• 제목/요약/키워드: Dual modality

검색결과 23건 처리시간 0.027초

Alcohol neurolysis of genicular nerve for chronic knee pain

  • Dass, Rushin Maria;Kim, Eunsoo;Kim, Hae-kyu;Lee, Ji Youn;Lee, Hyun Ju;Rhee, Seung Joon
    • The Korean Journal of Pain
    • /
    • 제32권3호
    • /
    • pp.223-227
    • /
    • 2019
  • Radiofrequency neurolysis (RFN) of the genicular nerves has recently become accepted as an effective technique to alleviate knee pain particularly in patients with knee osteoarthritis (OA) or postoperative pain. However, genicular nerve RFN can produce high procedure and equipment costs, longer procedural times, procedure-related pain, and failure rate of over 25%. We are presenting two cases of alcohol neurolysis of the genicular nerve using fluoroscopy and ultrasonography in patients with knee OA or persistent postsurgical pain of the knee. Alcohol neurolysis of the genicular nerve with dual imaging modality can be a cheap, safe and effective method in patients with chronic knee pain.

The Effects of Multi-Modality on the Use of Smart Phones

  • Lee, Gaeun;Kim, Seongmin;Choe, Jaeho;Jung, Eui Seung
    • 대한인간공학회지
    • /
    • 제33권3호
    • /
    • pp.241-253
    • /
    • 2014
  • Objective: The objective of this study was to examine multi-modal interaction effects of input-mode switching on the use of smart phones. Background: Multi-modal is considered as an efficient alternative for input and output of information in mobile environments. However, there are various limitations in current mobile UI (User Interface) system that overlooks the transition between different modes or the usability of a combination of multi modal uses. Method: A pre-survey determined five representative tasks from smart phone tasks by their functions. The first experiment involved the use of a uni-mode for five single tasks; the second experiment involved the use of a multi-mode for three dual tasks. The dependent variables were user preference and task completion time. The independent variable in the first experiment was the type of modes (i.e., Touch, Pen, or Voice) while the variable in the second experiment was the type of tasks (i.e., internet searching, subway map, memo, gallery, and application store). Results: In the first experiment, there was no difference between the uses of pen and touch devices. However, a specific mode type was preferred depending on the functional characteristics of the tasks. In the second experiment, analysis of results showed that user preference depended on the order and combination of modes. Even with the transition of modes, users preferred the use of multi-modes including voice. Conclusion: The order of combination of modes may affect the usability of multi-modes. Therefore, when designing a multi-modal system, the fact that there are frequent transitions between various mobile contents in different modes should be properly considered. Application: It may be utilized as a user-centered design guideline for mobile multi modal UI system.

핵의학 영상기기의 최근 진보 (Recent Advances in Nuclear Medicine Imaging Instrumentation)

  • 정진호;최용;홍기조;민병준;호위;강지훈
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

PHA-Induced Peripheral Blood Cytogenetics and Molecular Anslysis : a Valid Diagnostic and Follow-up Modality For Acute Primyelocytic Leukemia Patients Treated With ATRA and/or Arsenic Tri-oxide

  • Baba, Shahid M;Azad, Niyaz A;Shah, Zaffar A;Afroze, Dil;Pandith, Arshad A;Jan, Aleem;Aziz, Sheikh A;Dar, Fayaz A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.1999-2006
    • /
    • 2016
  • Background: Acute promyelocytic leukemia (APML) is characterized by the reciprocal translocation t(15;17) (p22;p12) resulting in the PML-$RAR{\alpha}$ fusion gene. A dual diagnostic and follow up approach was applied including cytogenetic demonstration of the t(15;17) translocation and detection dg PML-$RAR{\alpha}$ chimeric transcripts by molecular means. Purpose: Conventional cytogenetics involving bone marrow is beset with high probability of poor metaphase index and was substituted with phytohemagglutinin (PHA)-induced peripheral blood culture based cytogenetic analysis as a diagnostic & follow up modality in APML patients of Kashmir (North India). Both qualitative (RT-PCR) and quantitative (Q-PCR) tests were simultaneously carried out to authenticte the modified cytogenetics. Materials and Method: Patient samples were subjected to the said techniques to establish their baseline as well as follow-up status. Results: Initial cytogenetics revealed 30 patients (81%) Positive for t(15;17) whereas 7 (19%) had either cryptic translocation or were negative for t(15;17). Two cases had chromosome 16q deletion and no hallmark translocation t(15;17). Q-PCR status for PML-$RAR{\alpha}$ was found to be positive for all patients. All the APML patients were reassessed at the end of consolidation phase and during maintenance phase of chemotherapy where 6 patients had molecular relapse, wherein 4 also demonstrated cytogenetic relapse. Conclusions: It was found that PHA-induced peripheral blood cytogenetics along with molecular analysis could prove a reliable modality in the diagnosis and assessment of follow up response of APML patients.

최근 핵의학 영상 기기 발전 동향 (Recent Developments in Nuclear Medicine Instrumentation)

  • 김준영;최용;김종호;임기천;최연성;이경한;김상은;김병태
    • 대한핵의학회지
    • /
    • 제32권6호
    • /
    • pp.471-481
    • /
    • 1998
  • The goals of developments in nuclear medicine instrumentation are to offer a higher-quality image and to aid diagnosis, prognosis assessment or treatment planning and monitoring. It is necessary for physicists and engineers to improve or design new instrumentation and techniques, and to implement, validate, and apply these new approaches in the practice of nuclear medicine. The researches in physical properties of detectors and crystal materials and advances in image analysis technology have improved quantitative and diagnostic accuracy of nuclear medicine images. This review article presents recent developments in nuclear medicine instrumentation, including scatter and attenuation correction, new detector technology, tomographic image reconstruction methods, 511 keV imaging, dual modality imaging device, small gamma camera, PET developments, image display and analysis methods.

  • PDF

Effects of Somatostatin on the Responses of Rostrally Projecting Spinal Dorsal Horn Neurons to Noxious Stimuli in Cats

  • Jung, Sung-Jun;Jo, Su-Hyun;Lee, Sang-Hyuck;Oh, Eun-Hui;Kim, Min-Seok;Nam, Woo-Dong;Oh, Seog-Bae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제12권5호
    • /
    • pp.253-258
    • /
    • 2008
  • Somatostatin (SOM) is a widely distributed peptide in the central nervous system and exerts a variety of hormonal and neural actions. Although SOM is assumed to play an important role in spinal nociceptive processing, its exact function remains unclear. In fact, earlier pharmacological studies have provided results that support either a facilitatory or inhibitory role for SOM in nociception. In the current study, the effects of SOM were investigated using anesthetized cats. Specifically, the responses of rostrally projecting spinal dorsal horn neurons (RPSDH neurons) to different kinds of noxious stimuli (i.e., heat, mechanical and cold stimuli) and to the $A{\delta}$ -and C-fiber activation of the sciatic nerve were studied. Iontophoretically applied SOM suppressed the responses of RPSDH neurons to noxious heat and mechanical stimuli as well as to C-fiber activation. Conversely, it enhanced these responses to noxious cold stimulus and $A{\delta}$-fiber activation. In addition, SOM suppressed glutamate-evoked activities of RPSDH neurons. The effects of SOM were blocked by the SOM receptor antagonist cyclo-SOM. These findings suggest that SOM has a dual effect on the activities of RPSDH neurons; that is, facilitation and inhibition, depending on the modality of pain signaled through them and its action site.

관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가 (The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography)

  • 최남길;최재성;한재복
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4411-4417
    • /
    • 2010
  • 64채널 MDCT(multidetector computed tomography)와 128채널 DSCT(dual source computed tomography)를 이용한 관상동맥 전산화단층촬영 시 유효선량과 획득한 영상의 질을 평가함으로서 임상에서의 유용성을 평가하고자 하였다. 피폭선량은 선량길이곱(dose length product: DLP)에 흉부 조직의 가중치(0.017)을 곱하여 유효선량(mSv)으로 계산하였으며, 영상 평가는 심장촬영검사 후 영상의학과 전문의가 5점 Likert 척도(5점 최상)로 평가하였다. DLP 값은 64 채널 MDCT에서는 $851{\sim}1277\;mGy{\cdot}cm$ (평균 유효선량: 17.23mSv), 128 채널 DSCT에서는 $82{\sim}110\;mGy{\cdot}cm$ (평균 유효선량: 1.58mSv)로 각각 분포하였다. 영상 평가점수는 64 채널 MDCT에서 $3.31{\pm}0.62$(4점 이상 34명), 128channel DSCT에서 $4.05{\pm}0.46$(4점 이상 96명)으로 각각 나타났다. 유효선량은 64채널 MDCT에 비해 128채널 DSCT가 1/10 이상 감소함을 알 수 있었다. 영상 평가점수는 통계적으로 유의한 차이를 보였으며 4점 이상 점수의 빈도는 128채널 DSCT에서 2.8배 높게 나타났다. 결론적으로 관상동맥 전산화단층촬영검사에서는 128채널 DSCT가 64채널 MDCT에 비해 환자가 받는 유효선량은 감소하고 영상 평가점수는 높게 나타나 임상에서 보다 유용할 것으로 판단된다.

Machine Learning Model to Predict Osteoporotic Spine with Hounsfield Units on Lumbar Computed Tomography

  • Nam, Kyoung Hyup;Seo, Il;Kim, Dong Hwan;Lee, Jae Il;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.442-449
    • /
    • 2019
  • Objective : Bone mineral density (BMD) is an important consideration during fusion surgery. Although dual X-ray absorptiometry is considered as the gold standard for assessing BMD, quantitative computed tomography (QCT) provides more accurate data in spine osteoporosis. However, QCT has the disadvantage of additional radiation hazard and cost. The present study was to demonstrate the utility of artificial intelligence and machine learning algorithm for assessing osteoporosis using Hounsfield units (HU) of preoperative lumbar CT coupling with data of QCT. Methods : We reviewed 70 patients undergoing both QCT and conventional lumbar CT for spine surgery. The T-scores of 198 lumbar vertebra was assessed in QCT and the HU of vertebral body at the same level were measured in conventional CT by the picture archiving and communication system (PACS) system. A multiple regression algorithm was applied to predict the T-score using three independent variables (age, sex, and HU of vertebral body on conventional CT) coupling with T-score of QCT. Next, a logistic regression algorithm was applied to predict osteoporotic or non-osteoporotic vertebra. The Tensor flow and Python were used as the machine learning tools. The Tensor flow user interface developed in our institute was used for easy code generation. Results : The predictive model with multiple regression algorithm estimated similar T-scores with data of QCT. HU demonstrates the similar results as QCT without the discordance in only one non-osteoporotic vertebra that indicated osteoporosis. From the training set, the predictive model classified the lumbar vertebra into two groups (osteoporotic vs. non-osteoporotic spine) with 88.0% accuracy. In a test set of 40 vertebrae, classification accuracy was 92.5% when the learning rate was 0.0001 (precision, 0.939; recall, 0.969; F1 score, 0.954; area under the curve, 0.900). Conclusion : This study is a simple machine learning model applicable in the spine research field. The machine learning model can predict the T-score and osteoporotic vertebrae solely by measuring the HU of conventional CT, and this would help spine surgeons not to under-estimate the osteoporotic spine preoperatively. If applied to a bigger data set, we believe the predictive accuracy of our model will further increase. We propose that machine learning is an important modality of the medical research field.

다중 감각 단서가 촉각적 심상과 제품에 대한 태도-구매 의사에 미치는 영향 (Effect of Multimodal cues on Tactile Mental Imagery and Attitude-Purchase Intention Towards the Product)

  • 이예진;한광희
    • 감성과학
    • /
    • 제24권3호
    • /
    • pp.41-60
    • /
    • 2021
  • 본 연구는 제품과 물리적 접촉이 불가능한 온라인 환경에서 다중 감각 단서가 소비자의 촉각적 심상과 제품에 대한 태도 및 구매 의사에 미치는 영향을 알아보고자 하였다. 실험 1에서는 참가자들을 음향 없이 사진만 제시한 조건, 음향 없이 영상만 제시한 조건, 일치하는 음향과 영상을 제시한 조건, 불일치하는 음향과 영상을 제시한 조건으로 나누어 제품을 탐색하게 하였고 그 후 촉각적 심상선명도, 제품 사용의 상상용이성, 제품에 대한 태도-구매 의사를 측정하였다. 그 결과, 모든 변수에서 불일치하는 음향과 영상이 주어진 조건이 가장 낮은 평균 점수를 보였다. 실험 2는 참가자 내 디자인으로 설계되어, 참가자들에게 동일한 제품을 실험 1과 같은 네 개의 조건에서 탐색하게 하였다. 탐색 후, 촉각적 심상선명도, 제품 사용의 상상용이성, 제품에 대한 태도-구매 의사, 접촉 욕구 등을 측정하였다. 접촉 욕구를 공변인으로 하는 반복측정 공분산분석 결과, 일치하는 음향과 영상을 제시한 조건은 다른 조건과 비교했을 때 유의미하게 심상선명도, 제품에 대한 태도, 제품 구매 의사가 높았다. 이중 매개 분석 결과, 다중 감각 단서 조건은 심상선명도와 제품 사용의 상상용이성을 순차적으로 매개하여 제품에 대한 태도-구매 의사를 유의미하게 예측했다. 결론적으로, 음향 및 영상 단서로 유발된 선명한 촉각적 심상은 소비자가 제품을 사용하는 상황의 상상을 쉽게 만들어 태도-구매 의사와 같은 의사 결정에 긍정적 영향을 미칠 수 있다.

약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구 (Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study)

  • 김빛별;김호경;김진성;기용간;주지현;전호상;박달;김원택;남지호;김동현
    • 대한영상의학회지
    • /
    • 제82권6호
    • /
    • pp.1477-1492
    • /
    • 2021
  • 목적 Dedicated breast CT (이하 DBCT)는 유방 압박의 고통이 없는 영상 진단 기법으로 최근 주목받고 있다. 본 연구에서는 DBCT 영상에서 약하게 조영증강된 작은 병변의 검출률을 높이기 위해 피사체의 기하학적 정보를 이용하여 최적의 영상 문턱값을 제공하는 adaptive image rescaling (이하 AIR) 기법을 제안하였다. 대상과 방법 5개의 동일 크기의 구멍과 서로 다른 크기의 구멍을 가지는 두 개의 디스크를 각각 제작하고, 이를 60 kVp와 100 kVp로 스캔하여 single-energy CT (이하 SECT), dual-energy CT (이하 DECT), 그리고 AIR 영상을 생성하였다. 전임상 평가를 위해 돼지 조직 영상도 획득하였다. Image contrast (이하 IC)와 contrast-to-noise ratio (이하 CNR)로 화질을 평가하였으며, student's t test를 이용하여 영상 간 화질의 차이를 검증하였다. 결과 AIR의 평균 IC (0.70)는 DECT (0.94)의 74.5%로 나타났으며, SECT (0.22) 보다 318.2% 높았다. 또한 AIR의 평균 CNR (5.08)은 SECT (14.30)의 35.5%로 나타났고 DECT (2.28) 보다 222.8% 높게 측정되었다. 돼지 조직의 전임상 평가 결과도 비슷한 양상을 보였다. 결론 AIR은 SECT보다 높은 영상 대조도를 가지며, 50% 선량만으로도 DECT에 비견할 만한 화질 성능을 제공할 수 있음을 확인하였다. 따라서 AIR은 DBCT 영상에서 약하게 조영증강된 병변의 검출률을 개선할 수 있을 것으로 생각된다.