinger, Germany) were applied each in 2 patients with severely defected anterior maxillary area. The osteomized alveolar segments were distracted by 1mm a day after latency period. After the consolidation period implants were installed with removal of distractor. The implants were evaluated clinically and radiographically. Results : In Case I, the distracted bone was directed to the palatal side, and another augmentation treatment - block bone graft, guided bone regeneration - was needed. In Case II, the successful alveolar bone augmentation was achieved. Dental implant was placed on distracted alveolar bone, and showed good osseointegration and good function without any complication. Conclusion : Distraction osteogenesis can be a good choice for alveolar ridge augmentation of severely atrophied ridges. However, the anterior esthetic prosthetics relies on the control of the vector, the kind of distractor, the healing capacity of patient and the etiology of atrophy. Therefore another study of each category would be needed.

Physical Activity in Adolescence Has a Positive Effect on Bone Mineral Density in Young Men

  • Kim, Jinhyun;Jung, Moonki;Hong, Yeon-Pyo;Park, Jung-Duck;Choi, Byung-Sun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.2
    • /
    • pp.89-95
    • /
    • 2013
  • Objectives: Little is yet known about the determinants of bone mineral density (BMD) in young adults. Thus, in this study, we aimed to determine the factors that have an impact on BMD in young men. Methods: Questionnaires were sent out to 111 male medical students. Information on age, socio-economic status, medical history, lifestyle, physical activity during adolescence, school club participation, current physical activity, and dietary intake were collected by the survey. Height, weight, percent body fat and muscle mass were estimated by bioelectrical impedance, and BMD was obtained using calcaneal quantitative ultrasound. Using the Poisson regression model, prevalence ratios (PRs) were used to estimate the degree of association between risk factors and osteopenia. Results: The height and current physical activity showed a correlation to the Osteoporosis Index. Among the categorized variables, past physical activity during adolescence (p= 0.002) showed a positive effect on the bone mineral content. In the multivariate model, past physical activity (${\geq}1$ time/wk) had a protective effect on osteopenia (PR, 0.37; 95% confidence interval [CI], 0.18 to 0.75) and present physical activity (1000 metabolic equivalent of task-min/wk) decreased the risk of osteopenia (PR, 0.64; 95% CI, 0.44 to 0.91). Conclusions: Past physical activity during adolescence is as important as physical activity in the present for BMD in young men.

A study on growth and development of children by Ultrasound transonic velocity of inferior radiocarpal joint (완관절 초음파통과속도를 이용한 골연령 측정값과 X-ray영상을 이용한 골연령 측정값의 비교)

  • Koh, Duck-Jae;You, Han-Jung;Lee, Jin-Yong;Kim, Deog-Gon;Yoon, Kyung-Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.165-174
    • /
    • 2005
  • Objectives : The purpose of this study was to suggest a new method for measurement of children's growth development Ultrasound transonic velocity of inferior radiocarpal joint has some advantages that it is harmless to human body and apply a new analysis algorithm, it can be used for the diagnosis of bone age. Methods: This clinical study have been carried out with the 117 case(male 68, female 49) of the children aged 5 to 16 years old who visited in Department of Pediatrics, ${\bigcirc}{\bigcirc}$ university Oriental Hospital. Bone maturity is measured by Ultrasound transonic velocity and X-ray image of growth plate in inferior radiocarpal joint. This study were designed to investigate the relationship of the bone age by Ultrasound transonic velocity and X-ray image. Result & Conclusion : The maturity of growth plate of inferior radiocarpal joint was correlated with age, height, weight, BMI in this study(P<0.001). The Ultrasound transonic velocity of inferior radiocarpal joint are sufficient diagnostic worth as an index to predict bone maturity.

  • PDF

Comparative Biomechanical Study of Self-tapping and Non Self-tapping Tapered Dental Implants in Artificially Simulated Quality 2 Bone

  • Baek, Yeon-Wha;Kim, Duck-Rae;Park, Ju-Hee;Lim, Young-Jun
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • Purpose: Modifications of implant design have been related to improving initial stability. The purpose of this study was to investigate their respective effect on initial stability between two tapered implant systems (self-tapping vs. non-self-tapping) in medium density bone using three different analytic methods. Materials and Methods: Self-tapping implant (GS III$^{(R)}$; Osstem Implant Co., Busan, Korea) and non-self-tapping implant (Replace Select$^{(R)}$; Nobel Biocare, G$\H{o}$teborg, Sweden) were investigated. In Solid rigid polyurethane blocks of artificially simulated Quality 2 bone, each of the 5 implants was inserted according to the manufacturer's instructions for medium-bone drilling protocol. Evaluation of initial stability was carried out by recording the maximum insertion torque (IT) and performing the resonance frequency analysis (RFA), and the pull-out test. Results: The IT and RFA values of self-tapping implant were significantly higher than those of non self-tapping implant (P=.009 and P=.047, respectively). In the pull-out values, no significant differences were found in implants between two groups (P=.117). Within each implant system, no statistically significant correlation was found among three different outcome variables. Conclusions: These findings suggest that design characteristics of implant geometry significantly influence the initial stability in medium bone density.

A CLINICOSTATICAL STUDY OF JAW CYST BETWEEN 2001${\sim}$2005 (최근 5년간 구강악안면 낭종 환자에 대한 통계학적 검토)

  • Lim, So-Yeon;Yeo, Duck-Sung;Lee, Hyun-Jin;Kim, Hyun-Kyung;An, Kyung-Mi;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.588-593
    • /
    • 2006
  • Cyst is pathologic disease develops in hard tissue as well as soft tissue, which is lined by epithelium filled with liquid, semi-liquid, or air. Origins and symptoms of the cyst are various according to region, and symptoms are malocclusion, diversion of root, tooth mobility, periapical swelling, discoloration and lesion expansion, because the odontogenic cysts begin in the numerous rests of odontogenic epithelium. But almost cysts produce no symptoms unless secondary infection occurs. Treatment of small cysts may include extraction, endodontic therapy, and apical surgery. Treatment of a large cysts usually involves surgical removal (enucleation), Marsupialization(a method of decompression) or combination of two before mentioned. Bone graft is done for helping of bone defect healing at the same time of enucleation This clinical research from January 2000 to December 2005, analyzed by the age, sex, classification, size, region, treatment method, whether or not of bone graft of cyst in the jaw in Daegu Catholic University Hospital.

MINI-IMPLANTS TO RESTORE MISSING TEETH IN SEVERE RIDGE DEFICIENCY AND SMALL INTERDENTAL SPACE (치조정 골 소실이 심한 경우와 치간 사이 공간이 부족한 경우에서의 미니 임프란트 식립)

  • Seo, Mi-Hyun;Yoo, Chung-Kyu;Lee, Eun-Kyung;Jung, Da-Unn;Suh, Je-Duck;Chung, Il-Hyuk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.67-70
    • /
    • 2009
  • Purpose: This study presents the use of mini implants for fixed restoration and implant supported overdenture to enable the practitioner to overcome the anatomic obstacles of ridge width and narrow interdental space. Patients and methods: This study consisted of 9 patients who required single implants for one or two teeth replacement and 1 patient who required implant supported overdenture after mandiblectomy, iliac bone graft due to ghost cell tumor. The ages ranged from 29 to 70 years (mean 51). All patients were in good health. Clinical and radiographs were taken pretreatment, postoperatively, during rehabilitation, and at follow ups. Results: Total implant survival rate was 94.7%. One implant was removed due to its mobility as a result of bad bone quality (Type IV) and patient's carelessness (Heavy smoker). All patients except one reported complete satisfaction regarding to function, aesthetics, and phonetics. Radiographic follow up every 3months postoperatively showed success in achieving function and maintaining marginal bone level. Conclusion: Clinician can overcome both severe ridge deficiency and small interdental space with mini implant.

In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality (연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구)

  • Kim, Duck-Rae;Kim, Myung-Joo;Kwon, Ho-Beom;Lee, Seok-Hyung;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.391-401
    • /
    • 2009
  • The successful outcome of dental implants is mainly the result of intial implant stability following placement. The aim of this study was to investigate the effect of a self-tapping blades and implant design on initial stability of two tapered implant systems in poor bone quality. The two different implant systems included one with self-tapping blades and one without self-tapping blades. D4 bone model using Solid Rigid Polyurethane Form was used to simulate poor bone densities. The insertion torque during implant placement was recorded. Resonance frequency Analysis (RFA), measured as the implant stability quotient (ISQ), was assessed immediately after insertion. Finally, the implant-bone specimen was transferred to an Universal Testing Machine to measure the axial pull-out force. Insertion torque values and maximum pull-out torque value of the non self-tapping implants were significantly higher than those in the self-tapping group (P = 0.008). No statistically differences were noted between the two implant designs in RFA. Within the each implant system, no correlation among insertion torque, maximum pull-out torque and RFA value could be determined. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical initial stability. In conclusion, implants without self-tapping blades have higher initial stability than implants with self-tapping blades in poor bone quality.