• Title/Summary/Keyword: Droplet Measurement

Search Result 147, Processing Time 0.02 seconds

An Experimental Study on The Effect of Ultrasonic Atomization in Agricultural Twin-fluid Nozzle (농업용 액체 분무용 초음파 분사효과에 관한 실험적 연구)

  • Chung, J.D.;Lim, Y.J.
    • Journal of ILASS-Korea
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2003
  • The objective of this study is to investigate experimentally atomization characteristics for differently made an ultrasonic twin-fluid nozzle. A spray system, an ultrasonic system, and three different type(Nozzle type, Tube type, Conventional type)are made and tested by applied with ultrasonic energy. In this investigation, the measurement and calculation of spray droplet are to analyze the effects of ultrasonic energy on the agricultural atomization system. Through the measurement of suray angle, spray column using, high speed camera and PDA, it is found that nozzle type is highest efficiency than that of tube type and conventional type. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 9% respectively and spray angle was wide spray.

  • PDF

Hexane Vapor Concentration Measurement of a Liquid Jet in Crossflow (수직분사제트에서의 헥산 증기농도측정)

  • Oh, Jeong-Seog;Lee, Won-Nam;Lee, Jong-Geun;Santavicca, Dominique A.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.383-389
    • /
    • 2010
  • The vapor concentration of hexane in a liquid spray jet in crossflow was qualitatively measured on the basis of the infrared (IR) extinction techniques. The objectives of the present study are to understand the whole evaporation process from droplet breakup to vapor and to confirm the usefulness of IR emission method in a lab-scale ramjet combustor. From the experimental results, we concluded that hexane vapor mole fraction increased with temperature rise and kept nearly constant during the variation of fuel to air momentum ratio.

  • PDF

A Study on the Spray Characteristics of Small LRE Injector through PIV and PDA Measurements (PIV 및 PDA 계측에 의한 소형 액체로켓엔진 인젝터의 분무특성 연구)

  • Kim, Jin-Seok;Jung, Hun;Kim, Jeong-Soo;Park, Jeong;Kim, Sung-Cho;Choi, Jong-Wook;Jang, Ki-Won
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.63-67
    • /
    • 2006
  • Spray characteristics of an injector employed in mono-propellant hydrazine thrusters were investigated by PIV(particle image velocimetry) and PDA(phase Doppler anemometry) techniques. The instantaneous plane images captured by PIV measurement were examined in order to judge the pass-fail criteria of spray injection performance according to the specific pressure supplied. PDA technique was also applied to measure the velocity and droplet size of spray which were not obtainable by PIV measurement. The objective of this experimental study is the evaluation of the injector performance which may be utilized for the design of brand-new injector through the clear understanding of spray characteristics.

  • PDF

Hexane Vapor Concentration Measurement of a Liquid Jet in Crossflow (수직분사제트에서의 헥산 증기농도측정)

  • Oh, Jeong-Seog;Lee, Won-Nam;Lee, Jong-Geun;Santavicca, Dominique A.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.25-31
    • /
    • 2010
  • The vapor concentration of hexane in a liquid spray jet in crossflow was qualitatively measured on the basis of the infrared (IR) extinction techniques. The objectives of the present study are to understand the whole evaporation process from droplet breakup to vapor and to confirm the usefulness of IR emission method in a lab-scale ramjet combustor. From the experimental results, we concluded that hexane vapor mole fraction increased with temperature rise and kept nearly constant during the variation of fuel to air momentum ratio.

Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness - (스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 -)

  • 김재옥;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber (반건식 세정기의 산성가스 제거성능에 관한 실험적 연구)

  • Yang, Hyun-Mo;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.589-598
    • /
    • 2000
  • A pilot-scale Spray Drying Sorber (SDS) system was set up to evaluate the effect of spray characteristics on the desulfurization yield. The size distribution and the Sauter Mean Diameters of slurry droplets were measured in advance using the optical size measurement system, Malvern 2600. The desulfurization yield of the drying chamber by size was measured for the conditions of inlet gas and spray injection. As a reagent, 10% limestone slurry of $Ca(OH)_2$ was treated with flue gas containing $SO_2$, and the combustion gas analyzer and gas detectors were attached to measure the $SO_2$ concentration. With a flow rate of 144 Nm3/h and a temperature range of $200{\sim}300^{\circ}C$, the experiments were performed for the Stoichiometric Ratio (SR) of 1.0 to 3.0 and droplet mean diameter of 6.5 to $34.3{\mu}m$. In case of smaller spray droplets, the desulfurization efficiency improved due to the increase of total droplet surface area, while the reduction in evaporation time reduced the contact time between the droplets and $SO_2$ gas. In some typical region of droplet diameter, this negative effect, reduction of contact time, became dominant and the desulfurization yield decreases the desulfurization yield in spite of the expansion in absorption area. These results revealed that there exists the optimal size of spray droplets for a given state, which is determined by the compromise between the total surface area of slurry droplets and the evaporation time of droplets. The measurements also indicated that the inlet temperature of flue gas changes the optimal injection condition by varying the driving force for evaporation. The results confirm that the effect of the evaporation time of slurry droplets should be considered in analyzing the desulfurization yield as well as the total surface area, for it is a significant aspect of the correlation with the capabilities of $SO_2$ absorption in wet droplets. In conclusion, the optimal condition of spray can be determined based on these results, which might be applied to design or scale-up of SDS system.

Precise Static Contact Angle Measurements Using Pythagolas Rule (피타고라스 원리를 이용한 정적 접촉각 정밀 각도 측정방법)

  • Choi, Jin-Yeong;Kwon, Dong-Jun;Wang, Zuo-Jia;Shin, Pyeong-Su;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.15 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • Pythagolas rule was used for investigation of static contact angle in particular figures. Static contact angle measurement was important to evaluate the wettability between solid and liquid. Optimum measurement method and standardization of calculation for static contact angle were investigated for practical application. Optimum diameter of droplet for static contact angle measurement was confirmed as 1 mm. Contact angle measurement using Pythagolas rule was also used to calculate advancing, receding angle and wettability of different surface condition. At last, it was concluded that the Pythagolas rule method was more accurate than general lineation method for static contact angle measurement.

Spray Pattern Analysis of the Injector in a Small Liquid-Rocket Engine (소형 액체로켓엔진 인젝터의 분무패턴 분석)

  • Jung, Hun;Kim, Jin-Seok;Kim, Jeong-Soo;Park, Jeong;Kim, Sung-Cho;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.146-149
    • /
    • 2006
  • Spray characteristics of an injector employed in mono-propellant hydrazine thrusters were investigated by PIV(particle image velocimetry) and LDA/PDA(laser/phase Doppler anemometry) techniques. The instanteneous plane image data captured by PIV measurement were examined in order to judge a pass-fail criteria of spray injection performance according to the specific pressure supplied. LDA/PDA technique were also applied to measure the velocity and droplet size of spray were not obtained from PIV measurement. The objective of this experimental study was the clear understanding of spray characteristics as well as the derivation of injector performance to understand clearly the spray characteristics by comparing the both results.

  • PDF

Study on the Atomization Characteristics of a Counter-swirling Two-phase Atomizer with Variations of Swirl angle (역선회 이류체 미립화기의 선회각 변화에 따른 미립화 특성연구)

  • Kim, N.H.;Lee, S.G.;Ha, M.H.;Rho, B.J.;Kang, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.125-130
    • /
    • 2001
  • Experimental and analytical researches have been conducted on the twin-fluid atomizers for better droplet breakup during the past decades. But, the studies on the disintegration mechanism still present a great challenge to understand the drop behavior and breakup structure. In an effort to describe the aerodynamic behavior of the sprays issuing from the internal mixing counter-swirling nozzle, the spatial distribution of axial (U) radial (V) and tangential (W) components of droplet velocities are investigated across the radial distance at several axial locations of Z=30, 50, 80, 120 and 170mm, respectively. Experiments were conducted for the liquid flow rates which was kept constant at 7.95 g/s and the air injection pressures were varied from 20 kPa to 140 kPa. Counter-swirling internal mixing nozzles manufactured at angles of $15^{\circ},\;30^{\circ},\;45^{\circ}$ and $60^{\circ}$ the central axis with axi-symmetric tangential-drilled holes was considered. The distributions of velocities and turbulence intensities are comparatively analyzed. PDPA is installed to specify spray flows, which have been conducted along the axial downstream distance from the nozzle exit. Ten thousand of sampling data was collected at each point with time limits of 30 second. 3-D automatic traversing system is used to control the exact measurement. It is observed that the sprays with all swirl angle have the maximum SMD for on air injection pressure of 20 kPa and 140 kPa with centerline, respectively. The nozzle with swirl angle of $60^{\circ}$ has vest performance.

  • PDF

Measurement of Size Distributions of Submicron Electrosprays Using a Freezing Method and an Image Processing Technique (냉각법 및 영상 처리기법을 이용한 서브마이크론 정전분무 액적의 크기분포 측정)

  • Gu, Bon-Gi;Kim, Sang-Su;Kim, Yu-Dong;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1400-1407
    • /
    • 2001
  • The size distributions of electrospray droplets from the Taylor cone in cone-jet mode are directly measured by using a freezing method and a transmission electron microscope (TEM) image processing technique. These results are compared with the data obtained by an aerodynamic size spectrometer (TSI Aerosizer DSP). The use of glycerol seeded with NaI and a freezing method make it possible to sample droplets with their original sizes preserved. Since pictures of droplets are taken with TEM with very low vapor pressure of the solution, evaporation is suppressed by freezing. For liquid flow rates below 1 nl/sec, the measured droplet diameters by the TEM image processing technique and the aerosizer are in the range of 0.25 to 0.32 m add 0.3B to 0.40m, respectively. Comparing the TEM data with the aerosizer measurements, it has been revealed that the TEM image processing technique can afford more accurate values of droplet size distributions in the submicron range of 0.1 to 0.4m.