• 제목/요약/키워드: Droplet Cluster

검색결과 7건 처리시간 0.027초

초음파를 이용한 부상유적군의 연소기구에 관한 기초연구 (An Elementary Study on the Combustion Mechanism of Levitated Droplet Clusters by Ultrasonic Wave)

  • 정진도;김승모
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1191-1199
    • /
    • 2003
  • This paper describes to observe the combustion process of only one droplet cluster. In this study, liquid fuel was atomized by ultrasonic wave to form an acoustically levitated droplet cluster. In order to elucidate the detailed structure of burning process of the droplet cluster, laser tomography method was applied. Time-series planar images of fuel droplets were processed and diameter of the each droplet was calculated based on the Mie-scattering theory. Using these data, the modified droplet group combustion number was estimated in time-series. As the result, when the internal droplet group combustion occur, the modified group combustion number dose not decrease monotonically, but show a tow-staged decreasing process. In all case of combustion process, combustion reactions were measured two types that combustion speed was fast and slow. It was casued by difference of concentration degree and droplet size distribution.

동시 시계열 계측에 의한 예혼합 분무화염 내 유적군 연소기구의 평가 (Evaluation of Combustion Mechanism of Droplet Cluster in Premixed Spray Flame by Simultaneous Time-Series Measurement)

  • 황승민
    • 대한환경공학회지
    • /
    • 제31권6호
    • /
    • pp.442-448
    • /
    • 2009
  • 예혼합 분무화염의 유적군 연소 기구를 평가하기 위하여 레이저 가시화법, MICRO (multi-color integrated Cassegrain receiving optics) 및 PDA (phase Doppler anemometer) 광학계측 시스템을 이용하여 동시 시계열 계측을 실시하였다. 또한 유적군의 군연소수를 실험적으로 산출하여 이론해석에 적용하였을 경우 실제로 관찰되는 군연소 형태와 일치하는지에 대하여 검토하였다. 유적군 단면화상에 의해 확인된 모든 유적군에 대하여 실험적으로 군연소수 $G_c$를 산출한 결과 주로 내부 군연소와 외부 군연소로 분류되었으며 이론해석과 일치하였다. 또한 실제 관찰된 군연소 형태와 그 유적군의 군연소수를 이론해석에 적용한 경우에 군연소 형태가 일치하는 경우와 일치하지 않는 경우가 있었다. 일치하지 않는 원인은 군연소수를 유적의 기하학적 배치만으로 결정한 것이나 현상의 3차원성이 측정 결과에 영향을 미친 것이라고 생각되어진다.

예혼합 분무화염내의 이중적 액적 연소속도에 관한 관찰 (Observation on Double-droplet Combustion Speed in Premixed Spray Flame)

  • 이치우;심한섭
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.119-126
    • /
    • 2004
  • In order to elucidate the modes of double-droplet combustion speed in premixed spray flame, the difference between flame propagation speed and droplet cluster disappearance speed are experimentally investigated using a premixed spray burner system, It was confirmed that flame speed concerned with premixed-mode combustion in the spray flame was approximately 2.0 m/s in average while mean disappearance speed of droplet clusters, which were dominated by diffusion-mode combustion in downstream of the flame, was evaluated as much as 0.45 m/s. It was clarified that both characteristics of premixed-mode and diffusion-mode combustion in spray flames are of much difference in nature, even though both speed, which are supposed to depend on local properties of the spray itself and flow conditions surrounding droplet clusters, are scattered in experiments.

Generation of Water Droplet Ion Beam for ToF-SIMS Analysis

  • Myoung Choul Choi;Ji Young Baek;Aram Hong;Jae Yeong Eo;Chang Min Choi
    • Mass Spectrometry Letters
    • /
    • 제14권4호
    • /
    • pp.147-152
    • /
    • 2023
  • The increasing demand for two-dimensional imaging analysis using optical or electronic microscopic techniques has led to an increase in the use of simple one-dimensional and two-dimensional mass spectrometry imaging. Among these imaging methods, secondary-ion mass spectrometry (SIMS) has the best spatial resolution using a primary ion beam with a relatively insignificant beam diameter. Until recently, SIMS, which uses high-energy primary ion beams, has not been used to analyze molecules. However, owing to the development of cluster ion beams, it has been actively used to analyze various organic molecules from the surface. Researchers and commercial SIMS companies are developing cluster ion beams to analyze biological samples, including amino acids, peptides, and proteins. In this study, a water droplet ion beam for surface analysis was realized. Water droplets ions were generated via electrospraying in a vacuum without desolvation. The generated ions were accelerated at an energy of 10 keV and collided with the target sample, and secondary ion mass spectra were obtained for the generated ions using ToF-SIMS. Thus, the proposed water droplet ion-beam device showed potential applicability as a primary ion beam in SIMS.

Vapor Bubble Nucleation : A Microscopic Phenomenon

  • Kwak, Ho-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1271-1287
    • /
    • 2004
  • In this article, vapor bubble nucleation in liquid and the evaporation process of a liquid droplet at its superheat limit were discussed from the viewpoint of molecular clustering (molecular cluster model for bubble nucleation). For the vapor bubble formation, the energy barrier against bubble nucleation was estimated by the molecular interaction due to the London dispersion force. Bubble nucleation by quantum tunneling in liquid helium under negative pressure near the absolute zero temperature and bubble nucleation on cavity free micro heaters were also presented as the homogenous nucleation processes.

Study of Nano-scale Fullerene (C60) Clusters Formed in Micro-sized Droplet by UV Irradiation

  • Yeo, Seung-Jun;Ahn, Jeung-Sun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.571-571
    • /
    • 2012
  • We discovered the formation of C60 aggregates in solution by means of photoluminescence spectroscopic study on C60 in solutions. From the in-depth investigation of temperature dependence of the luminescence of C60 in toluene, benzene and CS2 solutions, we reported that the C60 aggregates are formed during cooling at the freezing temperature of these solvents. Furthermore, the C60 aggregates can be changed to stable structures by irradiating with UV pulse-laser (Nd:YAG laser, 355nm). As a consequence, we could obtain nano-scale photo-polymerized C60 clusters, which appear as round-shaped nano- scale particles in high resolution transmission electron-microscopy (HRTEM) images. However, the yield of the nano-scale C60 clusters obtained by this method is too small. So we designed and developed a system to obtain C60 cluster of macroscopic quantity by using ultrasonic nebulizer. In this system, C60 solution was vaporized to several micro-sized droplets in vacuum, resulting in the formation of C60 aggregates by evaporating solvent (toluene). The system was invented to produce nano-scale carbon clusters by the irradiation of UV light upon C60 aggregates in vacuum. We have characterized the products, C60 cluster, obtained from the system by using UV absorption spectra and HPLC spectra. Although the products have a possibility of inclusion various forms of C60 cluster, results support that the product formed from the system by using vaporizer method establishes a new method to obtain C60 cluster in macroscopic quantity. In the presentation, the details of the system and the results of characterization are reported.

  • PDF

Influence of Sample Preparation Method and Silver Salt Types on MALDI-TOFMS Analysis of Polybutadiene

  • Choi, Sung-Seen;Ha, Sung-Ho
    • Macromolecular Research
    • /
    • 제16권2호
    • /
    • pp.108-112
    • /
    • 2008
  • Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis of nonpolar polymeric materials is affected by the sample preparation as well as the matrix and cationizing agent. This study examined the influence of silver salt types on the MALDI analysis of polybutadiene (PB). Silver trifluoroacetate (AgTFA), silver benzoate (AgBz), silver nitrate ($AgNO_3$), and silver p-toluenesulfonate (AgTS) were used as the silver salts to compare the MALDI mass spectra of PB. The mixture solution of PB and 2,5-dihydroxybenzoic acid (DHB), as a matrix dissolved in THF, was spotted on the sample plate and dried. A droplet of the aqueous silver salt solution was placed onto the mixture. The mass spectrum with AgBz showed the clear $[M+Ag]^+$ ion distribution of PB while the mass spectrum with AgTFA did not show $[M+Ag]^+$ ions but only silver cluster ions. The mass spectra with $AgNO_3$ and AgTS did not show a clear $[M+Ag]^+$ ion distribution. The difference in the formation of $[M+Ag]^+$ ions of PB depending on the silver salts was attributed to the silver cation transfer reaction between the silver salt and the matrix (DHB). The mass spectrum showed a clear $[M+Ag]^+$ ion distribution of PB when the conjugate acid of the silver salt was less acidic than the matrix.