• 제목/요약/키워드: Dual modality

검색결과 23건 처리시간 0.032초

제시양식 및 부호화조건과 단서양식이 아동의 회상에 미치는 영향 (Effects of Presentation Modality, Encoding Condition and Cue Modality on Child Recall)

  • 박명자;최경숙
    • 아동학회지
    • /
    • 제11권1호
    • /
    • pp.45-57
    • /
    • 1990
  • The purpose of the present study was to investigate the age-related differences in recall and to assess effects of presentation modality, encoding condition and cue modality on recall in terms of encoding specificity principles and dual-coding theory. Eighty children in each of 3grades(first, third and fifth) were presented a 30-item set of pictures or words on cars for recall in a study-test procedure. The experiment was designed as a 3(age) x 2(presentation modality:picture or word) x 2(encoding condition:random or category) x 2(cue modality:picuture or word) factorial design. Statistical analyses were with four-way ANOVA and $Scheff\acute{e}$ test. It was concluded from these results that when the stimulus was presented by pictures, encoded by category and the cues were also presented by pictures, recall increased in all ages. These results were interpreted in terms of encoding specificity principles and dual-coding theory.

  • PDF

Synthesis of a squaric acid-derived molecular probe for near-infrared fluorescence and photoacoustic imaging

  • Jung Eun Park;Yong Dae Park;Jongho Jeon
    • 대한방사성의약품학회지
    • /
    • 제6권2호
    • /
    • pp.177-181
    • /
    • 2020
  • Dual-modality imaging strategy using near-infrared fluorescence (FLI) and photoacoustic imaging (PAI) demands a suitable probe to enable dual-modular signal production. Herein, we demonstrate a synthetic protocol of small molecular dye for dual-modular FLI and PAI. A condensation reaction between squaric acid and carboxypentyl benzoindolium, and followed by basic hydrolysis to give the benzoindole derived squaraine (BSQ) dye in 49% yield. Next, the carboxylic acid group of BSQ was further functionalized with N-hydroxysuccinimide or azide group for an efficient conjugation with a targeting biomolecule. BSQ showed a maximum fluorescent emission at around 680 nm and the photoacoustic signal reached a maximum intensity at 680-700 nm. Based on these results, we conclude that BSQ analogs will be useful probes for dual-modular (FLI/PAI) imaging studies in animal models.

멀티모달 인터랙션을 위한 사용자 병렬 모달리티 입력방식 및 입력 동기화 방법 설계 (Design of Parallel Input Pattern and Synchronization Method for Multimodal Interaction)

  • 임미정;박범
    • 대한인간공학회지
    • /
    • 제25권2호
    • /
    • pp.135-146
    • /
    • 2006
  • Multimodal interfaces are recognition-based technologies that interpret and encode hand gestures, eye-gaze, movement pattern, speech, physical location and other natural human behaviors. Modality is the type of communication channel used for interaction. It also covers the way an idea is expressed or perceived, or the manner in which an action is performed. Multimodal Interfaces are the technologies that constitute multimodal interaction processes which occur consciously or unconsciously while communicating between human and computer. So input/output forms of multimodal interfaces assume different aspects from existing ones. Moreover, different people show different cognitive styles and individual preferences play a role in the selection of one input mode over another. Therefore to develop an effective design of multimodal user interfaces, input/output structure need to be formulated through the research of human cognition. This paper analyzes the characteristics of each human modality and suggests combination types of modalities, dual-coding for formulating multimodal interaction. Then it designs multimodal language and input synchronization method according to the granularity of input synchronization. To effectively guide the development of next-generation multimodal interfaces, substantially cognitive modeling will be needed to understand the temporal and semantic relations between different modalities, their joint functionality, and their overall potential for supporting computation in different forms. This paper is expected that it can show multimodal interface designers how to organize and integrate human input modalities while interacting with multimodal interfaces.

분자영상 획득을 위한 핵의학 영상기기 (Nuclear Medicine Imaging Instrumentations for Molecular Imaging)

  • 정용현;송태용;최용
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.131-139
    • /
    • 2004
  • Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging.

Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging

  • Cherry Kim;Wooil Kim;Sung-Joon Park;Young Hen Lee;Sung Ho Hwang;Hwan Seok Yong;Yu-Whan Oh;Eun-Young Kang;Ki Yeol Lee
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.838-850
    • /
    • 2020
  • Computed tomography (CT) is an important imaging modality in evaluating thoracic malignancies. The clinical utility of dual-energy spectral computed tomography (DESCT) has recently been realized. DESCT allows for virtual monoenergetic or monochromatic imaging, virtual non-contrast or unenhanced imaging, iodine concentration measurement, and effective atomic number (Zeff map). The application of information gained using this technique in the field of thoracic oncology is important, and therefore many studies have been conducted to explore the use of DESCT in the evaluation and management of thoracic malignancies. Here we summarize and review recent DESCT studies on clinical applications related to thoracic oncology.

차량편성구성에 따른 고속화물열차의 추진 및 제동성능 분석 연구 (A Study on the Propulsion and Braking Performance of the High Speed Freight Train with Composing the Rolling Stocks Formation)

  • 한성호
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.298-302
    • /
    • 2016
  • Currently, logistics are in small quantities and in diverse forms, and the amounts are continuously increasing. Railway logistics however are losing their market share every year mainly due to low operation speed and loading time, which means the trucks are covering the most of the freights. In order to solve these situations, this paper proposed the high speed freight train as working multi-modality with other modes to make effective transshipment. The high speed freight train has maximum operation speed of 300km/h and electric power to run centralized power supply. There are large dual door system, bogie system covering fluctuating load of 15[ton], automatic loading device, ULD(unit load device) bed and ULD locking system in this freight rolling stock. We calculated the performance of powering and braking capacity for this train and proposed how many vehicles are composed of train set. The results in this paper can help to make a decision to define the technical specification of High-speed freight train for the efficiency of rail freight service.

Gamma Camera Based FDG PET in Oncology

  • 박찬희
    • 대한핵의학회:학술대회논문집
    • /
    • 대한핵의학회 2002년도 춘계학술대회 및 총회
    • /
    • pp.45-53
    • /
    • 2002
  • Positron Emission Tomography(PET) was introduced as a research tool in the 1970s and it took about 20 years before PET became an useful clinical imaging modality. In the USA, insurance coverage for PET procedures in the 1990s was the turning point, I believe, for this progress. Initially PET was used in neurology but recently more than 80% of PET procedures are in oncological applications. I firmly believe, in the 21st century, one can not manage cancer patients properly without PET and PET is very important medical imaging modality in basic and clinical sciences. PET is grouped into 2 categories : conventional(c) and gamma camera $based_{(CB)}$ PET. $_{CB}PET$ is more readily available utilizing dual-head gamma cameras and commercially available FDG to many medical centers at low cost to patients. In fact there are more $_{CB}PET$ in operation than cPET in the USA. $_{CB}PET$ is inferior to cPET in its performance but clinical studies in oncology is feasible without expensive infrastructures such as staffing, rooms and equipments. At Ajou university Hospital, CBPET was installed in late 1997 for the first time in Korea as well as in Asia and the system has been used successfully and effectively in oncological applications. Ours was the fourth PET operation in Korea and I believe this may have been instrumental for other institutions got interested in clinical PET. The fellowing is a brief description of our clinical experience of FDG CBPET in oncology.

  • PDF

Multi-Modal Controller Usability for Smart TV Control

  • Yu, Jeongil;Kim, Seongmin;Choe, Jaeho;Jung, Eui S.
    • 대한인간공학회지
    • /
    • 제32권6호
    • /
    • pp.517-528
    • /
    • 2013
  • Objective: The objective of this study was to suggest a multi-modal controller type for Smart TV Control. Background: Recently, many issues regarding the Smart TV are arising due to the rising complexity of features in a Smart TV. One of the specific issues involves what type of controller must be utilized in order to perform regulated tasks. This study examines the ongoing trend of the controller. Method: The selected participants had experiences with the Smart TV and were 20 to 30 years of age. A pre-survey determined the first independent variable of five tasks(Live TV, Record, Share, Web, App Store). The second independent variable was the type of controllers(Conventional, Mouse, Voice-Based Remote Controllers). The dependent variables were preference, task completion time, and error rate. The experiment consist a series of three experiments. The first experiment utilized a uni-modal Controller for tasks; the second experiment utilized a dual-modal Controller, while the third experiment utilized a triple-modal Controller. Results: The first experiment revealed that the uni-modal Controller (Conventional, Voice Controller) showed the best results for the Live TV task. The second experiment revealed that the dual-modal Controller(Conventional-Voice, Conventional-Mouse combinations) showed the best results for the Share, Web, App Store tasks. The third experiment revealed that the triple-modal Controller among all the level had not effective compared with dual-modal Controller. Conclusion: In order to control simple tasks in a smart TV, our results showed that a uni-modal Controller was more effective than a dual-modal controller. However, the control of complex tasks was better suited to the dual-modal Controller. User preference for a controller differs according the Smart TV functions. For instance, there was a high user preference for the uni-Controller for simple functions while high user preference appeared for Dual-Controllers when the task was complex. Additionally, in accordance with task characteristics, there was a high user preference for the Voice Controller for channel and volume adjustment. Furthermore, there was a high user preference for the Conventional Controller for menu selection. In situations where the user had to input text, the Voice Controller had the highest preference among users while the Mouse Type, Voice Controller had the highest user preference for performing a search or selecting items on the menu. Application: The results of this study may be utilized in the design of a controller which can effectively carry out the various tasks of the Smart TV.

Utility of narrow-band imaging with or without dual focus magnification in neoplastic prediction of small colorectal polyps: a Vietnamese experience

  • Tien Manh Huynh;Quang Dinh Le;Nhan Quang Le;Huy Minh Le;Duc Trong Quach
    • Clinical Endoscopy
    • /
    • 제56권4호
    • /
    • pp.479-489
    • /
    • 2023
  • Background/Aims: Accurate neoplastic prediction can significantly decrease costs associated with pathology and unnecessary colorectal polypectomies. Narrow-band imaging (NBI) and dual-focus (DF) mode are promising emerging optical technologies for recognizing neoplastic features of colorectal polyps digitally. This study aimed to clarify the clinical usefulness of NBI with and without DF assistance in the neoplastic prediction of small colorectal polyps (<10 mm). Methods: This cross-sectional study included 530 small colorectal polyps from 343 consecutive patients who underwent colonoscopy at the University Medical Center from September 2020 to May 2021. Each polyp was endoscopically diagnosed in three successive steps using white-light endoscopy (WLE), NBI, and NBI-DF and retrieved for histopathological assessment. The diagnostic accuracy of each modality was evaluated with reference to histopathology. Results: There were 295 neoplastic polyps and 235 non-neoplastic polyps. The overall accuracies of WLE, WLE+NBI, and WLE+NBI+NBI-DF in the neoplastic prediction of colorectal polyps were 70.8%, 87.4%, and 90.8%, respectively (p<0.001). The accuracy of WLE+NBI+NBI-DF was significantly higher than that of WLE+NBI in the polyp size ≤5 mm subgroup (87.3% vs. 90.1%, p<0.001). Conclusions: NBI improved the real-time neoplastic prediction of small colorectal polyps. The DF mode was especially useful in polyps ≤5 mm in size.

Diagnosis of Graft Infection Using FDG PET-CT

  • Shim, Hun-Bo;Sung, Ki-Ick;Kim, Wook-Sung;Lee, Young-Tak;Park, Pyo-Won;Jeong, Dong-Seop
    • Journal of Chest Surgery
    • /
    • 제45권3호
    • /
    • pp.189-191
    • /
    • 2012
  • Graft infections after aortic replacement are a rare, but severe complication. Because surgical removal of the infection source is essential, an accurate diagnosis is required to prevent unnecessary treatment. Both of the patients described herein were diagnosed with graft infections using dual-modality positron emission tomography-computed tomography; one patient was a false-positive, and the other was confirmed with an infection.