• 제목/요약/키워드: Driven steel pipe pile

검색결과 43건 처리시간 0.024초

항타강관말뚝과 현장타설말뚝의 주면마찰력 거동에 관한 현장실험 연구 (A Study on Friction Capacity Behavior for Driven Steel Pipe Pile and Drilled Shaft Pile with Field Test)

  • 정성민;이민희;송병덕;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1-8
    • /
    • 2005
  • In this study, static pile load tests for instrumented drilled shaft pile and instrumented driven steel pipe pile were performed. Based on the results of pile load test, skin friction of each stratum was compared. Skin friction of drilled shaft were more than those of driven pile at the same settlement. This was based on the difference of surface roughness of piles and pile construction methods.

  • PDF

FORM 신뢰성 기반 항타강관말뚝 저항계수 산정 (FORM Reliability-based Resistance Factors for Driven Steel Pipe Piles)

  • 박재현;허정원;이주형;정문경;곽기석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.779-783
    • /
    • 2008
  • LRFD Resistance factors for static bearing capacity of driven steel pipe piles were calibrated in the freamework of reliability theory. Reliability analysis was performed by the First Order Reliability Method (FORM) using resistance bias factor statistics.The target reliability indices are selected as 2.0 and 2.33 for group pile case and 2.5 for single pile case, based on the reliability level of the current design practice and considering redundancy of pile group, acceptable risk level, construction quality control, and significance of individual structure.

  • PDF

항타강관말뚝의 주면마찰저항 특성에 관한 현장실험 연구 (A Field Test Study on Skin Friction Behavior of Driven Steel Piles)

  • 이민희;이충숙;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.575-582
    • /
    • 2005
  • Static pile load tests for three instrumented driven steel pipe pies were performed. Based on the distributions of pile axial loads along the pile depth, Characteristics of unit skin friction were analyzed.

  • PDF

해상 LNG 인수시설 대구경 강관말뚝 시공 사례 연구 (A Case Study of large diameter steel pipe pile Foundation for Offshore LNG Facility)

  • 류대영;김형욱;장우영;최기병;조성한
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.70-77
    • /
    • 2010
  • In this paper, a case study of drivability and bearing capacity of large diameter steel pipe piles at PTT LNG site in Thailand is introduced. The LNG facilities were designed to be founded on steel pipe pile foundations driven into the weathered rock formation overlaid by sand layers. The drivability analyses of open ended pipe piles were carried out using GRL WEAP program and the bearing capacities of the piles were estimated. Dynamic load tests were performed to evaluate end bearing resistance, and it is shown that the measured end bearing resistance is smaller than the calculated end bearing because the plugging does not develop sufficiently in case of large diameter pipe piles.

  • PDF

점토지반에 타입된 콘크리트 말뚝의 인발저항 및 크리프 거동 (Uplift Capacity and Creep Behavior of Concrete Pile Driven in Clay)

  • 신은철;김종인;박정준;이학주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.371-378
    • /
    • 2001
  • The working load at pile is sometimes subjected to not only compression load but also lateral load and uplift forces. Pile foundation is essential and uplift load can be applied because of buoyancy, a typhoon, wind or seismic forces. This study was carried out to determine the uplift capacity of concrete pile foundation driven in clay. Pile was driven in clay, between pile and clay adhesion factor was estimated, and it is the mean value between the cast-in-situ-pile and steel pipe pile. When pile foundation is loaded for long time, creep behavior occurs. The behavior of creep is originated from the clay creep contacted with pile. The creep behavior of pile foundation embedded in clay is heavily depended on the thickness of clay around the pile shaft, pore water pressure in clay, and creep behavior of clay.

  • PDF

대구경 소켓경사반력말뚝의 인발거동에 관한 연구

  • 최용규;김상옥;정창규;정성기;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.277-284
    • /
    • 2000
  • Using the large diameter (D = 2,500mm, L = 40m) batter steel pipe piles, designed as compression piles but used as reaction piles during the static compression load test of socketed test piles (D = 1,000mm, L = 40m), static pile load tests for large diameter instrumented rock-socketed piles were performed. The reaction steel pipe piles were driven 20m into the marine deposit and weathered rock layer and then l0m socketed with reinforced concrete through the weathered rock layer and into hard rock layer. Steel pipe and concrete in the steel pile part, and concrete and rebars in the socketed parts were instrumented to measure strains in each part. The pullout amounts of reaction pile heads were also measured with LVDT. During the static pile load test, total compressional load of about 20MN was loaded on the head of test piles, but load above 20MN was not loaded due to lack of loading capacity of loading system. Over the course of the study, maximum pullout amount up to 7mm was measured in the heads of reaction piles when loaded op to 10MN and 1mm of pullout amount was measured. More than 85% of pullout load was transfered in the residual weathered rock layer and about 10% in the soft rock layer, which was somewhat different transfer mechanism in the static compressional load tests.

  • PDF

선단지지된 항타개단강관말뚝의 축하중전이거동 (Axial Load Transfer Behavior for Driven Open-ended End bearing Steel Pipe Pile)

  • 임태경;정성민;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.589-596
    • /
    • 2002
  • In this study, static pile load tests with load transfer measurement were accomplished in the field. Yield pile capacity (or ultimate pile capacity) determined by load-settlement-time relationship was determined and axial load transfer behavior was analyzed. In the test for the four test piles were behaved as end bearing pile but ratios of skin friction to total pile capacity were 27%∼33%.

  • PDF

LRFD 설계를 위한 국내 항타강관말뚝의 저항계수 산정 (Resistance Factors of Driven Steel Pipe Piles for LRFD Design in Korea)

  • 박재현;허정원;김명모;곽기석
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.367-377
    • /
    • 2008
  • 국내 기초구조물에 대한 하중저항계수설계법 개발의 일환으로 신뢰성에 기반한 항타강관말뚝의 저항계수를 산정하였다. 국내 정재하시험 및 지반조사 자료를 수집, 분석하여 측정 지지력 확인이 가능한 57개 자료에 대해서 선단부 N치 50을 기준으로 두 그룹으로 분류하였다(N<50, $N{\geq}50$). 구조물기초설계기준에서 제안하고 있는 두 가지 정역학적 설계공식에 대해서 대표 측정지지력과 설계지지력을 비교함으로써 저항편향계수를 평가하였다. 저항편향계수의 통계특성을 이용하여 일차신뢰도법 및 몬테카를로 시뮬레이션에 의한 엄밀한 신뢰성 분석을 실시하였다. 신뢰성 분석 결과 및 국내 말뚝기초의 설계, 시공 실무 특성을 종합적으로 고려하여 목표 신뢰도지수를 결정하였다. 무리말뚝의 여용성을 적용할 수 있는 경우 2.0, 2.33, 무리말뚝의 여용성을 적용할 수 없는 경우 2.5의 목표 신뢰도지수를 결정하였고, 일차신뢰도법 및 몬테카를로 시뮬레이션을 적용하여 저항계수를 산정하였다.

실제 설계 사례를 통한 항타강관말뚝의 LRFD 저항계수 검증 (Verification of LRFD Resistance Factors of Driven Steel Pipe Piles Using a Real Bridge Foundation Design)

  • 박재현;이주형;정문경;최영석;곽기석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.512-517
    • /
    • 2009
  • Resistance factors for static bearing capacity of driven steel pipe piles were calibrated in the framework of reliability theory. A comprehensive foundation design case study on an actual bridge was performed using resistance factors developed in this study. Comparing with Allowable Stress Design (ASD), LRFD design method provides quantitative evaluation of safety level of designed foundation and exhibits considerable potential economy in design.

  • PDF