• Title/Summary/Keyword: Drone standard

Search Result 48, Processing Time 0.027 seconds

A Study on the Characteristic Analysis of the Pest Control Drones Using Smart Operating Mode (스마트운영모드를 활용한 방제드론 특성분석에 관한 연구)

  • Lim, Jin-Taek
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.10
    • /
    • pp.108-113
    • /
    • 2019
  • In relation to $4^{th}$ industrial revolution, it is required to build a smart agricultural system using the pest control drones, which are emerging fast these days as a role to support pest control work of farmers and improve aging issues in farming. However, the absence of accurate criteria on management of the pest control drones and the effect of pesticide application is leading to damage to crops by pesticides. The extreme shortage of analysis of management of the pest control drones and relevant studies, and big differences in pest control efficiency depending on the operation skills of controllers are the biggest reasons for the damage. Therefore, this paper suggests a basic study on agricultural pest control drone operation system buildup to make out working schedules and calculate the dosage of pesticide by understanding the features of the pest control drones properly based on the control using smart operating mode.

A Study of QRS Complex Detection using the Spatial Velocity (공간속도 알고리즘을 이용한 QRS 컴플레스 검출에 관한 연구)

  • 권혁제;이명호
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.263-273
    • /
    • 1996
  • The time instants, at which QRS complexes are detected, are used in the electrocardioyam rhythm analysis. Hence, it is necessary that all QRS complexes are detected and that no other waves or artifacts are wrongly labeled as such. These time instants are also used in other tasks as an indication of the location of significant events in the ECG. For example, the QRS typification algorithm uses these points to define the region of interest for complex comparison and alignment. When waveform recognition is drone for each complex, these points are used to define search intervals in which the onset and the end of the QRS nmplex have to be found This paper proposes the method for the detection of QRS complexes and decision rule for the classification scheme. The efficiency of the detection is demonstrated with the aid of an internationally validated CSE(Common Standard for Quantitative Electrocardioyaph) data set 3 and 4.

  • PDF

Wave Propagation Modeling and Receiving Characteristics for ILS Navigation Signal (ILS 항행안전신호 전파진행 모델링 및 수신 특성 연구)

  • Kyung-Soon Lee;Kyung Heon Koo
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.3
    • /
    • pp.375-378
    • /
    • 2024
  • The instrument landing system (ILS) is an international standard established by the International civil aviation organization (ICAO) as one of the landing support facilities for aircraft. This system consists of a localizer (LOC) that provides orientation information about the runway to indicate the approach direction, a glide path (GP) that indicates the appropriate approach glide slope, and three of marker beacons (MB) that indicates the distance to the runway landing edge. In this study, we predicted the received signal strength by altitude and distance for LOC signals transmitted from the ground and analyzed the difference with the signal strength measured in the actual environment. Our objective is to develop signal strength prediction technology and apply it to the real environment.

Vertical Measurement and Analysis of Meteorological Factors Over Boseong Region Using Meteorological Drones (기상드론을 이용한 보성 지역 기상 인자의 연직 측정 및 분석)

  • Chong, Jihyo;Shin, Seungsook;Hwang, Sung Eun;Lee, Seungho;Lee, Seung-Hyeop;Kim, Baek-Jo;Kim, Seungbum
    • Journal of the Korean earth science society
    • /
    • v.41 no.6
    • /
    • pp.575-587
    • /
    • 2020
  • Meteorological phenomena are observed by the Korea Meteorological Administration in a variety of ways (e.g., surface, upper-air, marine, ocean, and aviation). However, there are limits to the meteorological observation of the planetary boundary layer (PBL) that greatly affects human life. In particular, observations using a sonde or aircraft require significant observational costs in economic terms. Therefore, the goal of this study was to measure and analyze the meteorological factors of the vertical distribution of the see-land breeze among local meteorological phenomena using meteorological drones. To investigate the spatial distribution of the see-land breeze, a same integrated meteorological sensor was mounted on each drone at three different points (seaside, bottom of mountain, and mountainside), including the Boseong tall tower (BTT) at the Boseong Standard Weather Observatory (BSWO) in the Boseong region. Vertical profile observations for air temperature, relative humidity, wind direction, wind speed, and air pressure were conducted up to 400 m every 30 minutes from 1100 LST to 1800 LST on August 4, 2018. The spatial characteristics of meteorological phenomena for temperature, relative humidity, and atmospheric pressure were not shown at the four points. Strong winds (~8 m s-1) were observed from the midpoint (~100 m) at strong solar radiation hour, and in the afternoon the wind direction changed from the upper layer at the inland area to the west wind. It is expected that the analysis results of the lower atmospheric layer observed using the meteorological drone may help to improve the weather forecast more accurately.

Safety Management of Steel Pipe Scaffold using UAV (무인항공기(UAV)를 활용한 건설현장 가시설물 안전관리)

  • Jun, Byong-Hee;Kim, Nam-Gyun;Jun, Kyo-Won;Choi, Bong-Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.59-67
    • /
    • 2019
  • In this study, the UAV (Unmammed Aerial Vehicle) was applied for the photogrammetry of the construction site and the safety management of steel pipe scaffold. The research site is a temporary facility for building reinforcement on Samcheok Campus of Kangwon National University. The installation condition of the steel pipe scaffold was investigated, and the pillar distance, the beam distance and the wale distance were surveyed. As a result, it was found that the beam distance of the scaffold in the longitudinal direction was in good agreement with the standard, but the pillar distance and the wale distance were found to be less than the standard. Three-dimensional data can be used in drone shooting to enable three-dimensional measurement, so that it is possible to measure facilities hidden or located inside other facilities. Through the drone shooting, the condition of the site can be quickly recorded and the surveying can be carried out without interfering with the work of the field personnel. Although the installation of the temporary structure must be strictly observed to ensure the safety of the workers, it is found that the installation standards are still neglected in the field. In order to prevent this practice, it was thought that the legal system should be supplemented so that it could be checked periodically by using UAV in the field process management.

An Analytical Study on the Durability Standard of Ground Structures Monitoring Sensors (지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2021
  • Purpose & Method: The purpose of this study is the theoretical study on the durability standard of ground structures monitoring sensors. A survey on the durability criteria for construction monitoring sensors of domestic construction companies and the income tax implementation regulations, the standard years of contents such as buildings and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. Result: The durability criterion such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the ground structure, is 8 to 10 years. Conclusion: The actual durability analysis by comparing the reliability of various monitoring sensors installed in dams at home and abroad, As a result of comprehensive study on the loss and damage rate of the maintenance monitoring sensor installed in the tunnel, the proper durability period of the built-in type monitoring sensor such as domestic pore pressure meter and earth pressure meter installed in the structure or the ground is 5 to 8 years it seems reasonable.

Experimental application of drone imagery for estimating streamflow based on remote sensing (원격탐사기반 하천유량추정을 위한 드론영상의 실험적 활용)

  • Kim, Jin Gyeom;Kang, Boo Sik;Kim, Dong Su;You, Ho Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.496-496
    • /
    • 2017
  • 위성을 이용한 원격탐사 기술이 발전하고 다양한 산출물이 나타남에 따라 수자원 및 하천관리에서의 원격탐사기술의 활용의 폭이 넓어지고 있다. 특히, 위성에서 관측할 수 있는 다양한 정보들을 이용하여 수자원 및 하천관리에 사용하려하는 연구가 활발히 진행되고 있으며, 기본적인 가시영상 이외에도 적외영상, 초분광영상, 수위정보, 레이더 반사도 등을 활용하여 수문량을 추정하려는 시도가 이루어져왔다. 원격탐사의 대표적인 장비인 위성은 광범위한 정보를 쉽게 취득할 수 있지만 위성마다 탑재된 센서에 따라 획득할 수 있는 자료가 서로 다르고, 산출물의 시공간 해상도에 따라 자료의 질이 결정된다. 본 연구에서는 원격탐사영상을 이용한 하천유량추정기법을 수립하기 위해 통제된 실험하천 규모에서 드론을 이용하였다. 실험은 대한민국 안동에 위치한 한국건설기술연구원 하천실험센터에서 수행되었으며, DJI Phantom 3 standard 드론을 활용하여 영상을 획득하였다. 하천유량추정의 방법론은 운동량 방정식과 Manning 유속공식을 활용한 하폭기반 유량추정 기법을 수립하였다. 1차 실험은 하천유량을 증가시키고 감소시키는 동시에 드론을 이용하여 하천을 촬영함으로써 하폭의 변화와 동시에 유량의 변화를 추정할 수 있는지 확인하였다. 2차 실험에서는 배수효과가 존재하는 조건에서 드론영상을 이용한 하천유량을 산정하고 보정계수를 산정하였다. 본 연구에서 수립된 하천유량추정기법은 위성영상을 이용한 하천유량 추정에 활용할 수 있으리라 기대한다.

  • PDF

A Study on Analysis of Construction Monitoring Cost and Improvement Measures of Railway Tunnel Construction in Seoul (서울시 철도터널 건설공사의 공사계측비 분석 및 개선방안 연구)

  • Jong-Tae Woo
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.18-30
    • /
    • 2023
  • Purpose: This study is to contribute to the development of monitoring technology through the increase of confidence in construction monitoring by deriving the analysis of construction monitoring cost and improvement measures of railway tunnel construction in Seoul. Method: It presents the status on design and contract of construction monitoring cost, status on application construction monitoring cost and its analysis, analysis on safety management cost and quality management cost, expansion of application of the price calculation standard for monitoring management services to improve this, and monitoring for direct order of ordering organization. Results: If the monitoring management service that was meanwhile ordered as included in the construction work is performed by the directly selected company of ordering organization through the preliminary screening for bidding qualification, then the improvement of monitoring quality and the accurate monitoring data can be secured. Conclusion: For the price calculation standard for monitoring management service, the application of actual cost addition method under the Engineering Promotion Act and the calculation standard of monitoring management cost for standard estimation for ground survey should be extended through the direct order of ordering organization, not the method to be included in the net construction cost where it is performed by a subcontractor via contractor.

Evaluation of vegetation index accuracy based on drone optical sensor (드론 광학센서 기반의 식생지수 정확도 평가)

  • Lee, Geun Sang;Cho, Gi Sung;Hwang, Jee Wook;Kim, Pyoung Kwon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.2
    • /
    • pp.135-144
    • /
    • 2022
  • Since vegetation provides humans with various ecological spaces and is also very important in terms of water resources and climatic environment, many vegetation monitoring studies using vegetation indexes based on near infrared sensors have been conducted. Therefore, if the near infrared sensor is not provided, the vegetation monitoring study has a practical problem. In this study, to improve this problem, the NDVI (Normalized Difference Vegetation Index) was used as a reference to evaluate the accuracy of the vegetation index based on the optical sensor. First, the Kappa coefficient was calculated by overlapping the vegetation survey point surveyed in the field with the NDVI. As a result, the vegetation area with a threshold value of 0.6 or higher, which has the highest Kappa coefficient of 0.930, was evaluated based on optical sensor based vegetation index accuracy. It could be selected as standard data. As a result of selecting NDVI as reference data and comparing with vegetation index based on optical sensor, the Kappa coefficients at the threshold values of 0.04, 0.08, and 0.30 or higher were the highest, 0.713, 0.713, and 0.828, respectively. In particular, in the case of the RGBVI (Red Green Red Vegetation Index), the Kappa coefficient was high at 0.828. Therefore, it was found that the vegetation monitoring study using the optical sensor is possible even in environments where the near infrared sensor is not available.

District-Level Seismic Vulnerability Rating and Risk Level Based-Density Analysis of Buildings through Comparative Analysis of Machine Learning and Statistical Analysis Techniques in Seoul (머신러닝과 통계분석 기법의 비교분석을 통한 건물에 대한 서울시 구별 지진취약도 등급화 및 위험건물 밀도분석)

  • Sang-Bin Kim;Seong H. Kim;Dae-Hyeon Kim
    • Journal of Industrial Convergence
    • /
    • v.21 no.7
    • /
    • pp.29-39
    • /
    • 2023
  • In the recent period, there have been numerous earthquakes both domestically and internationally, and buildings in South Korea are particularly vulnerable to seismic design and earthquake damage. Therefore, the objective of this study is to discover an effective method for assessing the seismic vulnerability of buildings and conducting a density analysis of high-risk structures. The aim is to model this approach and validate it using data from pilot area(Seoul). To achieve this, two modeling techniques were employed, of which the predictive accuracy of the statistical analysis technique was 87%. Among the machine learning techniques, Random Forest Model exhibited the highest predictive accuracy, and the accuracy of the model on the Test Set was determined to be 97.1%. As a result of the analysis, the district rating revealed that Gwangjin-gu and Songpa-gu were relatively at higher risk, and the density analysis of at-risk buildings predicted that Seocho-gu, Gwanak-gu, and Gangseo-gu were relatively at higher risk. Finally, the result of the statistical analysis technique was predicted as more dangerous than those of the machine learning technique. However, considering that about 18.9% of the buildings in Seoul are designed to withstand the Seismic intensity of 6.5 (MMI), which is the standard for seismic-resistant design in South Korea, the result of the machine learning technique was predicted to be more accurate. The current research is limited in that it only considers buildings without taking into account factors such as population density, police stations, and fire stations. Considering these limitations in future studies would lead to more comprehensive and valuable research.