• Title/Summary/Keyword: Dual-frequency

Search Result 1,208, Processing Time 0.024 seconds

Double Mediating Effect of Learning Motivation and Grit between Emotional Intelligence and Learning Engagement in Chinese High School Students (중국 고등학생의 정서지능과 학습몰입의 관계에서 학습동기와 그릿의 이중매개효과)

  • Luo Zhiwen;Gao Runze;Chang Seek Lee
    • Industry Promotion Research
    • /
    • v.9 no.1
    • /
    • pp.213-221
    • /
    • 2024
  • This study aims to determine whether learning motivation and grit mediate in the relationship between emotional intelligence and learning engagement among Chinese high school students. Data were collected through a survey targeting 304 high school students purposively sampled from a high school in China. The collected data was analyzed using SPSS PC+ Win ver. 25.0 and SPSS PROCESS macro ver. 4.2. The statistical methods applied were frequency analysis, reliability analysis, correlation analysis, and dual mediation effect analysis. The conclusion of the study is as follows. First, emotional intelligence, learning motivation, grit, and learning engagement all showed significant positive correlations. Second, high school students' learning motivation and grit double-mediated in the relationship between emotional intelligence and learning engagement. Based on these results, this study proposed a plan to improve high school students' academic engagement by utilizing not only emotional intelligence but also learning motivation and grit.

Prescriptive analysis of liquid gastric digestive solutions (액상형 건위소화제의 방제학적 분석)

  • Hong Seok Lee;Min Ju Kim;Ye Bin Shin;Soo Myeong Kim;Sung Jong Shin;Kyung Hwan Jegal
    • Herbal Formula Science
    • /
    • v.32 no.3
    • /
    • pp.277-296
    • /
    • 2024
  • Objective : Dyspepsia is one of the most common ailments among Koreans, leading to a continuously expanding market for liquid digestive solutions. These products are popular due to their convenience and low risk of side effects. However, there is a lack of research on the basic prescription composition of these ingredients and their precise indications according to Korean Medicine. Methods : Drugs were selected from the Korea Pharmaceutical Information Service website (http://www.health.kr), focusing on oral and liquid products classified under the Ministry of Food and Drug Safety's category of stomach and digestive aids (category 233). Frequency analysis was conducted to determine the occurrence and combinations of herbal ingredients within each product. Additionally, the four properties and five flavors of each product were calculated using their herbal ingredient composition ratios, and Pearson correlation coefficients were employed to verify the linear relationships between the composition ratios of the ingredients. Results : A comparative analysis of 33 liquid digestive medicines revealed that Zingiberis Rhizoma was the most frequently used herb. The most common dual-herb combination was Zingiberis Rhizoma and Citri Unshius Pericarpium, and the most prevalent tri-herb combination was Zingiberis Rhizoma, Citri Unshius Pericarpium, and Cinnamomi Cortex. Pearson correlation coefficient analysis showed a strong positive correlation between the composition ratios of Zingiberis Rhizoma and Cinnamomi Cortex. The analysis of four properties and five flavors indicated that products with warm and bitter flavors were the most common. Conclusions : The most frequently used herbal combination in liquid digestive solutions was Zingiberis Rhizoma, Citri Unshius Pericarpium, and Cinnamomi Cortex. This composition is suitable for treating dyspepsia caused by cold-dampness in the digestive system.

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF

An 8b 240 MS/s 1.36 ㎟ 104 mW 0.18 um CMOS ADC for High-Performance Display Applications (고성능 디스플레이 응용을 위한 8b 240 MS/s 1.36 ㎟ 104 mW 0.18 um CMOS ADC)

  • In Kyung-Hoon;Kim Se-Won;Cho Young-Jae;Moon Kyoung-Jun;Jee Yong;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • This work describes an 8b 240 MS/s CMOS ADC as one of embedded core cells for high-performance displays requiring low power and small size at high speed. The proposed ADC uses externally connected pins only for analog inputs, digital outputs, and supplies. The ADC employs (1) a two-step pipelined architecture to optimize power and chip size at the target sampling frequency of 240 MHz, (2) advanced bootstrapping techniques to achieve high signal bandwidth in the input SHA, and (3) RC filter-based on-chip I/V references to improve noise performance with a power-off function added for portable applications. The prototype ADC is implemented in a 0.18 um CMOS and simultaneously integrated in a DVD system with dual-mode inputs. The measured DNL and INL are within 0.49 LSB and 0.69 LSB, respectively. The prototype ADC shows the SFDR of 53 dB for a 10 MHz input sinewave at 240 MS/s while maintaining the SNDR exceeding 38 dB and the SFDR exceeding 50 dB for input frequencies up to the Nyquist frequency at 240 MS/s. The ADC consumes, 104 mW at 240 MS/s and the active die area is 1.36 ㎟.

Design of a Spread Spectrum Clock Generator for DisplayPort (DisplayPort적용을 위한 대역 확산 클록 발생기 설계)

  • Lee, Hyun-Chul;Kim, Tae-Ho;Lee, Seung-Won;Kang, Jin-Ku
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.68-73
    • /
    • 2009
  • This paper describes design and implementation of a spread spectrum clock generator (SSCG) for the DisplayPort. The proposed architecture generates the spread spectrum clock using a sigma-delta fractional-N PLL. The SSCG uses a digital End order MASH 1-1 sigma-delta modulator and a 9bit Up/Dn counter. By using MASH 1-1 sigma-delta modulator, complexity of circuit and chip area can be reduced. The advantage of sigma-delta modulator is the better control over modulation frequency and spread ratio. The SSCG generates dual clock rates which are 270MHz and 162MHz with 0.25% down-spreading and triangular waveform frequency modulation of 33kHz. The peak power reduction is 11.1dBm at 270MHz. The circuit has been designed and fabricated using in 0.18$\mu$m CMOS technology. The chip occupies 0.620mm$\times$0.780mm. The measurement results show that the fabricated chip satisfies the DispalyPort standard.

Design of High-Performance Motion Estimation Circuit for H.264/AVC Video CODEC (H.264/AVC 동영상 코덱용 고성능 움직임 추정 회로 설계)

  • Lee, Seon-Young;Cho, Kyeong-Soon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.53-60
    • /
    • 2009
  • Motion estimation for H.264/AVC video CODEC is very complex and requires a huge amount of computational efforts because it uses multiple reference frames and variable block sizes. We propose the architecture of high-performance integer-pixel motion estimation circuit based on fast algorithms for multiple reference frame selection, block matching, block mode decision and motion vector estimation. We also propose the architecture of high-performance interpolation circuit for sub-pixel motion estimation. We described the RTL circuit in Verilog HDL and synthesized the gate-level circuit using 130nm standard cell library. The integer-pixel motion estimation circuit consists of 77,600 logic gates and four $32\times8\times32$-bit dual-port SRAM's. It has tile maximum operating frequency of 161MHz and can process up to 51 D1 (720$\times$480) color in go frames per second. The fractional motion estimation circuit consists of 22,478 logic gates. It has the maximum operating frequency of 200MHz and can process up to 69 1080HD (1,920$\times$1,088) color image frames per second.

A Study on Design of Reference Stations and Integrity Monitors for Maritime DGPS Recapitalization (해양용 DGPS 구조개선을 위한 RSIM 설계에 관한 연구)

  • Park, Sang-Hyun;Seo, Ki-Yeol;Cho, Deuk-Jae;Suh, Sang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.691-697
    • /
    • 2009
  • Hardware dedicated off-the-shelf maritime differential GPS RSIM lacks the open architecture to meet all the minimum maritime user requirements and to include future GNSS improvements after recapitalization. This paper carries out a study to replace existing hardware dedicated differential GPS RSIM with software differential GPS RSIM in order to make up the weak point of hardware dedicated off-the-shelf maritime differential GPS RSIM. In this paper, the architecture of software RSIM is proposed for maritime DGPS recapitalization. And the feasibility analysis of the proposed software differential GPS RSIM is performed as the first phase to realize the proposed architecture. For the feasibility analysis, the prototype RF module and DSP module are implemented with properties as wide RF bandwidth, high sampling frequency, and high speed transmission interface. This paper shows that the proposed architecture has the possibility of real time operation of software RSIM functionality onto the PC-based platform through the analysis of computation time. Finally, this paper verifies that the L1/L2 dual frequency software differential RSIM designed according to the proposed method satisfies the performance specifications set out in RTCM paper 221-2006-SC104-STD.

Molluscan Death Assemblages and Their Ecological Implications on a Tidal Flat, Inchon, Korea (인천연안 간석지산 연체동물 유해집단(遺骸集團)의 구조와 생태학적 의미)

  • Hong, Jae-Sang;Park, Heung-Sik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.2
    • /
    • pp.94-102
    • /
    • 1998
  • Temporal changes, density, calcimass, mode of occurrence, size-frequency histogram and survivorship curves were studied for the molluscan death assemblages on a macrotidal flat, Inchon, Korea. The living and death assemblages were compared on the basis of the taxonomic compositions and their numerical abundances. A total of 28 species (16 taxa in gastropods and 12 in bivalves) were identified. Most of the dead shells were the species inhabiting that intertidal mud flat. Species diversity was higher in gastropods than in bivalves. Seasonal variation of the calcimass was influenced by the mactrid bivalve, Mactra veneriformis. Shell-boring naticid gastropods preferred selecting the umbo areas of various valves. Size-frequency distribution and size-specific survivorship curves were analyzed for the dominant species. Survivorship curve of the tellinid bivalve, Morella rutila was convex-up in shape, which is congruent with the expected equilibrium condition but indicates higher mortality in winter. Whereas the survivorship curves of Mactra veneriformis and Reticunassa festiva were semi convex-up with dual modes, suggesting a disequilibrium due to the changes in recruitment and seasonal mortality. This study suggests that the dead shell assemblages may be useful in getting population information like live molluscan assemblages, if solved for several problems related to taphonomic processes.

  • PDF

Bone Mineral Density and Affecting Factors in College Women

  • Na, Hye-Bok;Jung, Shin-Yong
    • Journal of Community Nutrition
    • /
    • v.1 no.2
    • /
    • pp.98-107
    • /
    • 1999
  • The purpose of this study was to investigate Bone Mineral Density(BMD) and affecting factors on BMD of college women in Seoul. The subjects were 47 healthy college women aged 18-25 years. Antrophometric and body fat measurements were performed by Bioelectrical Impedance Fatness Analyzer(Tanita TVF 202). Blood pressure and pulse frequency were measured. Dietary intakes and general living habits were examined through questionnaires and nutrient intakes were analyzed by Computer Aided Nutritional Analysis(CAN) program for professional. Serum total cholesterol, TG(triglyceride), HDL-cholesterol, total protein, albumin, GOT, calcium were measured by Spotchem(SP-4410). Serum osteocalcin and alkaline phosphatase(ALP) were measured to monitor bone formation. BMD of lumbar spine(L2-L4), right hip(neck, ward's triangle, trochanter) and right forearm were measured by Dual Energy X-ray Absorptiometry(DEXA). Muscle strength was measured by examining leg flexion strength(right and left), leg extension power(right and left), handgrip power(right and left) and back strength. All data were statistically analyzed by the SAS PC package program. BMD of college women was normal(by WHO, 1994). Their muscle strength was bad(by national fitness guidebook, 1995). Only a mall number of them exercised (32.6% of subjects). There was no significant difference among BMD, muscle strength and % body fat(p<0.05). There were significant differences between BMD and total cholesterol as well as TG and VLDL-cholesterol(p<0.05). Total cholesterol was associated with decreasing BMD of the right forearm(p<0.05). TG and VLDL-cholesterol are associated with increasing BMD of right hip ward's triangle(p<0.05). There were significant differences among BMD, ALP and serum total protein. ALP was associated with decreasing BMD of the right forearm(p<0.05). There were significant differences between BMD and Ca as well as between Na and K intakes (p<0.05). Intakes of Na and K were associated with decreasing BMD of the right forearm (UD)(p<0.05). There were significant differences between in BMD and pulse frequently and serum albumin (p<0.05). Serum albumin is associated with increasing BMD of L3-L4(p<0.05), right hip neck(p<0.05). %Body fat, TG, VLDL-C, Ca intake, pulse frequency and serum albumin were associated with increasing BMD(p<0.05). Intakes of Na and K, ALP, total cholesterol, total cholesterol, total protein and height are associated with decreasing BMD(p<0.05). Overall results indicate that Ca intake but to be moderate in protein and Na intakes in order to increase BMD. Body exercise was recommended to increase BMD as well.

  • PDF

Characteristics of Bubble Flow Behavior in a Gas-liquid Countercurrent Bubble Column Bioreactor (기-액 향류 흐름 기포탑 생물 반응기에서 기포 흐름 거동 특성)

  • Son, Sung-Mo;Kang, Suk-Hwan;Lee, Chan-Gi;Jung, Sung-Hyun;Kang, Yong;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.272-277
    • /
    • 2005
  • Characteristics of bubbling behavior and bubble properties were investigated in a gas-liquid countercurrent bubble column of in diameter 0.152 m and 3.5 m in height, respectively. Effects of gas and liquid velocities and bubble distribution mode(even, wall-side, central or asymmetric distribution) on the bubble properties such as chord length, frequency, rising velocity and holdup in the reactor were measured and examined by means of dual resistivity probe method. The bubble size, frequency and holdup increased with increasing gas($U_G$) or liquid velocity($U_L$). The rising velocity of bubbles increased with increasing $U_G$, whereas decreased with increasing $U_L$. The uniformity of bubble size distribution and bubble holdup decreased when the distribution mode of bubbles at the gas distributor was changed from even to wall-side, central or asymmetric. The central distribution of bubbles was better than asymmetric mode but worse than wall-side distribution, in considering the bubble holdup and uniformity of distribution.