• 제목/요약/키워드: Dual rate

검색결과 813건 처리시간 0.025초

실시간 시뮬레이션을 위한 병렬적분 (Parallel Integration for Real-Time Simulation)

  • 이운성
    • 한국자동차공학회논문집
    • /
    • 제2권1호
    • /
    • pp.106-115
    • /
    • 1994
  • A parallel integration approach is proposed for real-time simulation of controlled mechanical systems. The proposed approach, which employs the dual-rate integration method in a parallel computing environment, is developed to deal with stiffness and high frequency characteristics of the controlled mechanical systems effectively. Numerical experiments are performed to demonstrate the effectiveness of the approach in shared memory multiprocessors, Alliant FX/8 and Alliant FX/80.

  • PDF

포유자돈에서 돼지써코바이러스 2형이 돼지유행성설사 바이러스 감염에 미치는 영향 - I. 혈청학적 결과, 형광항체검사 및 RT-PCR 검사 - (Effects of porcine circovirus type 2 on the pathogenesis of porcine epidemic diarrhoea virus infection in piglets - I. Serological result, FA test and RT-PCR -)

  • 김문;김영훈;한정희
    • 한국동물위생학회지
    • /
    • 제32권3호
    • /
    • pp.177-187
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of a subsequent infection of PCV2 on piglets with PEDV. The results obtained were as follows: Antibodies against PCV2 and PEDV were detected at 24, 36, 48, 60 and 72h postinfection. And the antibody titers of alone infections with PEDV were gradually reduced and increased from 60 hpi to 72 hpi. Whereas, the antibody titers of dual infections with PCV2 and PEDV were gradually reduced all the time. PEDV antigens were detected at 24, 36, 48, 60 and 72 hpi, being seen almost exclusively in feces and small intestines from PEDV-infected piglets and PCV2-coinfected piglets. The detection rate of PEDV in feces and jejunum tissues by RT-PCR were 94.9% and 91.1% in dual infections and 87.1% and 83.6% in alone infections with PEDV, respectively. In dual infected piglets, significantly more PEDV antigens were detected in the feces and small intestines tissues at 24 hpi (P<0.05) than in the same feces and tissues of the alone infected piglets. Thereafter, at 72 hpi significantly more PEDV antigens (P<0.05) was detected in the jejunal tissues of the dual infected piglets with than of alone PEDV-infected piglets. The detection rate of PEDV antigen in the duodenum, jejunum and ileum by IFA were 91.3%, 91.3% and 83.3% in dual infected piglets and 75.0%, 83% and 75% in alone infected piglets, respectively. Intense and specific fluorescence signals were more often seen within jejunal villous enterocytes in dual infected piglets than alone infected piglets.

Effect of a dual trigger on oocyte maturation in young women with decreased ovarian reserve for the purpose of elective oocyte cryopreservation

  • Kim, Se Jeong;Kim, Tae Hyung;Park, Jae Kyun;Eum, Jin Hee;Lee, Woo Sik;Lyu, Sang Woo
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제47권4호
    • /
    • pp.306-311
    • /
    • 2020
  • Objective: The aim of this study was to determine whether co-administration of a gonadotropin-releasing hormone (GnRH) agonist and human chorionic gonadotropin (hCG) for final oocyte maturation improved mature oocyte cryopreservation outcomes in young women with decreased ovarian reserve (DOR) compared with hCG alone. Methods: Between January 2016 and August 2019, controlled ovarian stimulation (COS) cycles in women (aged ≤35 years, anti-Müllerian hormone [AMH] <1.2 ng/mL) who underwent elective oocyte cryopreservation for fertility preservation were retrospectively analyzed. Results: A total of 76 COS cycles were triggered with a GnRH agonist and hCG (the dual group) or hCG alone (the hCG group). The mean age and serum AMH levels were comparable between the two groups. The duration of stimulation, total dose of follicle-stimulating hormone used, and total number of oocytes retrieved were similar. However, the number of mature oocytes retrieved and the oocyte maturation rate were significantly higher in the dual group than in the hCG group (p=0.010 and p<0.001). After controlling for confounders, the dual-trigger method remained a significant factor related to the number of mature oocytes retrieved (p=0.016). Conclusion: We showed improved mature oocyte collection and maturation rate with the dual triggering of oocyte maturation in young women with DOR. A dual trigger appears to be more beneficial than hCG alone in terms of mature oocyte cryopreservation for young women with DOR.

심층여과지의 여층구성에 따른 여과특성 비교 (Characteristics of Depth Filtration for Various Filter-Bed Configurations)

  • 안종호;윤재흥
    • 한국수자원학회논문집
    • /
    • 제34권5호
    • /
    • pp.459-472
    • /
    • 2001
  • 모형실험장치를 이용하여 심층여과지에 대한 여층구성별 여과효율 평가를 통해 여과지 설계시의 여층구성에 대한 기초자료를 제공하는 것이 본 연구의 목적이다. 여과지속시간에 따른 손실수두 발달특성을 보면 여과초기의 수두손실은 이중여재 여과지가 높지만 탁질 억류에 의한 수두손실의 증가는 완만하여 여과속도 180 m/day의 동일한 여과속도를 적용하였을 경우, 조림심층 모래여과지에 비해 단위정수생산량이 30-40% 정도 증대되는 것으로 나타났다. 여과수질은 각각 여과속도 180 m/day, 240 m/day로 운전한 결과 여과속도에 관계없이 모두 0.1 NTU 이하를 나타내어 만족하는 여과수질을 보였다. 그러나 여과초기 탁질 누출 특성을 보면 상대적으로 조립심층 모래여과지의 누출 경향이 크게 나타났고, 여과속도 240 m/day로 증대됨에 따라 그 경향은 보다 뚜렷하게 나타났다.

  • PDF

Discrete-Time Queuing Analysis of Dual-Plane ATM Switch with Synchronous Connection Control

  • Choi, Jun-Kyun
    • ETRI Journal
    • /
    • 제19권4호
    • /
    • pp.326-343
    • /
    • 1997
  • In this paper, we propose an ATM switch with the rate more than gigabits per second to cope with future broadband service environments. The basic idea is to separate the connection control flow from the data information flow inside the switch. The proposed switch has a dual-plane switch matrix with the synchronous control algorithm. The queuing behaviors of the proposed switch are shown by the discrete-time queuing analysis. Numerical analyses are taken both in the non-blocking crossbar switch and the banyan switch with internal blocking. Results show that a proposed dual-plane $16{\times}16$ switch would have the acceptable performance with maximum throughput of about 95 percent.

  • PDF

3.5% NaCl 수용액의 온도변화가 복합조직강의 부식피로파괴에 미치는 영향 (The Effects of 3.5% NaCl Aqueous Solution Temperature on the Corrosion Fatigue Fracture of Dual phase steel)

  • 오세욱;도영문;박수영;김재철;김광영
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.140-147
    • /
    • 1992
  • Corrsion fatigue test was performed under rotated bending in 3.5% NaCl aqueous solution having a temperature from 278.deg.K in order to investigate the effects of aqueous solution remperature on the corrosion fatigue fracture of raw material steel(SS41) and dual phase steel that was produced from SS41 by a series of heat treatment. Corrosion fatigue life decreases remarkably with increase in solution temperature or with decrease in stress level. The corrosion fatigue life and the crack propagation rate at 303.deg.K show the similar behaviors with those at 318.deg.K, which is assumed to be caused by concentration polarization phenamena. The number and the lengths of microcracks increase with increase in solution temperature, so they lead to the decrease in corrosion fatigue life.

  • PDF

이중 편파 다중 안테나를 이용한 다중 사용자 전송 (Multi-User Transmission Exploiting Multiple Dual-Polarized Antennas)

  • 신창용;박윤옥
    • 한국통신학회논문지
    • /
    • 제39A권12호
    • /
    • pp.774-776
    • /
    • 2014
  • 본 논문은 가시선 (line-of-sight) 성분이 지배적인 채널 환경에서 다중 사용자로의 정보 전송을 위해 이중 편파를 이용하는 다중 안테나 시스템을 제안한다. 이 시스템은 공간 및 편파 자원을 효율적으로 활용하여 기존의 단일 편파 안테나를 이용하는 MU-MIMO(multi-user multiple input multiple output) 시스템 보다 향상된 총 전송률을 제공할 수 있음을 보인다

Channel Coding-Aided Multi-Hop Transmission for Throughput Enhancement

  • Hwang, Inchul;Wang, Hanho
    • International Journal of Contents
    • /
    • 제12권1호
    • /
    • pp.65-69
    • /
    • 2016
  • Wireless communication chipsets have fixed transmission rate and communication distance. Although there are many kinds of chipsets with throughput and distance purpose, they cannot support various types of wireless applications. This paper provides theoretic research results in order to support various wireless applications requiring different throughput, delayed quality-of-service (QoS), and different communication distances by using a wireless communication chipset with fixed rate and transmission power. As a performance metric, the probability for a data frame that successfully receives at a desired receiver is adopted. Based on this probability, the average number of transmission in order to make a successful frame transmission is derived. Equations are utilized to analyze the performance of a single-hop with channel coding and a dual-hop without error correction matter transmission system. Our results revealed that single-hop transmission assisted by channel coding could extend its communication distance. However, communication range extending effect of the single-hop system was limited. Accordingly, dual-hop transmission is needed to overcome the communication distance limit of a chipset.

A 2.7Gbps & 1.62Gbps Dual-Mode Clock and Data Recovery for DisplayPort in $0.18{\mu}m$ CMOS

  • Lee, Seung-Won;Kim, Tae-Ho;Lee, Suk-Won;Kang, Jin-Ku
    • 전기전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.40-46
    • /
    • 2010
  • This paper describes a clock and data recovery (CDR) circuit that supports dual data rates of 2.7Gbps and 1.62Gbps for DisplayPort standard. The proposed CDR has a dual mode voltage-controlled oscillator (VCO) that changes the operating frequency with a "Mode" switch control. The chip has been implemented using $0.18{\mu}m$ CMOS process. Measured results show the circuit exhibits peak-to-peak jitters of 37ps(@2.7Gbps) and 27ps(@1.62Gbps) in the recovered data. The power dissipation is 80mW at 2.7Gbps rate from a 1.8V supply.

이중응집이 응집공정에 미치는 영향 (Effects of Dual-Coagulant Performance)

  • 김희근;문병현;김승현
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.92-97
    • /
    • 2005
  • This research is to investigate the effect of the dual coagulant using inorganic coagulants($AICl3{\cdot}6H2O$) and polymer on the coagulant process. Jar-test was conducted by using Kaolin injected raw water. PDA(Photometric Dispersion Analyzer) equipment in order to analyze the size of the particles and the characteristics of the shapes. The change in the rate of sample ores' residual deposited after coagulants were also compared. According to the result derived from this experiment, the concentration of inorganic coagulant reduced 50% and the residual was lower by using dual coagulants compared to using single coagulant. However the dual coagulant required sufficient mixing time, and affected particle characteristics, with the effect of the injection order of coagulants, the simultaneous injection of inorganic coagulant and polymer showed the most effective in the particle removal.