The Effect of Heat Sterilization on the Surface Topography and the Tensile Properties in Various Nickel Titanium Wires Including a Korean Product (열멸균과정이 nickel titanium호선의 기계적 성질과 표면상태에 미치는 영향)

  • Kim, Byoung-Ho;Nahm, Dong-Seok;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.927-935
    • /
    • 1998
  • The purpose of this study is to investigate the changes of mechanical properties and surface topography of various nickel titanium wires after heat sterilization for recycling with quantitative method. The materials used were four kinds of nickel titanium orthodontic wires including a Korean product. Experimental specimens were treated with two kinds of heat sterilization methods ; dry heat ($180^{\circ}C$, 60min) and autoclave ($121^{\circ}C$, 15-20psi, 30min). Mechanical properties were evaluated by tensile test with Instron 4466 (load cell capacity:.1000 kg, cross head speed:5mm/min, grip distince:40mm in room temperature). Surface topography of various wires was compared with each other qualitatively by using scanning electron microscopy and quantitatively by using profilometer. The findings were analyzed statistically with student t-tests. The results were as follows; 1. Neither method of heat sterilization had any effects on tensile properties of the nickel-titanium wires used in this experiment. 2. Before heat sterilization, the surface smoothness was highest in Optimalloy, followed by Align and Sentalloy, with NiTi showing the lowest smoothness value. 3. In surface topography, Align and Optimalloy were not influenced by heat sterilization. NiTi, on the other hand, had increased roughness after dry heat sterilization and Sentalloy showed the same tendency after each of the two heat sterilization procedures.

  • PDF

Effects of Sterilization for Quality Control and Content of baicalin in Scutellariae Radix (멸균법에 따른 황금의 미생물학적 품질보증과 바이칼린 함량에 미치는 영향)

  • Jeong, Choon-Sik
    • Korean Journal of Pharmacognosy
    • /
    • v.36 no.3 s.142
    • /
    • pp.220-223
    • /
    • 2005
  • The purposes of this study was to develop the best one among the methods using dry heat, gamma irradiation and alcohol gas, to sterilize Scutellariae Radix selected based on high frequency of circulation between merchants and high susceptibility to microbial contamination, through comparing these methods in terms of the followings; ⅰ) the efficacy of sterilization in comparison with cost, and ⅱ)the alteration of chemical components of these herbal medicines. The results of this study will be taken advantage of establishment of the maximum limit of microorganism contaminated in herbal medicines. From the results of this study we conclude the followings: ⅰ) The sterilizing method using dry heat may be inappropriate, because it seriously changed their color and morphology which is an essential criterion to estimate a measure of quality between merchants and consumers, although it effectively got rid of contaminated microorganism and did not alter major components, baicalin; ⅱ) The sterilizing method using gamma irradiation may be appropriate, because it showed a strong sterilizing effect, and no alteration of chemical components, color and morphology; ⅲ)The sterilizing method using alcohol gas may also be appropriate, because it had a similar effects as in the case of gamma irradiation. Collectively, we suggest that appropriate sterilizing methods to guarantee the microbial quality of this herbal medicine may be those using gamma irradiation and alcohol gas.

Mycelial growth of Lentinula edodes in response to different mixing time, pressure intensity, and substrate porosity

  • Chang, Hyun You;Seo, Geum Hui;Lee, Yong Kuk;Jeon, Sung Woo
    • Journal of Mushroom
    • /
    • v.15 no.4
    • /
    • pp.164-167
    • /
    • 2017
  • Biological efficiency (BE), the ratio of fresh mushrooms harvested per dry substrate weight, expressed as the percentage of Lentinula edodes, also known as shiitake, was determined using the 'Sanjo 701' strain stored in the Department of Mushroom at the Korea National College of Agriculture and Fisheries. The mycelia were grown in glass columns with varying levels of moisture content and varying mixing periods of 0.5, 1, 2, and 3 hours. The substrate was sterilized using a steam pressure autoclave sterilizer at normal and high pressure to avoid contamination. The results showed that mycelial growth (126 mm/15 days) was optimized at 55% moisture content. The best mycelial growth of 117 mm/15 days was obtained with 2 hours of mixing time. Normal pressure sterilization yielded better results with mycelial growth of 96 mm/15 days at $100^{\circ}C$ compared to 88 mm /15 days with sterilization at $121^{\circ}C$. Mycelial density was higher, i.e. 3(+++), with normal pressure sterilization compared to 2(++) with high pressure sterilization. Furthermore, sawdust mixed with 5% woodchips increased the substrate porosity and yielded higher mycelial growth. Thus, we demonstrated that the optimum harvest or potential increased yield of shiitake can be obtained by modulating moisture content, mixing time, and substrate porosity.

Quality Characteristics and Functionality of Low Alcohol Wines after Heat Sterilization and Non-Thermal Sterilization (저알코올 와인의 가열 및 비가열 살균 후 품질 특성 및 기능성)

  • Shin, Hyerim;Park, Hyejin;Hwang, On Bit;Choi, Sungyeol;Park, Eui Kwang;Yoon, Dong Kyu;Yoon, Hyang-Sik
    • The Korean Journal of Food And Nutrition
    • /
    • v.35 no.5
    • /
    • pp.343-352
    • /
    • 2022
  • Low alcohol (6%) wines were manufactured using Campbell Early. To develop the sterilization process of low alcohol wines, red wines were heat sterilized, and rose wines were nonthermal sterilized by concentration using potassium metasulfite and potassium sorbate. Samples were stored at 25℃ and quality characteristics were investigated by period. Results of this study revealed the pH of the samples after sterilization ranged from 3.15 to 3.19, and the total acidity of wines ranged from 0.011 to 0.024%. The free SO2 contents of wines ranged from 13.00 to 29.678 mg/L, and the total SO2 contents of wines ranged from 47.50 to 121.00 mg/L. L (lightness) of wines decreased whereas a (redness) and b(yellowness) increased. The hue value of wines ranged from 0.52 to 1.03, and decreased significantly(not including rose sweet wines). The color intensity of red and rose dry wines after sterilization increased, whereas red and rose sweet wines decreased. The DPPH radical scavenging activity of red wines and rose wines ranged between 75.50 to 89.23%, and 36.60 to 56.54%, respectively. The total polyphenol contents were 57.51~182.63 mg%. Results of this study provide scientific information to establish the sterilization process of low alcohol wines.

Evaluation of Nonthermal Plasma Treatment by Measurement of Stored Citrus Properties

  • Seo, Youngwook;Park, Jong-Ryul;Park, Hoe Man
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.401-409
    • /
    • 2018
  • Decay of fruit is one of the greatest issues in fruit storage. Purpose: In this study, citrus sterilization was performed to evaluate a dry sterilization method using an atmospheric-pressure nonthermal plasma treatment based on a dielectric-barrier discharge technique. Methods: Citrus samples were stored under four different environmental conditions as follows: group A had cold storage with plasma treatment with a temperature of $6.2{\pm}1.0^{\circ}C$ and relative humidity (RH) of $93.4{\pm}8.2%$, group B had ambient-temperature storage with $22.9{\pm}2.3^{\circ}C$ and $82.1{\pm}4.5%$ RH, group C ambient-temperature storage with plasma treatment with $25.3{\pm}2.2^{\circ}C$ and $90.0{\pm}2.8%$ RH, and group D had cold storage with $5.7{\pm}1.0^{\circ}C$ and $93.4{\pm}6.5%$ RH. Results: As a result of citrus surface sterilization by plasma treatment, treatment groups A and C together showed an average of 16.1 CFU/mL of mold colonies, while control groups B and D showed an average of $2.2{\times}10^2CFU/mL$ or approximately 13 times greater than the treatment groups. Regarding the mean concentration of aerobic bacteria colonies, the treatment groups (A and C) and control groups (B and D) showed an average of 7.1 CFU/mL and $1.9{\times}10^3CFU/mL$, respectively. This is approximately a 270-fold difference in the concentration of pathogen colonies between treatment and control groups. Conclusions: The results showed the potential of nonthermal plasma treatment for citrus storage in enhancing storage duration and quality preservation.

Effects of Sterilization for Quality Control on the Content of Paeonol in Moutan Radicies Bark (품질 보증을 위한 멸균법이 목단피의 패오놀 함량에 미치는 영향)

  • Lee, Yong-Soo;Shin, Woon-Seob;Cho, So-Yean;Ze, Keum-Ryon;Lee, Hyo-Min;Jeong, Choon-Sik
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.180-184
    • /
    • 2005
  • The purpose of this study was to develop the best methods to sterilize Moutan Root Bark which is frequently used as a herbal medicine, and known to have high susceptibility to m icrobial contamination. We used dry heat, gamma irradiation and alcohol gas treatment for sterilization, and evaluated these methods in terms of the followings; I) the efficacy of sterilization, and ii) the chemical alteration of a major component of the harbal medicines. Treatment with dry heat effectively got rid of contaminated microorganisms, and did not significantly alter the content of paeonol. However it seriously changed the color and morphology which are an essential criterion to estimate a measure of quality of medicinal herbs. Treatment with gamma irradiation showed a strong sterilizing effect, and no alteration of the content of paeonol, color and morphology. Alcohol gas treatment resulted in similar effects as those in gamma irradiation. Collectively, these results suggest that appropriate sterilizing methods to guarantee the microbial quality of this herbal medicine may be those using gamma irradiation or alcohol gas.

Effects of Sterilizing Methods on the Content of Index .Constituents of Herbal Medicines (품질 보증을 위한 멸균법이 수종 생약의 지표성분 함량에 미치는 영향)

  • Jeong, Choon-Sik;Cho, So-Yean;Lee, Yong-Soo
    • YAKHAK HOEJI
    • /
    • v.50 no.6
    • /
    • pp.415-420
    • /
    • 2006
  • The purpose of this study was to develop the best methods to sterilize herbal medicines which is frequently used and known to have high susceptibility to microbial contamination. We used dry heat, gamma irradiation and alcohol gas treatment for sterilization, and evaluated these methods in terms of the followings; i) the efficacy of sterilization, and ii) the chemical alteration of index constituents of herbal medicines. Treatment with dry heat effectively eliminated the contaminated microorganisms, and did not significantly alter the content of berberine chloride, paeoniflorin and amygdalin in Phellodendron Bark, Peony Root and Apricot Kernel, respectively: However it seriously changed the color and morphology which are essential criteria to estimate a measure of quality of herbal medicines. Treatment with gamma irradiation showed a strong sterilizing effect, and no alteration of the content of index constituents, color and morphology: Alcohol gas treatment resulted in similar effects as those in gamma irradiation. Collectively; these results suggest that treatment with gamma irradiation or alcohol gas may be useful methods for sterilizing herbal medicines without a decrease in their microbial quality.

Establishment of some Conditions for the Development of Legume Inoculant (근류균 접종제 개발을 위한 우수 증량제의 선발 및 생산 최적조건)

  • Kim, Chang-Jin;Rhee, Yoon;Yoo, Ick-Dong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.23 no.2
    • /
    • pp.146-151
    • /
    • 1990
  • The viability of rhizobia according to various kinds of carrier materials, inoculum size, storage temperature and sterilization methods was investigated for the development of legume inoculat. The results were followings. 1. Peat and perlite were favorable as a carrier material. 2. Rhizobia counts were reached to $5{\times}10^8cells/g$ carrier 1-2 weeks after inoculation with inoculum size below $10^4cells/g$ carrier. 3. $10^9cells/g$ carrier was maintained 12 weeks after storage at room temperature. 4. Steam heat sterilization was the best method for carrier sterilization among methods used in this study. Dry heat and ${\gamma}$-ray sterilization were also applicable.

  • PDF

A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability (임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구)

  • Won, Ho-Yeon;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-52
    • /
    • 2008
  • Purpose: Resonance Frequency Analysis(RFA) technique can be used as an effective method in measuring the implant stability and documenting the clinical results. This technique also determines how stable the implant is before performing a prosthetic practice. Having become one the guidelines of the implant therapy whose final objective is the immediate loading, the $Osstell^{TM}$ mentor is giving a lot of information to the clinicians recently. In this communication, experiments were performed to investigate how reliable the measured ISQ values by $Osstell^{TM}$ mentor are, and to see if those are also stable even after sterilization. As five objectives: 1) How stable measured ISQ values after fixation $Smartpeg^{TM}s$ for 400 times. 2) How stable measured ISQ values after 'attach-detach'$Smartpeg^{TM}'s$ for 400 times. 3) How stable measured ISQ values after clinical sterilization methods. 4) How stable measured ISQ values after repeatedly sterilization in autoclave for 10 times. 5) What is the critical temperature which is lost the magnetism of $Smartpeg^{TM}$. Materials and Methods: Clinical sterilization methods(Autoclave sterilization, Dentistar sterilization, Ultra violet sterilization, Vacuum dry unit sterilization, Boiling water sterilization, combined $H_{2}O_{2}$ and Alcohol sterilization).$Smartpeg^{TM}s$. D3 Block bone($3{\times}9{\times}2cm$). Osstem implant(${\emptyset}4.1$-10mm).$Osstell^{TM}$ mentor. Individual experiment was used 8 number of $Smartpeg^{TM}s$ and they had measured to ISQ values of before experiment and after experiment. Results: 1. The measured ISQ values did not change after fixation $Smartpeg^{TM}s$ for 400 times. 2. There was no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ for 400 times. 3. The measured ISQ values did not change after the usual clinical sterilization methods. 4. The measured ISQ values did not change after sterilization in autoclave for 10 times. 5. It was impossible to exactly measure the critical temperature which is lost the magnetism of $Smartpeg^{TM}s$. But, the results was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10 minute. Conclusion: The measured ISQ values showed insignificant differences in case of no changes in the magnetism of the $Smartpeg^{TM}s$. It seems that the $Smartpeg^{TM}s$ can be used repeatedly in every measurement if the original magnetisms of the $Smartpeg^{TM}s$ can be recognized. There seems to be no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ only if the screw pitches were unimpaired. The clinical sterilization methods seems acceptable because the result was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10minute.

Convergence Study on Sterilized Dental Instruments Expiration Date (멸균된 치과기구의 유효기간에 관한 융합연구)

  • Na, Jae-Gyeong;Park, Hae-Ryeon;Sung, Hye-Lin;Song, In-Ha;Joo, Jung-Hwan;Kang, Kyung-hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.129-135
    • /
    • 2018
  • This study aimed to investigate the contamination rate of microorganisms by times after sterilization in mirrors, dental explorers, and pincettes which are the basic tools used in the dental clinic. 60 samples by each tool were used upon packaging them by 10 units. Contamination rate of microorganisms were tested using dry film media(3M Petrifilm Plates) which is a quick check upon collecting 10 samples right after sterilization, at Week 2, 3, 4, 5, and 6. At Week 0 when was right after sterilization, no microorganism was detected in any tools while they were detected in 2 mirrors, 2 dental explorers, and 2 pincettes at Week 6. 2 to 4 colonies on average were detected in mirrors at Week 2 and 4, 1 to 2 colonies in explorers from Week 5, and no colony was found in pincettes until Week 5 but 1 to 2 colonies at Week 6. Based on these results, the needs of effective periods are suggested for the sterilized tools together with their safe usages.