• 제목/요약/키워드: Dry-Wall

검색결과 315건 처리시간 0.028초

건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구 (A Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger)

  • 김병조;최영기
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1018-1027
    • /
    • 2003
  • This study treats the analysis of the performance and the design of plume abatement wet/dry cooling tower with dry type heat exchanger using a numerical method. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parameter change simulations of the outer wall shape, the relative flowrate of air, and attachment of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of the cooling capacity and the additional cost are reduced and the plume is abated.

Pseudo-dynamic approach of seismic earth pressure behind cantilever retaining wall with inclined backfill surface

  • Giri, Debabrata
    • Geomechanics and Engineering
    • /
    • 제3권4호
    • /
    • pp.255-266
    • /
    • 2011
  • Knowledge of seismic earth pressure against rigid retaining wall is very important. Mononobe-Okabe method is commonly used, which considers pseudo-static approach. In this paper, the pseudo-dynamic method is used to compute the distribution of seismic earth pressure on a rigid cantilever retaining wall supporting dry cohesionless backfill. Planar rupture surface is considered in the analysis. Effect of various parameters like wall friction angle, soil friction angle, shear wave velocity, primary wave velocity, horizontal and vertical seismic accelerations on seismic earth pressure have been studied. Results are presented in terms of tabular and graphical non-dimensional form.

건식벽체 차음성능 분석 및 평가 (Analysis and evaluation of sound reduction performance of drywall system)

  • 백승경;장천상;고종철;이종인;김현배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.727-732
    • /
    • 2009
  • The objective of this study is to analyze and evaluate design factors relating to sound reduction performance in dry wall system. The main contents of this study are as follows. 1) Analysis and pre-evaluation of sound reduction performance of drywall system ; The sound reduction performance was pre-evaluated by INSUL simulation and these results of analyzing walls were analyzed by screening DOE(design of experiment) for selecting major factors that dominant influence the sound reduction performance. These main factors relating to sound reduction performance can be used for development of 1st grade sound reduction performance drywall system. 2) Design and evaluation of 1st grade sound reduction performance drywall system; The evaluation test of the sound reduction performance gave vaues higher than 1st grade (Rw+C=64). When campared with existing dry wall system, respectivelly, the new system shows performance higher than 8 dB.

  • PDF

The Feasibility Study on a High-Temperature Application of the Magnetostrictive Transducer Employing a Thin Fe-Co Alloy Patch

  • Heo, Tae-Hoon;Park, Jae-Ha;Ahn, Bong-Young;Cho, Seung-Hyun
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.278-286
    • /
    • 2011
  • The on-line monitoring for the wall thinning in secondary system has been considered one of main issues for the safety of nuclear power plants. To establish the on-line monitoring technique for the pipe wall thinning, the development of the ultrasonic transducer working in high-temperature is very important. In this investigation, the magnetostrictive transducer is concerned for high temperature condition up to $300^{\circ}C$. The magnetostrictive transducer has many advantages such as high working temperature, durability, cost-effectiveness, and shear waves, most of all. A thin Fe-Co alloy patch whose Curie temperature is over $900^{\circ}C$ was employed as a ferromagnetic material for magnetostriction. Wave transduction experiments in various temperature were carried out and the effect of bias magnets was considered together with the dry coupling performance of the transducer. From experimental results, consequently, it was found that the magnetostrictive transducer works stable even in high temperature up to $300^{\circ}C$ and can be a promising method for the on-line monitoring of the wall thinning in nuclear power plants.

다양한 곡률에 안정적인 등반 로봇을 위한 건식 점착물질의 실험기반 설계변수 최적화 (Optimization Design of Dry Adhesion for Wall-Climbing Robot on Various Curvatures Based on Experiment)

  • 유연형;신명석;서태원
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.398-402
    • /
    • 2014
  • This paper presents the results of a study on the optimal footpad design for vertical climbing on acrylic surfaces with various curvatures used Taguchi methods. For a climbing robot, the adhesion system plays an important role in the climbing process. Only an appropriate adhesion strength will prevent the robot from falling and allow it to climb normally. Therefore, the footpad is a significant parameter for a climbing robot and should be studied. Taguchi methods were used to obtain a robust optimal design, where the design variables were the flat tacky elastomeric shape, area, thickness, and foam thickness of the footpad. Experiments were conducted using acrylic surfaces with various curvatures. An optimized footpad was selected based on the results of the experiments and analysis, and the stability of the wall-climbing robot was verified.

열화상 카메라를 이용한 건식벽체의 스틸스터드 형상에 따른 열성능 비교연구 (A Study on Thermal performance as Form of Steel stud by Using Thermal Video Camera)

  • 장철용;엄은정;이나은
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.236-240
    • /
    • 2009
  • Dry wall using steel stud has the advantage of possibility to install various building, so it used to many buildings inside and outside of the country very rapidly. Though Light gauge steel framed housing offers many advantages to the consumer and the builder, the use of steel studs in wall system cause thermal problems such as thermal performance and pattern staing on walls. The present study has been conducted to observe effect of stud by the shape, and two kind of stud is made for this test to compare thermal performance. The test was conducted by setting those stud on the chamber and heating them. As the results of test and photograping by using TVS, there was temperature gap of each stud, and surface temperature of each section was appeared differently due to shape of stud delaying thermal bridge.

  • PDF

머리의 위치변화에 따른 파노라마방사선 사진상에서의 상악동 및 인접조직의 평가 (EVALUATION OF THE MAXILLARY SINUS AND ADJACENT STRUCTURES ON THE ORTHOPANTOMOGRAPH ACCORDING TO THE HEAD POSITIONS)

  • 이진경;김재덕
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.315-327
    • /
    • 1992
  • The purpose of this study was to evaluate the utilization of the orthopantomograph as a diagnostic aid to observe maxillary sinus and adjacent structures. For achieving this goal. the lead plates were attached to the five walls of the maxillary sinus of a human dry skull. The dry skull was placed in fourteen different positions; standard. 20mm forward. 20mm backward. 10 degree upward. 10 degree downward. 20mm lateral. forward & upward, forward & downward. forward & lateral. backward & upward. backward & downward, backward & lateral. upward & lateral. downward & lateral position. The obtained results were as follows: 1. The image of the medial wall was observed very differently according to the head positions. 2. The image of the anterior wall was observed at medial third to half of the maxillary sinus in each head position. 3. the image of the posterior wall was always observed at lateral third of the maxillary sinus in all head positions and more obviously in the downward-lateral position. 4. The image of the superior wall was observed at the inferior third to half of the orbit in each head position. 5. The image of the inferior wall was always observed at the inferior third of maxillary sinus in all head positions and observed more obviously in the standard and downward-lateral positions. 6. The images of the zygomatic process. zygomatic arch and zygomaticotemporal suture were observed very well in the downward-lateral position.

  • PDF