• 제목/요약/키워드: Driving Control Process

검색결과 233건 처리시간 0.02초

간호서비스 질에 대한 환자의 인식과 만족도 및 재방문의도와의 관계 (The Relationships among Patient's Perception, Patient's Satisfaction of Nursing Service Quality and Revisiting intention)

  • 이선아
    • 간호행정학회지
    • /
    • 제4권2호
    • /
    • pp.307-319
    • /
    • 1998
  • This study is an empirical investigation and study on the measurement of nursing service quality as perceived by patients. A series of H1. H2. H3 alternative hypotheses were tested using a sample of 250 patients in Taegu City. Korea. HI hypothese were tested for application of five component of service quality (SERVQlTAL and SE RPERF : tangiblity. reliability. responsiveness. accessibility. understandability) in Taegu area Hospitals. Validity test - the five components of service quality were rearranged into two components of service quality (personal factor. nonpersonal factor). Although SERVQUAL was verified in USA. application for five components of service quality in Korea indicated that it need more analytical studies. Nobody can deny the fact that the recent growth of the nursing service quality is one of the most important driving forces of hospital management. In many hospitals. the nursing quality charges more than 50% of the medical service quality. As a result. many hospital managers should be enormous interests in the investment potentiality of the nursing service. However. doesn't many researchers invest their time and effort on the research of the quality control in nursing service. Nursing service management is the process to satisfy customer's desires and expectations through the various service activities. Presently nursing service are being faced with three Common tasks of improving quality of nursing service. competitively differential advantage and productivity because of quantitative expansion of Nursing service. Such a phenomenon is also found in our medical service industry. resulting from increasing demands for medical service owing to national medical insurance policy and consumer's attitude change emphasizing prevention of illness. excessiveness of medical facilities in large cities and increasing medical lawsuits due to influence of consumerism. Therefore. under such circumstances. this research on nursing service is conducted from nursing managements to improve the nursing service quality problems faced by medical institutions. The results of this theoretical/empirical research are as follows: 1. Nursing service Quality is regarded as patients' perceived quality and evaluated on the basis (5 dimension) of technical and functional quality. 2. Nursing service Quality is a concept of patients evaluation on the measurable multi-dimensions intrinsic and extrinsic attributes of service. 3. Nursing service Quality is conceptually defined as the difference between the perceived service and the expected service. 4. Korean consumers trend to evaluate nursing service quality based on such dimensions as responsiveness and reliability. understandability. accessibility. tangibility. 5. After analyzing whether or not there are some differences in respective medical institution. it was found that there are significant difference on understandability. reliability. communicability. courtesy. competence. 6. After analyzing the difference between the expected nursing service and the nursing perceived service, it was found that the expected nursing service is higher than the perceived service in every medical institution. 7. HI hypothesis was tested with regard to the validity test between SERVQUAL and SERVPERF in nursing service quality. The result of validity test between SERVQUAL and SERVPERF was found to have differential result. That is the R2 of SERVPERF is higher than that of SERVQUAL. Therefore. HI was verified in nursing management. H2. H3 hypotheses were tested whether or not the nursing service quality and patient satisfaction is the preceding variable. The result of H2 hypothes is that the nursing service quality is the preceding variable of patient satisfaction and the patient satisfaction is that of revisiting intention. After analyzing whether or not there is any differences on the demographic variable of five nursing service quality factor. it was found that there are statistically significant differences on communicability and courtesy at the sex. understand ability. accessibility and tangibility at the age. understandability at the academic background respectively.

  • PDF

차량용 레이더를 위한 26GHz 40nm CMOS 광대역 가변 이득 증폭기 설계 (26GHz 40nm CMOS Wideband Variable Gain Amplifier Design for Automotive Radar)

  • 최한웅;최선규;이은규;이재은;임정택;이경혁;송재혁;김상효;김철영
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.408-412
    • /
    • 2018
  • 이 논문에서는 40nm CMOS 공정을 이용하여 제작된 26GHz 가변 이득 증폭기에 대한 연구를 수행하였다. 79GHz를 사용하는 자동차 레이더의 경우 주파수 특성상 회로 전체를 79GHz로 설계 및 매칭 하기 보다는 Down conversion 하여 낮은 주파수대역으로 구동하거나 Up conversion 전에 낮은 주파수 대역을 이용하는 것이 설계 및 구동에 유리하다. 실제적으로 TTD(True Time Delay)를 통해 시간지연을 이용하는 Phased Array System 의 경우에도 현재 기술로는 낮은 주파수로 Down conversion하는 것이 오차를 줄이고 실제적 시간지연을 구현하는데 좋다. 79GHz 주파수의 1/3인 26GHz 주파수 대역에서 동작하는 VGA(Variable Gain Amplifier)에 대하여 설계하였고 1-stage의 cascode amplifier 형태로 구성된 회로에서 VDD : 1V, Bias 0.95V, S11은 < -9.8dB(Mea. High gain mode), S22 <-3.6dB(Mea. High gain mode), Gain : 2.69dB(Mea. High gain mode), P1dB : -15 dBm (Mea. High gain mode) 로 설계되었다. Low gain mode 에서는 S11은 < -3.3dB(Mea. Low gain mode), S22 < -8.6dB(Mea. Low gain mode), Gain : 0dB(Mea. Low gain mode), P1dB : -21 dBm (Mea. Low gain mode)로 설계되었다.

Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석 (Analysis of Respiratory Motional Effect on the Cone-beam CT Image)

  • 송주영;나병식;정웅기;안성자;남택근;윤미선
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.81-86
    • /
    • 2007
  • 영상유도 방사선치료의 대표적 방법의 하나로 선형가속기에 부착된 on-board imager (OBI) 영상장치를 사용하여 획득한 cone-beam CT (CBCT) 영상이 정밀 방사선치료 시 환자 정렬 오류를 보정하는데 활용되고 있다. 본 연구에서는 CBCT 영상 획득 시 환자 호흡에 의한 영상 품질과 정보의 변화를 분석하고자 호흡 움직임을 모사할 수 있는 팬텀과 CBCT 영상획득용 팬텀을 제작하고, 여러 움직임 조건에서 획득한 CBCT 영상들과 정지상태에서 얻은 CBCT 영상과의 비교, 분석을 수행하였다. 분석대상 움직임 조건을 구성하는 요소로서 움직임 주기는 5가지(2초, 3초, 4초, 5초, 6초)를 선정하였고, 움직임 변위 크기는 4가지(0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm)를 선정하여 총 20가지의 움직임 조건에서 CBCT 영상을 획득하였다. CBCT 영상의 CT값의 상대적 크기로 비교한 영상 화소 값 강도의 평균 변화는 정지 상태의 영상과 비교하여 변위가 0.7 cm의 경우 71.07%, 1.6 cm의 경우 48.88%, 2.4 cm의 경우 30.60%, 3.1 cm의 경우 17.38% 값을 보였고, 팬텀 움직임 방향의 영상 길이는 정지상태에서 2.1 cm, 움직임 변위가 0.7 cm의 경우 2.66 cm, 1.6 cm의 경우 3.06 cm, 2.4 cm의 경우 3.62 cm, 3.1 cm의 경우 4.04 cm 값을 보여 움직임 변위 크기가 클수록 영상 품질 저하와 형태적 정보의 왜곡정도도 증가하였다. 움직임 주기에 의한 영상품질의 변화는 움직임 변위 크기가 작은 경우를 제외하고는 특별한 영향이 없었다. 본 연구를 통해 환자 호흡에 의한 움직임 변위가 큰 부위의 CBCT 영상을 획득할 때, 영상 품질과 정보에 변화가 발생할 수 있어 이 점을 고려하여 임상에 사용해야 하며, 궁극적으로 호흡 신호와 연동된 CBCT 영상이 필요함을 확인할 수 있었다.로버 + 혼파초지에 비하여 낮은 결과를 보였다(p<0.05). 2년 평균 CPDM 수량은 레드 클로버 + 혼파초지가 2,832kg으로 관행 혼파초지(2,372kg)나 잔디형 초종 + 혼파초지(2,266kg)에 비하여 높은 결과를 나타내었다(p<0.05). 2년 평균 DDM 수량은 레드 클로버 + 혼파초지가 8,881kg으로 관행 혼파초지(8,255kg)나 잔디형 초종 + 혼파초지(7,314kg)에 비하여 높은 결과를 얻었다(p<0.05). 2005년 5회 예취시의 식생비율은 관행 혼파초지는 orchardgrass는 45%, tall fescue 22%, Kentucky bluegrass 5% 및 white clover 24%이었으며, 레드 클로버 + 혼파초지는 orchardgrass 40%, tall fescue 22%, Kentucky bluegrass 4% 및 red clover 31%이었고, 잔디형 초종 + 혼파 초지는 orchardgrass 37%, 잔디형 초종 37%(tall fescue 23%, Kentucky bluegrass 6%, perennial ryegrass 8%) 및 white clover 23%를 유지하였다. 이상의 결과를 종합할 때, 초종과 파종비율에 따른 혼파초지의 건물수량과 사료가치의 차이를 확인할 수 있었으며, 레드 클로버 + 혼파 초지가 건물수량과 사료가치를 높이는데 효과적이었다.\ell}$ 이었으며 , yeast extract 첨가(添加)하여 배양시(培養時)는 yeast extract 농도(濃度)가 증가(增加)함에 따라 단백질(蛋白質) 함량(含量)도 증가(增加)하였다. 7. CHS-13 균주(菌株)의 RNA 함량(含量)은 $4.92{\times}10^{-2 }\;mg/m{\ell}$이었으며 yeast extract 농도(濃度)가 증가(增加)함에 따라 증가(增加)하다가 농도(濃度) 0.2%에서 최대함량(最大含量)을 나타내고

  • PDF