Characteristics of Depth Filtration for Various Filter-Bed Configurations

심층여과지의 여층구성에 따른 여과특성 비교

  • An, Jong-Ho (Water Resources Research Center, Korea Water Resources Corporation) ;
  • Yun, Jae-Heung (Water Resources Research Center, Korea Water Resources Corporation)
  • 안종호 (한국수자원공사 수자원연구소) ;
  • 윤재흥 (한국수자원공사 수자원연구소)
  • Published : 2001.10.01

Abstract

The objective of this study is to evaluate the filtration efficiency of deep-bed filters by comparing to single and dual media filters. Pilot-plant tests using four-filter columns were conducted for the comparison of head loss development and filtered water quality. The dual-media filter showed greater initial head loss, but less rate of head-loss development than those of the coarse-sand-0deep-bed filters. For 180 m/day of filtration rate, the dual-media filter produces larger unit production rate by 30-40%, and the turbidities of filtered water were below 0.1 NTU. The initial breakthrough could be effectively controlled by the dual-media filter rather than coarse-sand-deep-bed filters.

모형실험장치를 이용하여 심층여과지에 대한 여층구성별 여과효율 평가를 통해 여과지 설계시의 여층구성에 대한 기초자료를 제공하는 것이 본 연구의 목적이다. 여과지속시간에 따른 손실수두 발달특성을 보면 여과초기의 수두손실은 이중여재 여과지가 높지만 탁질 억류에 의한 수두손실의 증가는 완만하여 여과속도 180 m/day의 동일한 여과속도를 적용하였을 경우, 조림심층 모래여과지에 비해 단위정수생산량이 30-40% 정도 증대되는 것으로 나타났다. 여과수질은 각각 여과속도 180 m/day, 240 m/day로 운전한 결과 여과속도에 관계없이 모두 0.1 NTU 이하를 나타내어 만족하는 여과수질을 보였다. 그러나 여과초기 탁질 누출 특성을 보면 상대적으로 조립심층 모래여과지의 누출 경향이 크게 나타났고, 여과속도 240 m/day로 증대됨에 따라 그 경향은 보다 뚜렷하게 나타났다.

Keywords

References

  1. 일본수도협회 (1982). 수도시설 실계지침
  2. 한국수도협회 (1989). 한국수도협회규격
  3. 환경부 (1997). 기존정수장 효율향상기술(2차년도)
  4. 환경부 (1998). 상수도시설기준
  5. Amirtharajah, A. (1991). 'Optimum Backwash of Dual Media Filters and GAC Filter-Adsorbers with Air Scour.' AWWARF, Denver, AWWA
  6. Barnett, E., et al. (1992). 'Comparing Plant-Scale Dual and Mixed-Media Filters.' Jour. AWWA, 84(6), p.76
  7. Bracher of Australian C & S Brand Filter Coal. (1997)
  8. Degremont. (1979). Water Treatment Handbook. 5th edition, Degrerront
  9. Kawamura, Susumu (1991). Integrated Design of Water Treatment Facilities. John Wiley & Sons, Inc.
  10. Logsdon, G. A. and Symons, J. M. (1977). 'Removal of Asbestiforrn Fibers by Water Filtration.' Jour. AWWA, 69(6), p.499
  11. Peterson, D. L., Schleppenbach, R. X. and Zandtke, T. M. (1980). 'Studies of Asbestos Removal by Direct Filtration of Lake Superior Water.' Jour. AWWA, 72(3), p.155
  12. Qureshi, N. (1981). 'Comparative Performance of Dual and Mixed Media Filters.' Jour. AWWA, 73(9), p.490
  13. Sanks, Robert L. (1979). Water Treatment Plant Design. Ann Arbor Science