충격시험에 따른 배의 허용낙하높이 추정 (Estimation of Allowable Drop Height for Oriental Pears by Impact Tests)

  • 김만수;정현모;서륜;박일규;황용수
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.461-468
    • /
    • 2001
  • Impact between fruits and other materials is a major cause of product damage in harvesting and handling systems. The oriental pears are more susceptible to bruising than other fruits such as European pears and apples, and are required more careful handling. The interest in the handling of the pears for the processing systems has raised the question of the allowable drop height to which pears can be dropped without causing objectionable damage. Drop tests on pears were conducted using an impact device developed by authors to estimate the allowable drop height without bruising. The impact device was constructed to hold in a selected orientation and to release a fruit by vacuum for dropping on to a force transducer. The drop height was adjustable for zero to 60 cm to achieve the desired distance between the bottom of the fruits and the top of the impact force transducer. The transducer was secured to 150 kg$\sub$f/ concrete block. The transducer signal was sampled every 0.17 ms with a strain gage measurement board in the micro computer where it was digitaly stored for later analysis. The selected sample fruit was Niitaka cultivar of pears which is one of the most promising fruit for export in Korea. The pears were harvested during the 1998 harvest season from an orchard in Daejeon. The sample fruit was selected from two groups which were stored for 3 months and 5 months respectively by the method of current commercial practice. The pears were allowed to stabilize at environmental condition(18$^{\circ}C$, 65% rh) of the experimental room. One hundred fifty six pears were tested from the heights of 5, 7.5. 10 and 12.5 cm while measurement were made of impact peak force, contact time, time to peak force, dwell time, pear diameter and mass. The bioyield strength and modulus of elasticity were measured using UTM immediately after each drop test. The allowable drop height was estimated on the base of bioyield strength of the pears in two ways. One was assumed the peak force during impact test increasing linearly with time, and the other was based on the actual drop test results. The computer program was developed for measuring the impact characteristics of the pears and analyzing the data obtained in the study. The peak force increased while contact times decreased with increasing drop height and contact times of the sample from the hard tissue group. The allowable drop height increased with increasing bioyield strength and contact times, and also varied with Poisson\`s ratio, mass and equilibrium radius of the pears. The allowable drop height calculated by a theoretical method was in the range from 1 to 4 cm, meanwhile, the estimated drop height considering the result of the impact test was in the range from 1 to 6 cm. Since the physical properties of fruits affected significantly the allowable drop height, the physical properties of the fruits should be considered when estimating the allowable drop height.

  • PDF

90° 요철이 설치된 정사각 덕트 내 압력강하에 곡관부 및 회전이 미치는 영향 (Influence of Turning Region and Channel Rotation on Pressure Drop in a Square Channel with Transverse Ribs)

  • 김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.126-135
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. The square duct has a hydraulic diameter $(D_h)$ of 26.7 mm, and $1.5mm{\times}1.5mm$ square $90^{\circ}-rib$ turbulators are attached on the leading and trailing walls. The pitch-to-rib height ratio (p/e) is 10. The distance between the tip of the divider and the outer wall of the duct is $1.0D_h$ and the width of divider wall is 6.0mm or $0.225D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 to exclude the Reynolds effect, and the rotation number (Ro) is varied from 0.0 to 0.20. The pressure drop distribution, the friction factor and thermal performance are presented for the leading, trailing and the outer surfaces. It is found that the curvature of the $180^{\circ}$-turn produces Dean vortices that cause high pressure drop in the turn. The channel rotation results in pressure drop discrepancy between leading and trailing surfaces so that non-dimensional pressure drops are higher on the trailing surface in the first-pass and on the leading and side surfaces in the second-pass. In the turning region, Dean vortices shown in the stationary case transform into one large asymmetric vortex cell, and subsequent pressure drop characteristics also change. As the rotation number increases, the pressure drop discrepancy enlarges.

Inkjet 공정에서 발생하는 TIPS Pentacene Crystalline Morphology 변화에 따른 OTFT 특성 연구

  • 김교혁;성시현;정일섭
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.379-379
    • /
    • 2013
  • 본 논문에서는 Normal ink jetting 공법으로 OTFT를 제작할 때 coffee stain effect에 의해서 반도체 소자의 특성이 저하되는 것을 극복하기 위해서 동일한 위치에 동일한 부피로 Droplet을 형성하는 Multiple ink jetting 공법을 통해 TIPS pentacene 결정의 Morphology와 전기적 특성이 어떻게 변화하는지 알아 보았다. Multiple ink jetting의 drop 횟수가 증가할수록 coffee stain effect에 의해서 형성된 가운데 영역의 Dendrite grain이 점점 작아지다가 7 Drops 이후로는 Big grain 만 남게 되었다. Active layer의 표면 Roughness는 drop 횟수가 증가할수록 낮아지다가 일정 count 이후로는 다시 높아지는 것을 확인할 수 있었다. 전계 이동도(mobility)는 drop 횟수가 증가할수록 커지다가 일정 count 이후로는 saturation되는 것을 확인할 수 있었다. Multiple ink jetting에 의해서 만들어진 OTFT 소자의 전계 이동도(mobility)는 1 drop과 10 drops에서 각각 0.0059, 0.036 cm2/Vs 로 6배 정도 차이가 있었다. 이것은 첫 drop에 의해 만들어진 가운데 Dendrite grain 영역이 Multiple ink jetting을 반복하면서 점점 작아지게 되어 사라지고 두꺼운 Grain 영역만 남게 된 것으로 판단된다. Vth 와 On/Off ratio는 1 drop과 10 drops에서 각각 -3 V, -2 V 그리고 $3.3{\times}10^3$, $1.0{\times}10^4$를 보였다. OTFT의 substrate로 Flexible한 polyethersulfone (PES) 기판을 사용하였고, 절연체로 Spin coating된 Poly-4-vinylphenol (PVP)가 사용되었으며, Gate 및 Source/Drain 전극은 Au를 50 nm 두께로 증착하였다. Channel의 width와 length는 각각 100 um, 40 um 였고, Gate 전극 위에 Active layer를 형성한 Bottom gate 구조로 제작되었다. Ink jet으로 제작된 TIPS pentacene의 결정성은 x-ray diffraction (XRD)와 광학 현미경으로 분석하였고 Thickness profile은 알파스텝 측정기를 이용하였으며, OTFT의 전기적 특성은 Keithley-4,200을 사용하여 측정하였다.

  • PDF

균일전기장에 의한 기포와 액적의 변형에 관한 연구 (A study on the deformation of a bubble and a drop in a uniform electric field)

  • 권영철;김무환;강인석;조혜정;김석준
    • 대한기계학회논문집B
    • /
    • 제20권6호
    • /
    • pp.2023-2035
    • /
    • 1996
  • In the present study, the characteristics of the electrical deformation of a bubble and a drop under a uniform electric field have been investigated to understand EHD heat transfer enhancement by an electric field. The deformation of the bubble and the drop have been studied theoretically using an electric normal stress acting on their interfaces and assured by the numerical analysis and the experiment. From the variation of bubble volume and free energy, it is found that a bubble is compressed in an electric field and free energy had larger value with increasing W and the permittivity of a dielectric fluid. The electric normal stress induced on the interface of the bubble and the drop is different. Because of the surface charge induced at the drop interface, the electric normal stress acting on the drop is much larger than that of the bubble. The drop is, therefore, deformed much more than the bubble. In addition, the experimental and numerical results show that the aspect ratio and the contact angle of the bubble increase with increasing W.

납작관의 종횡비가 R-410A 증발열전달 및 압력손실에 미치는 영향 (Effect of Aspect Ratio of Flat Tube on R410A Evaporation Heat Transfer and Pressure Drop)

  • 김내현;이을종;변호원
    • 대한기계학회논문집B
    • /
    • 제37권4호
    • /
    • pp.395-404
    • /
    • 2013
  • 본 연구에서는 내경 5.0mm 원관을 납작하게 한 납작관에 대하여 R-410A를 사용하여 증발열전달 실험을 수행하였다. 실험은 포화온도를 $15^{\circ}C$로 고정한 상태에서 열유속을 $5{\sim}15kW/m^2$, 질량유속을 $200{\sim}400kg/m^2s$로 변화시키며 수행되었다. 실험결과 납작관의 종횡비가 증가할수록 열전달계수와 압력손실 모두 증가하였는데 특히 종횡비 4 인 경우 증가폭이 현저하였다. 납작관의 실험결과를 기존 상관식들과 비교한 결과 열전달계수는 Shah 상관식, 마찰계수는 Jung and Radermacher 상관식이 적절히 예측하였다.

종횡비가 다른 납작관 내 응축열전달 및 압력손실 (Condensation Heat Transfer and Pressure Drop in Flat Tubes with Different Aspect Ratios)

  • 김내현;박지훈;차상진
    • 대한기계학회논문집B
    • /
    • 제34권12호
    • /
    • pp.1111-1119
    • /
    • 2010
  • 본 연구에서는 내경 5.0mm 원관을 납작하게 한 납작관에 대하여 R-410A 를 사용하여 응축열전달 실험을 수행하였다. 실험은 포화온도와 열유속을 각각 $45^{\circ}C$ 와 10kW/$m^2$으로 고정한 상태에서 질량유속과 건도를 변화시키며 수행되었다. 실험결과 납작관의 종횡비가 열전달계수에 미치는 영향은 유동양식에 따라 달리 나타났다. 환상류에서는 종횡비가 증가할수록 증가하고 성층류에서는 종횡비가 증가할수록 감소하였다. 한편 납작관의 마찰손실은 종횡비가 증가할수록 증가하였다. 기존 상관식들은 납작관의 열전달계수와 마찰계수를 적절히 예측하였다.

낙차공이 있는 복단면 수로에서 사주거동의 수치분석 (Numerical Analysis of the Behavior of Bars in a Compound Channel with a Drop Structure)

  • 김기정;장창래
    • Ecology and Resilient Infrastructure
    • /
    • 제3권1호
    • /
    • pp.14-21
    • /
    • 2016
  • 본 연구에서는 2차원 수치모형을 이용하여 복단면 하도에서 낙차공을 고려하여 하도 변화와 사주의 거동 특성을 분석하였다. 교호사주에 의하여 흐름이 분리되며, 사주의 선단부에서 흐름이 집중되고 수충부가 형성되었다. 낙차공에 의하여 흐름은 하도 전체에 균등하게 분산되었으며, 낙차공 하류에서는 흐름이 집중되고 하상고가 낮아졌다. 그러나 사주의 형상은 낙차공 상류의 영향을 받아 교호사주의 형상을 유지되었다. 하폭 대 수심이 증가하면서 교호사주, 중앙사주, 복렬사주가 형성되었으며, 사주의 수가 증가하였다. 낙차공에 의하여 흐름이 집중되어 낙차공 상류에서 사주길이보다 낙차공 하류에서 사주길이가 더 짧게 나타났다.

수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구 (Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes)

  • 노건상;오후규
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

새로운 데드타임 및 전압강하의 보상을 이용한 SVPWM 인버터의 성능개선 (Improved Performance of SVPWM Inverter Based on Novel Dead Time and Voltage Drop Compensation)

  • 이동희;권영안
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권9호
    • /
    • pp.618-625
    • /
    • 2000
  • Recently PWM inverters are widely utilized for many industrial applications e.g. high performance motor drive and PWM techniques are newly developed for an accurate output voltage. Among them space voltage vector PWM(SVPWM) inverter has high voltage ratio and low harmonics compared to the conventional sinusoidal PWM inverter. However output voltage of PWM inverter is distorted and has error duet o the conducting voltage drop of switching devices and the dead time that is inevitable to prevent the shoot-through phenomenon. This paper investigates 3-phase SVPWM inverter which has a new compensation method against dead time and voltage drop. Proposed algorithm calculates gate pulse periods which directly compensates the dead time and nonlinear voltage drop without modification of reference voltages. Direct compensation of gate pulse periods produces exact output voltage and does not need additional circuits. The propose algorithm is verified through the simulation and experiments.

  • PDF

마이크로핀관내에서 R-22와 R-4O7C의 응축압력강하 특성에 관한 실험적 연구 (Experimental study for the pressure drop of R-22 and R-4O7C during the condensation in the micro-fin tubes)

  • 노건상
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.715-722
    • /
    • 2007
  • Experiments were conducted for the investigation of pressure drop inside horizontal micro-fin tubes during the condensation of R-22 and ternary refrigerant. R-407C(HFC-32/125/134a 23/25/62 wt%) as a substitute of R-22. The condenser is a double-tube and counterflow type heat exchanger which is consisted with micro-fin tubes having 60 fins with a length of 4000mm, outer diameter of 9.53mm and fin height of 0.2mm. The mass velocity varied from 102.1 to $301.0kg/(m^2{\cdot}s)$ and inlet quality was fixed as 1.0. From the experimental results. the pressure drop for R-407C was considerably higher than that for R-22. The value of PF(penalty factor) for both of refrigerants was not bigger than the ratio of micro-fin tube area to smooth tube area. Based on the experimental data. correlation was Proposed for the prediction of frictional pressure drop during the condensation of R-22 and R-407C inside horizontal micro-fin tubes.