• 제목/요약/키워드: Dual-field-of-view

검색결과 44건 처리시간 0.026초

Infrared Dual-field-of-view Optical System Design with Electro-Optic/Laser Common-aperture Optics

  • Jeong, Dohwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Current Optics and Photonics
    • /
    • 제2권3호
    • /
    • pp.241-249
    • /
    • 2018
  • We report a midinfrared dual-field-of-view (FOV) optical system design for an airborne electro-optical targeting system. To achieve miniaturization and weight reduction of the system, it has a common aperture and fore-optics for three different spectral wavelength bands: an electro-optic (EO) band ($0.6{\sim}0.9{\mu}m$), a midinfrared (IR) band ($3.6{\sim}4.9{\mu}m$), and a designation laser wavelength ($1.064{\mu}m$). It is free to steer the line of sight by rotating the pitch and roll axes. Our design co-aligns the roll axis, and the line of sight therefore has a fixed entrance pupil position for all optical paths, unlike previously reported dual-FOV designs, which dispenses with image coregistration that is otherwise required. The fore-optics is essentially an achromatized, collimated beam reducer for all bands. Following the fore-optics, the bands are split into the dual-FOV IR path and the EO/laser path by a beam splitter. The subsequent dual-FOV IR path design consists of a zoom lens group and a relay lens group. The IR path with the fore-optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ to $5.40^{\circ}{\times}4.32^{\circ}$), due to the insertion of two Si lenses into the zoom lens group. The IR optical system is designed in such a way that the location and f-number (f/5.3) of the cold stop internally provided by the IR detector are maintained when changing the zoom. The design also satisfies several important performance requirements, including an on-axis modulation transfer function (MTF) that exceeds 10% at the Nyquist frequency of the IR detector pitch, with distortion of less than 2%.

FUNCTIONS AND DIFFERENTIAL OPERATORS IN THE DUAL REDUCED QUATERNION FIELD

  • Jung, Hyun Sook;Shon, Kwang Ho
    • East Asian mathematical journal
    • /
    • 제29권3호
    • /
    • pp.293-302
    • /
    • 2013
  • We research properties of ternary numbers and hyperholomorphic functions with values in $\mathbb{C}$(2). We represent reduced quaternion numbers and obtain some propertries in dual reduced quaternion systems in view of Clifford analysis. Moreover, we obtain Cauchy theorems with respect to dual reduced quaternions.

Design of a Light and Small Dual-band Airborne Despun Optical System

  • Luqing Zhang;Ning Zhang;Xiping Xu;Kailin Zhang;Yue Zhang;Jiachong Li
    • Current Optics and Photonics
    • /
    • 제8권1호
    • /
    • pp.97-104
    • /
    • 2024
  • In aerial cameras, image quality is easily affected by weather, temperature, and the attitude of the aircraft. Aiming at this phenomenon, based on the theory of two-step zoom optical systems, a dual-band optical-despun two-step zoom optical system is designed. The system has a small field of view of 2.00° × 1.60°, and a large field of view of 4.00° × 3.20°. In the zoom process, the wavelength range is 0.45-0.70 ㎛ and 0.75-1.10 ㎛, and the size of the optical system is 168 mm (L) × 90 mm (W) × 60 mm (H). The overall lens weight is only 170.8 g, which has advantages for miniaturization and light weight. At the Nyquist frequency of 104 lp/mm, the modulation transfer function of the visible-light optical system is more than 0.44, and that of the near-infrared optical system is more than 0.30, both of which have good imaging quality and tolerance characteristics in the range of -45 to 60 ℃.

반복 학습 제어를 이용한 NFR 디스크 드라이브의 2단 서보 시스템 (A Dual-Stage Servo System for an NFR Disk Drive using Iterative Learning Control)

  • 문정호;도태용
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.277-283
    • /
    • 2003
  • Recently, near-field recording (NFR) disk drive schemes have been proposed with a view to increasing recording densities of hard disk drives. Compared with hard disk drives. NFR disk drives have narrower track pitches and are exposed to more severe periodic disturbances resulting from eccentric rotation of the disk. It is difficult to meet servo system design specifications for NFR disk drives with conventional VCM actuators in that the servo system for an NFR disk drive generally requires a feater gain and higher bandwidth. To tackle the problem various dual-stage actuator systems composed of a microactuator mounted on top of a conventional VCM actuator have been proposed. This article deals with the problem of designing a tracking servo system far an NFR disk drive adopting a dual-stage actuator. We summarize design constraints pertaining to the dual-stage servo system and present a new servo scheme using iterative teaming control. We design feedback compensators and an iterative teaming controller for a target plant and verify the validity of the proposed control scheme through a computer simulation.

Maemi Dual Field Telescope System (MDFTS) : New survey facility of Kyung Hee Astronomical Observatory

  • Ahn, Hojae;Kim, Na Yeon;Kim, Dohoon;Pak, Soojong;Im, Myungshin
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.79.2-79.2
    • /
    • 2019
  • We introduce Maemi Dual Field Telescope System (MDFTS) which is newly installed at Kyung Hee Astronomical Observatory (KHAO). MDFTS consists of two telescope tubes (40cm and 10cm), whose observing fields are aligned with different field of view, 15' x 11' and 83' x 63' respectively. We present the specification of instruments (telescope, mount, camera, and filter system) and the observation environment of KHAO. We expect that MDFTS can be used for transient survey e.g. Intensive Monitoring Survey of Nearby Galaxies (IMSNG). Based on observations conducted so far, the limiting magnitude of 40cm telescope in B-band is B_lim ~ 16 mag at 5-σ detection with 150 seconds total integration time under dark and clear observing condition. Also the integrated observing software for MDFTS, KAOS40 is now under developing.

  • PDF

Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials

  • de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Cavalcanti, Yuri Wanderley;de Lima, Elisa Diniz;Bento, Patricia Meira;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.141-151
    • /
    • 2020
  • Purpose: This study aimed to quantify the influence of tooth position within the field-of-view (FOV) on cone-beam computed tomography (CBCT) imaging artifacts' intensity when assessing teeth restored with various intracanal materials. Materials and Methods: Seventy single-rooted teeth were divided into 7 groups (10 teeth per group): NiCr post (NC), AgPd post (AP), metal core fiberglass post (MCFG), fiberglass post (FG), anatomical fiberglass post (AFG), fiberglass post cemented with core build-up cement (FGCo), and anatomical fiberglass post cemented with core build-up cement (AFGCo). All posts were cemented using a regular dual-curing resin cement (Allcem), except FGCo and AFGCo which were cemented with a core build-up dual-curing resin cement (AllcemCore). Each tooth was scanned on a CS9000 in 5 positions within the FOV: a central position, anterior horizontal peripheral, peripheral superior, peripheral inferior, and posterior horizontal peripheral position. Hyperdense, hypodense, remaining teeth areas and ROI areas were quantitatively analyzed using ImageJ software. Results: Posterior horizontal peripheral position increased the intensity of artifacts on FGCo and AFGCo post groups (P<0.05), and specifically the hypodense artifact intensity on FG and AFG post groups (P<0.05). NC and AP groups presented greater intensity of artifacts than any other post groups(P<0.05). Conclusion: Artifact intensity increases in the presence of high atomic number materials and when the object is not centered within the FOV. The impact of positioning within the FOV on artifact was greater for fiberglass posts cemented with core build-up dual-curing cement than for metal posts and fiberglass posts cemented with regular dual-curing cement.

CAN네트워크를 이용한 단일 프로세서에 의한 복수전동기 구동 (A Study on Driving Dual Motors with Single processor using Controller Area Network)

  • 이홍희;이승용;정의헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.673-676
    • /
    • 2002
  • Real time communication is very important in factory automation system using FieldBus. In this paper, we Propose the method to drive dual motors with one controller using CAN In traditional induction motor control technique, two independent Inverters are used to drive dual motors independently. In this case, two controllers are needed. Our proposed dual motors control scheme which use only one microprocessor has many advantages in the view of economic and performance compared to conventional technique.

  • PDF

전계방사형 주사전자현미경에 의한 연속블록면 이미징 (Serial Block-Face Imaging by Field Emission Scanning Electron Microscopy)

  • 김기우
    • Applied Microscopy
    • /
    • 제41권3호
    • /
    • pp.147-154
    • /
    • 2011
  • 후방산란전자(BSE)는 입사전자빔이 시료와 충돌하면서 발생한다. BSE 이미징은 시료의 화학적 특성을 구분할 수 있는 조성대비를 제공한다. 집속이온빔장치(FIB)는 전계방사형 주사전자현미경(FESEM)과 결합할 수 있으므로 이중빔 체계(FIB-FESEM)가 구현된다. 갈륨(Ga) 이온빔으로 10~100 nm 두께로 시료를 절삭할 수 있으므로 FIB-FESEM은 플라스틱으로 포매된 블록의 면을 z축 고해상도를 유지하며 연속적으로 이미징할 수 있다. BSE이미지의 대비를 반전시키면 투과전자현미경의 이미지와 유사하다. 연속블록면 이미징의 또 다른 방안으로써 특수한 초박절편기가 FESEM 내부에 장착된 것이 $3View^{(R)}$로 상용화되어 있다. 이로써 플라스틱으로 포매된 시료의 내부 구조를 넓은 면적을 연속적으로 이미징 할 수 있으므로 3차원 재구성도 용이하게 된다. 이러한 FESEM에 기반한 두 가지 방식은 복잡한 생물계의 총체적인 이해를 위하여 세포 및 세포 수준 이하의 구조물 간의 공간적 연관성을 규명하는 데 활용될 수 있다.

Standard Calibration for Broadband and Narrowband Filters of KHAO 0.4 m Telescope

  • Ahn, Hojae;Jeong, Inhwan;Paek, Gregory S.H.;Lee, Sumin;Kim, Changgon;Pak, Soojong;Shim, Hyunjin;Im, Myungshin
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.76.1-76.1
    • /
    • 2021
  • Maemi Dual Field Telescope System (MDFTS) is a dual telescope system located at Kyung Hee University. The system consists of 0.4 m telescope and 0.1 m telescope for wide-field observation. The 0.4 m telescope provides photometric observation which covers a field of view of 21'×16'. It has been used for various purposes with Johnson-Cousins UBVRI broadband filter system, e.g., SomangNet and Intensive Monitoring Survey of Nearby Galaxies. In this poster, we present the standard calibration result for our broadband filter system. Also, we suggest a new usage of the KHAO 0.4m telescope which is narrowband photometry by demonstrating the standard calibration of H-alpha filter. For flux calibration, not only R filter but also V filter is used for compensating the central wavelength discrepancy between R filter and H-alpha filter.

  • PDF

듀얼 모드(고정형+PTZ 카메라) 감시 카메라를 이용한 효과적인 화상 감시 시스템에 관한 연구 (Study on Effective Visual Surveillance System using Dual-mode(Fixed+Pan/Tilt/Zoom) Camera)

  • 김기석;이삭;박종섭;조재수
    • 제어로봇시스템학회논문지
    • /
    • 제18권7호
    • /
    • pp.650-657
    • /
    • 2012
  • An effective dual-mode camera system(a passive wide-angle camera and a pan-tilt-zoom camera) is proposed in order to improve the performance of visual surveillance. The fixed wide-angle camera is used to monitor large open areas, but the moving objects on the images are too small to view in detail. And, the PTZ camera is capable of increasing the monitoring area and enhancing the image quality by tracking and zooming in on a specific moving target. However, its FOV (Field of View) is limited when zooming in on a specific target. Therefore, the cooperation of wide-angle and PTZ cameras is complementary. In this paper, we propose an automatic initial set-up algorithm and coordinate transform method from the wide-angle camera coordinate to the PTZ one, which are necessary to achieve the cooperation. The automatic initial set-up algorithm is able to synchronize the views of two cameras. When a moving object appears on the image plane of a wide-angle camera after the initial set-up positioning, the obtained values of the wide-angle camera should be transformed to the PTZ values based on the coordinate transform method. We also develope the PTZ control method. Various in-door and out-door experiments show that the proposed dual-camera system is feasible for the effective visual surveillance.