• Title/Summary/Keyword: Drop methods

Search Result 618, Processing Time 0.024 seconds

Eye Irritation Test of Fel Ursi Pharmacopuncture Solutions for Eye Drop (점안용 웅담약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.93-97
    • /
    • 2008
  • Objective: This study was done to investigate the safety of Fel Ursi pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: I suggested that Fel Ursi pharmacopuncture solution didn't induced eye irritation in rabbits.

Eye Irritation Test of Fel Ursi & Bovis Calculus Pharmacopuncture Solutions for Eye Drop (점안용 웅담.우황약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.99-104
    • /
    • 2008
  • Objective: This study was done to investigate the safety of Fel Ursi & Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: I suggested that Fel Ursi & Bovis Calculus pharmacopuncture solution didn't induced eye irritation in rabbits.

냉연 강판의 폭방향 판두께 제어 기술

  • 배원형;박해두;최재찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.512-517
    • /
    • 1993
  • The cold rolled strip meets continuously rising demands on the less deviation of thickness at the width direction of their rolled products. Especially, the special interest has been to find the methods to reduce the edge drop which influences seriously on the yield losses and the quality of the rolled products. In this study, the influence of hot coils on the thickness profile of cold rolled strip was analyzed. For obtainint the tapered work roll shig\ft conditions, the thermal crown and the flattening between the work roll and the strip were calculated, and the main parameters which have mostly effects on the edge drop were simulated. Also the obtained conditions from the simulation were applied to Tandem Cold Rolling Mill to investigate the change of the edge drop and the crown ratio depending on the amount of work roll taper and the length of contact of taper. The results of the application led to better thickness profile than conventional one.

  • PDF

Eye Irritation Test of Soyeom Pharmacopuncture Solution for Eye Drop (점안용 소염약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.2
    • /
    • pp.75-79
    • /
    • 2008
  • Objectives This study was done to investigate the safety of Soyeom pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results 1. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions I suggested that Soyeom pharmacopuncture solution didn't induced eye irritation in rabbits.

Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop (점안용 우황약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.2
    • /
    • pp.81-85
    • /
    • 2008
  • Objective This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60). After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions I suggested that Bovis Calculus pharmacopuncture solution didn't induced eye irritation in rabbits.

Prediction of Dynamic Power Consumption and IR Drop Analysis by efficient current modeling (효율적 전류모델을 이용한 고속의 전압 강하와 동적 파워 소모의 분석 기술)

  • Han, Sang-Yeol;Park, Sang-Jo;Lee, Yun-Sik
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.63-72
    • /
    • 2004
  • The supply voltage has been drop rapidly and the total length of the wire increased exponentially in the nanometer SoC design environment. The ideal supply voltage was dropped sharply by the resistance and parasitic devices which stayed on the kilometers-long wire length. Even worse, it could severely affect the functional behavior of the block of the design. To analyze the effects of the long wire of the SoC while maintaining the accuracy, the modeling of the current and the RC conversion of the parasitic techniques are researched and applied. By these modeling and conversion, the multi-million gates HDTV Chipset can be analyzed within a day. The benchmark analysis of the HDTV SoC showed the superiority to the conventional methods in performance and accuracy.

  • PDF

Prediction of drop size by analysis of conical liquid sheet breakup (원추형 액막분열 해석에 의한 액적 크기 예측)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.2 no.1
    • /
    • pp.8-17
    • /
    • 1997
  • A study has been carried out on the instability of a conical liquid sheet by using the linear instability theory. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed the the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. The predicted drop size agreed well with the measured Sauter mean diameter, $D_{32}$.

  • PDF

Development of Small Package Drop-Off System (PC 기반의 무인 소화물 접수장치 설계에 관한 연구)

  • Nam, Byong-Keun;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.450-452
    • /
    • 2001
  • In this paper, we proposed the automatic postal drop-off system based on the microprocessor board or PC. The weight of the small postal package is transmitted from the electronic scale and user-entered addresses and delivery rate are processed by the controller to calculate the fee. For 24 hour out-door operation and maintenance, non-cash payment methods such as credit card payment is used. The post stamp and receipt are printed by the thermal printer. For the electronic processing of the parcel, serial code is also printed on the stamp and receipts in bar code format. The parcel information obtained by the automatic postal drop-off system is transferred to remote central system by dial-up modem shared by the on site office. The proposed system and its control software are built for prototype model operation and the result met the design requirements. For real time processing, data reception through three serial ports is handled by interrupt routine. The proposed system is expected to be applied for commercial logistics system and pc automation system.

  • PDF

The effect of Arch Support Taping on Plantar Pressure and Navicular Drop Height in subjects with Excessive pronated foot during 6 Weeks (6주간의 활지지 테이핑(arch support taping) 적용이 과도하게 엎침된 발의 발바닥압력과 발배뼈 높이에 미치는 영향)

  • Kim, Tae-Ho;Koh, Eun-Kyung;Jung, Do-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.489-496
    • /
    • 2011
  • Purpose : The purpose of this study was to identify the effect of an arch support taping on navicular drop height and plantar pressure in the subjects with excessive pronated foot for 6 weeks. Methods : The fifteen subjects with the pronated foot group and the fifteen subjects with the normal foot group volunteered for this study. Both groups were applied arch support taping at 3 times a week during 6 weeks. Subjects were assessed navicular drop test to evaluate pronation of subtalar joint and plantar pressure on treadmill for pressure measuring system during walking with a bare foot state at pre- taping, after 3 weeks, and after 6 weeks. A two-way repeated analysis of variance design was used to examine the difference of navicular drop height and plantar pressure in the pronation foot group and the normal foot group. Results : The pronated foot group had significantly decreased both the navicular drop height and the plantar pressure under the medial midfoot than the normal foot group after 6 weeks(p<.01). Conclusions : This study proposed that an arch support taping can be support to lift navicular bone as well as to transfer the foot pressure from medial midfoot to lateral midfoot in individuals with excessive pronated foot.

Drop Analysis of a Package and Cushion Performance of Drum Washing Machine (드럼 세탁기 포장재 낙하해석 및 완충 특성)

  • Kim, Chang-Sub;Bae, Bong-Kook;Sung, Do-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1733-1740
    • /
    • 2010
  • The analysis of the dynamic behavior of the packaging of a drum washing machine has been carried out under the drop impact conditions. LS-DYNA software is used for performing the finite element analysis, and the validations are performed by comparing with the impact acceleration, effective stress and deformation of cushioned package with high-speed camera during free drop test. By analyzing the cushion characteristics and the design parameters of the original packaging, a packaging with an improved design is developed, and this design is validated on the basis of the results of the distribution test which consists of drop test, vibration test, stacking test, squeez test and so on. The drop impact simulation and analysis methods developed in this study can be adopted to successfully improve the cushioning provided by the packaging and to reduce the cost involved in developing new packaging for drum washing machines.