• Title/Summary/Keyword: Dry Floor System

Search Result 52, Processing Time 0.023 seconds

A Study on the Dry-Shrinkage Properties For Floor Mortar With Crack-Reducing (균열저감형 바닥마감전용 모르터의 건조수축특성 연구)

  • 이종렬;이웅종;채재홍;박경상;김기수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.175-180
    • /
    • 1999
  • The heating system of korea apartment house is called Ondol. The surface finishing mortar of this floor system typically used the cement based mortar, where the surface finishing mortar easily appears the crack. To order to crack control, the cement that added expansive additive used to reducing dry-shrinkage. For the surface finishing mortar, the types of shrinkage is known as plastic shrinkage, dry-shrinkage and autogenous This experimental study is to investigate the difference on dry-shrinkage of the cement that added expansive additives and OPC. The test method is varied the ration of water/cement (W/C) and the ratio of sand/cement(S/C). For OPC, The increase of the ratio of S/C is reduced dry-shirnkage but for the cement that added expansive additives, the increase of the ratio of S/C is augmented dry-shrinkage For OPC, The increase of the ratio of W/C is augmented dry-shrinkage but for the cement that added expensive, the increased of the ratio of W/C is reduced dry-shrinkage.

  • PDF

Remotely Operated Decontamination Systems for Use in DFDF

  • Kim, Kiho;Park, Jangjin;Myungseung Yang
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.438-446
    • /
    • 2003
  • This paper presents the development of the remotely operated decontamination systems for use in a highly radioactive zone of the DUPIC Fuel Development facility of the Irradiated Material Examination Facility at the Korea Atomic Energy Research Institute. The remotely operated decontamination systems were designed to completely eliminate human interaction with hazardous radioactive contaminants. These decontamination systems are mainly classified into three systems depending on the task environment - a fabrication equipment decontamination system, a hot-cell floor decontamination system, and an isolation room floor decontamination system. A decontamination system for contaminated fabrication equipment utilizes dry ice pellet blasting method to decontaminate contaminated surface of the equipment. The decontamination systems for the hot-cell floor and isolation room floor employ a vacuum cleaning method to decontaminate the contaminated floor and collect loose dry spent nuclear fuel debris and other radioactive waste placed on the floor. The human operator from the out-of-cell performs a series of decontamination tasks remotely by manipulating decontamination systems located in-cell via a handcontroller with the aid of vision feedback information. The environmental, functional and mechanical design considerations, control system and capabilities of the remotely operated decontamination systems at a high radioactive environment are also described.

  • PDF

Quality of Dry Cement Mortar for Floor Heating Depending on Water-to-Dry Mortar Rutio (난방을 위한 바닥용 건조 시멘트 모르타르의 혼합수량비 변화에 따른 품질 특성)

  • Park, Sang-Jun;Hwang, Yin-Seong;Lee, Gun-Cheol;Kim, Jong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.181-188
    • /
    • 2021
  • In this study, the various performance of dry cement mortar for Korean floor heating system depending on water-to-dry mortar ratios (W/DM) applied in project site was evaluated. According to the experiment conducted, the importance of mixing water for dry cement mortar was revealed by resultant performance or quality of the dry cement mortar for floor finishing by changing W/DM controlled in project site by workers. As the general trend, the flow was increased, and the unit volume weight was decreased with increasing W/DM. Additionally, compressive strength and drying shrinkage were significantly influenced by W/DM. Hence, it can be stated that the adding water for dry cement mortar should be managed precisely since excessively increased W/DM for workability improvement can cause performance degradation of floor mortar with the failures such as excessive bleeding, and severe segregation during the fresh state. As a summary of the study, to achieve a desirable performance of dry cement mortar, approximately 20 % of W/DM can be suggested to be managed in project site.

A Study on Design of Dry Floor Tile Unit Method System (바닥타일 건식공법용 수지매트 개발에 관한 연구)

  • 김상미;조상영;김성식;임남기;정병훈;김무성
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.22-27
    • /
    • 2001
  • The purpose of this study is development of dry floor tile method that practically used for improving wet method's defect, with resin mat design. PE resin used mat which satisfied with bonding test, waterproof test, resistance to chemical attack test, resistance to impact test and freezing and thawing test is confirmed the basic property.

  • PDF

Behavior Characteristics of PCM Infilled Floor System at Elevated Temperature (고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성)

  • Park, Min-Jae;Min, Jeong-Ki;Yoon, Sung-Won;Ju, Young K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it.

A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe (강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구)

  • Kim, Chang-Hee;Kim, Jong-Su;Woo, Jae-Ho;Kong, Sang-Wun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

The Study on the Dry Floor Tile Unit System used Resin Mat (수지매트를 이용한 바닥타일 건식공법 시스템에 관한 연구)

  • 김성식;임남기;정병훈;정재영;정상진
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.185-190
    • /
    • 2001
  • The purpose of this study is the development of practical Dry floor tile unit method that settle the defect of a wet method and designed for resin mat. With use of PE resin which is confirmed the basic property, it is developed that resin mat, joint-sealing compound with fixed form and space management to Dry floor tile unit method. The result of this study is below. 1) To acquire above the 4kgf/$\textrm{cm}^2$ - construction specification criterion, the bonding space that between resin mat and tile has to occupy the 50% of resin mat module space(10,000$\textrm{cm}^2$). 2) Criteria of bonding part plane is below. simpleness of metal form. productivity, uniform quality after injection molding cooling, easy cutting for remain space management, adhesive property, construction ability, transformation of a severed piece under pressure and so on. 3) To get the shape that could protect the interfacial breakdown, it is designed that resin mat and tile are unified after the bond input. 4) Adapted joint-sealing compound is the material of urethane kinds wedge form. Resin mat has the water passageway that could drain the water. 5) To manage the severed piece of tile, the resin mat is likely to divide the half and the quarter and the plastic drainage is developed in the severed piece.

  • PDF