• Title/Summary/Keyword: Dual chamber

Search Result 119, Processing Time 0.028 seconds

An Experimental Study on Semiconductor Process Chiller for Dual Channel (듀얼채널을 적용한 반도체공정용 칠러의 실험적 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.760-766
    • /
    • 2010
  • Excessive heat occurs during semiconductor manufacturing process. Thus, precise control of temperature is required to maintain constant chamber-temperature and also wafer-temperature in the chamber. Compared to an industrial chiller, semiconductor chiller's power consumption is very high due to its continuous operation for a year. Considering the high power consumption, it is necessary to develop an energy efficient chiller by optimizing operation control. Therefore, in this study, a semiconductor chiller is experimentally investigated to suggest energy-saving direction by conducting load change, temperature rise and fall and control precision experiments. The experimental study shows the cooling capacity of dual-channel chiller rises over 30% comparing to the conventional chiller. The time and power consumption in the temperature rising experiment are 43 minutes and 8.4 kWh, respectively. The control precision is the same as ${\pm}1^{\circ}C$ at $0^{\circ}C$ in any cases. However, it appears that the dual channel's control precision improves to ${\pm}0.5^{\circ}C$ when the setting temperature is over $30^{\circ}C$.

Frequency Range Expansion of Pneumatic Exciter by Using Dual-chamber (이중챔버를 이용한 공압가진기의 주파수 범위 확장)

  • Park, Young-Woo;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.909-919
    • /
    • 2013
  • Pneumatic exciters can be good replacements of electrodynamic, piezoelectric and hydraulic exciters owing to simple structure and large exciting force. One problem to be solved is a slow response caused by compressibility of air. Desirable frequency response characteristics of exciter are constant magnitude and zero degree phase, because users want no time delay between input signal and output force. For this reason, frequency range of pneumatic exciters is limited about 0~1 Hz. Therefore, expansion of frequency range is an important issue when designing the pneumatic exciter. In this paper, the pneumatic exciter which has same structure with active pneumatic isolator is dealt with. The dynamic characteristics are presented, and its limitation of expanding frequency range is shown based on analytical studies. Then the pneumatic exciter with dual-chamber is suggested to overcome this problem. Based on simulation study, a design method is presented.

An Efficient Transmissibility-design Technique for Pneumatic Vibration Isolator (지반진동절연을 위한 공압제진대의 전달률 설계기법)

  • Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.411-423
    • /
    • 2008
  • Pneumatic vibration isolator has a wide application for ground-vibration isolation of vibration-sensitive equipments. Recent advances In precision machine tools and instruments such as nano-technology or medical devices require a better isolation performance, which can be efficiently done by precise modeling- and design- of the isolation system. This paper will discuss an efficient transmissibility design method for pneumatic vibration isolator by employing the complex stiffness model of dual-chamber pneumatic spring developed in our previous research. Three design parameters of volume ratio between the two pneumatic chambers, the geometry of capillary tube connecting the two pneumatic chambers and finally the stiffness of diaphragm necessarily employed for prevention of air leakage were found to be important factors in transmissibility design. Based on design technique that maximizes damping of dual-chamber pneumatic spring, trade-off among the resonance frequency of transmissibility, peak transmissibility and transmissibility in high frequency range was found, which was not ever stated in previous researches. Furthermore this paper will discuss about negative role of diaphragm in transmissibility design. Then the design method proposed in this paper will be illustrated through experiment at measurements.

A Study on NOx Pollutant Reduction and Combustion Characteristics of Impinging-Jet-Flame combustion Process(III) (대향분출염 화염방식에 의한 NOx 생성저감과 연소특성 연구 (III))

  • 최성만;정인석;조경국
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.11-22
    • /
    • 1996
  • It has been generally accepted that NOx formation increases as the maximum temperature or correspondingly the maximum pressure of a combustion system increases. Recently some exceptional experimental results have been reportes that under certain circumstance NOx formation could be reduced while the maximum pressure was increasing by varying the methods of combustion for the same kind of premixed gases. Until now that kind of results have been acquired only for the case of a dual opposed prechamber. But the mechanism has not been clearly understood yet. 3D computer simulation has been tried to clarify the mechanism. Flor this purpose KIVA-Ⅱ has been modified and applied to the model combustion chamber with which the same kind of experimental works have been done by the authors. A good agreement with the experimental results was achieved with the spatial and temporal resolution which is hard th be obtained by the experimental methods. And it was observed that for the dual opposed prechamber case the time for the NOx formation, which is non-equilibrium reaction, is shorter than any other case by an appropriate mixing process in the main combustion chamber. The shorter time reduceed heat loss through the combustion chamber walls and thereby obtaines the higher maximum pressure.

  • PDF

Spatial Analysis of Turbulent Flow in Combustion Chamber using High Resolution Dual Color PIV (고분해능 이색 PIV를 이용한 가솔린 엔진 연소실내 난류의 공간적 해석)

  • Lee, K.H.;Lee, C.S.;Lee, H.G.;Chon, M.S.;Joo, Y.C.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.132-141
    • /
    • 1998
  • Particle image velocimetry(PIV), a planar measuring technique, is an efficient tool for studying the complicated flow field such as in-cylinder flow, and intake port flow. PIV can be also used for analyzing the integral length scale of turbulence, which is a measure of the size of the large eddies that contain most of the turbulence kinetic energy. In this study, dual color scanning PIV was designed and demonstrated by using a rotating mirror and a beam splitter. This PIV system allowed enlargement of flexibility in the intensity of vectors to be calculated by spatial filtering technique, even in combustion chamber with high velocity gradient and high vorticity$({\sim}1000s^{-1})$. A new color image processing algorithm was developed, which was used to find the direction of particle movement directly from the digital image. These measuring techniques were successfully applied to obtaining the turbulence intensity (~0.1m/s) and the turbulent integral length scale of vorticity(~1mm).

  • PDF

System Design for 20W Portable Fuel Cell (20W급 휴대용 연료전지 시스템 설계)

  • Jee, Young-Seok;Ko, Jeong-Sik;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.161-165
    • /
    • 2007
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells. In addition they can be built as a self/non-reformable system and single/dual chamber system. So We evaluated some types of SOFC theoretically, and compared the results from the fuel and performance efficiency point of view.

  • PDF

Successful Removal of 15-year-old Pacemaker Leads by Weight and pulley method

  • Kim, Hyun-Woo;Shin, Ho-Cheol;Jin, Han-Young;Seo, Jeong-Sook;Jang, Jae-Sik;Yang, Tae-Hyun;Kim, Dae-Kyeong;Kim, Dong-Soo
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.396-401
    • /
    • 2018
  • Extraction of old pacemaker leads remains a complex procedure owing to fibrotic encapsulation and lead adhesions. We report a case of extraction of 15-year-old pacemaker leads by weight and pulley method. A 81-year-old man presented with exposed pacemaker leads out of body with purulent discharge from a pacemaker insertion site. He inserted DDD (dual chamber pacing, dual chamber sensing dual function) pacemaker implantation 15 years ago for SSS. Previously pacemaker battery was removed 3 years ago due to recurrent infection of pacemaker scar site. We extracted the pacemaker leads by weight and pulley method successfully without any complications.

Development and Tree-Dimensional Kinematic Analysis of the Dual Chamber-based Drinking Aid for Stroke Patients: A Prospective Pilot Study (이중 체임버 구조가 내장된 뇌졸중 환자용 컵의 개발과 3차원 동작분석을 통한 운동 형상학적 유용성 검증: 전향적 예비연구)

  • Heo, Seo Yoon;Kim, Kyeong-Mi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.180-190
    • /
    • 2016
  • This prospective pilot clinical trial mainly focuses on developing dual chamber-based assistive cups which are suitable for stroke patients who have struggled with using there affected arms. It is unable to provide motor and sensory enhancement during drinking activities and to examine the feasibility of the devices for acute phase, even for chronic stroke survivors. The stroke patients(n=16; male=8, female=8), in this trial, were provided informed consent to the investigation. All the individuals participated in 1 weeks of training for using cups, randomized over dedicated dual chamber based assistive cups(DC) or placebo-cups(PC) training. All the participants were assessed within 1 week before and after the intervention period. 3-dimensional motion analysis, sEMG(surface electromyography) and 3-dimensional trunk movement were assessed. The result presents DC data group compared with PC showed, they needed lesser ROM(range of motion) at the phase of drinking in shoulder movements and lesser muscle activities on upper trapezius, deltoid middle fiber and triceps brachii muscles, lesser tilting movement on front and back side in drinking phase, the differences were statistically significant(p<.05). Dual chamber-based assistive cup could be one of efficient way to complete ADLs(activities of daily living), especially drinking tasks, and these evidence data may contribute to determine certain rehabilitation policies related to assistive devise usage.

ADP DRY ETCHER TECHNOLOGY (ADP Dry Etcher 장비개발의 현황)

  • Kim, Jeong-Tae
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2008.05a
    • /
    • pp.23-29
    • /
    • 2008
  • - High Density Plasma Source-CCP-Dual/Triple, RF Frequency Control - Radical/Flux Analysis - Low Pressure Process - Chamber Design (Process gap/Wall gap) - Chamber Temp. Control. - ESC Dielectric Materials - Uniform Gas Injection

  • PDF

Experimental study on the spray characteristics of a dual-manifold liquid-centered swirl coaxial injector

  • Lee, Ingyu;Yoon, Jungsoo;Park, Gujeong;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.4
    • /
    • pp.444-453
    • /
    • 2014
  • A throttleable rocket engine enables operational possibilities such as the docking of spacecraft, maneuvering in a certain orbit and landing on a planet's surface, altitude control, and entrance to atmosphere-less planets. Thus, throttling methods have long been researched. However, dual-manifold injectors, which represent one throttling method, have been investigated less than others. In this study, dual-manifold and single-manifold injectors were compared to determine the characteristics of dual-manifold injectors. Also, the effects of gas injection were investigated with various F/O ratios. To investigate the characteristics, mass flow rate, spray pattern, spray angle, and droplet size were measured. The spray angle and droplet size were captured by indirect photography. About 30 images were taken to assess the spray patterns and spray angle. Also, 700 images were analyzed to understand the droplet distribution and targeting area, moving to the right from the centerline with 1.11-cm intervals. The droplet size was obtained from an image processing procedure. From the results, the spray angle showed two transition regions, due to swirl momentum in the swirl chamber regardless of the F/O ratio. The droplet size showed similar trends in both dual-manifold and single-manifold injectors except in the low mass flow rate region. In the case of the dual- manifold injector, the spray cone was not fully developed in the low mass flow rate region due to low angular momentum in the swirl chamber.