• 제목/요약/키워드: Drift velocity

검색결과 227건 처리시간 0.023초

Polar Mesospheric Summer Echo Characteristics in Magnetic Local Time and Height Profiles

  • Young-Sook Lee;Ram Singh;Geonhwa Jee;Young-Sil Kwak;Yong Ha Kim
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권3호
    • /
    • pp.101-111
    • /
    • 2023
  • We conducted a statistical study of polar mesospheric summer echoes (PMSEs) in relation to magnetic local time (MLT), considering the geomagnetic conditions using the K-index (or K). Additionally, we performed a case study to examine the velocity profile, specifically for high velocities (≥ ~100 m/s) varying with high temporal resolution at high K-index values. This study utilized the PMSE data obtained from the mesosphere-stratosphere-troposphere radar located in Esrange, Sweden (63.7°N, 21°E). The change in K-index in terms of MLT was high (K ≥ 4) from 23 to 04 MLT, estimated for the time PMSE was present. During the near-midnight period (0-4 MLT), both PMSE occurrence and signal-to-noise ratio (SNR) displayed an asymmetric structure with upper curves for K ≥ 3 and lower curves for K < 3. Furthermore, the occurrence of high velocities peaked at 3-4 MLT for K ≥ 3. From case studies focusing on the 0-3 MLT period, we observed persistent eastward-biased high velocities (≥ 200 m/s) prevailing for ~18 min. These high velocities were accompanied with the systematic motion of profiles at 85-88 km, including large shear formation. Importantly, the rapid variations observed in velocity could not be attributed to neutral wind effects. The present findings suggest a strong substorm influence on PMSE, especially in the midnight and early dawn sectors. The large zonal drift observed in PMSE were potentially energized by local electromagnetic fields or the global convection field induced by the electron precipitation during substorms.

회전요동하는 원통내의 유동특성 - 수치해석 및 실험 (Fluid Flow in a Circular Cylinder Subject to Circulatory Oscillation-Numerical Analysis and Experiment)

  • 서용권;박준관
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.3970-3979
    • /
    • 1996
  • A fluid flow inside a circular cylinder subject to horizontal, circular oscillation is analyzed numerically and experimentally. The steady streaming velocities at the edges of the boundary layers on the bottom and side surfaces of the cylinder obtained in the previous paper are used as the boundary conditions in the governing equations for the steady flow motion in the interior region. The Stokes' drift velocity obtained in the previous paper also constitutes the Lagrangian velocity which is used in the momentum equations. It turns out that the interior steady flow is composed of one cell, ascending at the center and descending near the side surface, at the streaming Reynolds number 2500. However, at the streaming Reynolds number 25, the flow field is divided into two cells resulting in a descending flow at the center. The experimentally visualized flow patterns at the bottom surface agree well with the analytical solutions. The visualization experiment also confirms the flow direction as well as the center position of the cell obtained by the numerical solutions.

무궁화 위성의 궤도전이를 위한 최적 원지점 점화 계획 (OPTIMUM AKN BURN PLANNING FOR ORBITAL TRANSFER OF KOREASAT)

  • 송우영;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • 제11권2호
    • /
    • pp.296-307
    • /
    • 1994
  • 1995년 Deitall 발사체로 발사예정인 무궁화 위생을 전이궤도에서 표류궤도로 진입시키기 위해 실시하는 원지점 조정에 활용이 가능한 시뮬레이션 S/W률 VAX/VMS 에서 사용할 수 있도록 X-Window 시스템(OSF /MOTIF Graphic User Interface)을 이용하여 GUI(Graphical User Interface)를 통한 조작이 가능하도록 개발하였다. 이 S/W는 원지점 점화를 임펄스라 가정하여 조정 파라미터를 계산하는 데 필요한 데이터를 제공하는 분석모드와 상세하게 모델링된 원지점 모터를 이용하여 finite burn 적분으로 원지점 점화를 위한 조정 파라미터를 계산하는 운용모드 등 두 가지 모드를 제공한다. 또한 이 개발된 S/W를 이용하여 무궁화 위성의 궤도 전이를 위한 최척 원지점 점화에 대하여 여러가지 시나리오를 수행하고 그 결과를 분석해 보았다.

  • PDF

CF4 기체에서의 전리와 부착계수 (Ionization and Attachment Coefficients in CF4)

  • 김상남
    • 전기학회논문지P
    • /
    • 제60권1호
    • /
    • pp.27-31
    • /
    • 2011
  • In this paper, the electron transport characteristics in $CF_4$ has been analysed over the E/N range 1~300[Td] by a two-term approximation Boltzmann equation method and by a Monte Carlo simulation. The motion has been calculated to give swarm parameters for the electron drift velocity, longitudinal diffusion coefficient, the ratio of the diffusion coefficient to the mobility, electron ionization and attachment coefficients, effective ionization coefficient, mean energy, collision frequency and the electron energy distribution function. The electron energy distribution function has been analysed in $CF_4$ at E/N=5, 10, 100, 200 and 300[Td] for a case of the equilibrium region in the mean electron energy and respective set of electron collision cross sections. The results of Boltzmann equation and Monte Carlo simulation have been compared with experimental data by Y. Nakamura and M. Hayashi. The swarm parameter from the swarm study are expected to serve as a critical test of current theories of low energy electron scattering by atoms and molecules, in particular, as well as crucial information for quantitative simulations of weakly ionized plasmas.

Seismic responses of asymmetric steel structures isolated with the TCFP subjected to mathematical near-fault pulse models

  • Tajammolian, H.;Khoshnoudian, F.;Bokaeian, V.
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.931-953
    • /
    • 2016
  • In this paper, the effects of mass eccentricity of superstructure as well as stiffness eccentricity of isolators on the amplification of seismic responses of base-isolated structures are investigated by using mathematical near-fault pulse models. Superstructures with 3, 6 and 9 stories and aspect ratios equal to 1, 2 and 3 are mounted on a reasonable variety of Triple Concave Friction Pendulum (TCFP) bearings considering different period and damping ratio. Three-dimensional linear superstructure mounted on nonlinear isolators are subjected to simplified pulses including fling step and forward directivity while various pulse period ($T_p$) and Peak Ground Velocity (PGV) amounts as two crucial parameters of these pulses are scrutinized. Maximum isolator displacement and base shear as well as peak superstructure acceleration and drift are selected as the main engineering demand parameters. The results indicate that the torsional intensification of different demand parameters caused by superstructure mass eccentricity is more significant than isolator stiffness eccentricity. The torsion due to mass eccentricity has intensified the base shear of asymmetric 6-story model 2.55 times comparing to symmetric one. In similar circumstances, the isolator displacement and roof acceleration are increased 49 and 116 percent respectively in the presence of mass eccentricity. Furthermore, it is demonstrated that torsional effects of mass eccentricity can force the drift to reach the allowable limit of ASCE 7 standard in the presence of forward directivity pulses.

Ground motion intensity measure to evaluate seismic performance of rocking foundation system

  • Ko, Kil-Wan;Ha, Jeong-Gon
    • Earthquakes and Structures
    • /
    • 제21권6호
    • /
    • pp.563-576
    • /
    • 2021
  • The rocking foundation is effective for reducing structural seismic demand and avoiding overdesign of the foundation. It is crucial to evaluate the performance of rocking foundations because they cause plastic hinging in the soil. In this study, to derive optimized ground motion intensity measures (IMs) for rocking foundations, the efficiency of IMs correlated with engineering demand parameters (EDPs) was estimated through the coefficient determination using a physical modeling database for rocking shallow foundations. Foundation deformations, the structural horizontal drift ratio, and contribution in drift from foundation rotation and sliding were selected as crucial EDPs for the evaluation of rocking foundation systems. Among 15 different IMs, the peak ground velocity exhibited the most efficient parameters correlated with the EDPs, and it was discovered to be an efficient ground motion IM for predicting the seismic performance of rocking foundations. For vector regression, which uses two IMs to present the EDPs, the IMs indicating time features improved the efficiency of the regression curves, but the correlation was poor when these are used independently. Moreover, the ratio of the column-hinging base shear coefficient to the rocking base shear coefficient showed obvious trends for the accurate assessment of the seismic performance of rocking foundation-structure systems.

Improvement of the subcooled boiling model using a new net vapor generation correlation inferred from artificial neural networks to predict the void fraction profiles in the vertical channel

  • Tae Beom Lee ;Yong Hoon Jeong
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4776-4797
    • /
    • 2022
  • In the one-dimensional thermal-hydraulic (TH) codes, a subcooled boiling model to predict the void fraction profiles in a vertical channel consists of wall heat flux partitioning, the vapor condensation rate, the bubbly-to-slug flow transition criterion, and drift-flux models. Model performance has been investigated in detail, and necessary refinements have been incorporated into the Safety and Performance Analysis Code (SPACE) developed by the Korean nuclear industry for the safety analysis of pressurized water reactors (PWRs). The necessary refinements to models related to pumping factor, net vapor generation (NVG), vapor condensation, and drift-flux velocity were investigated in this study. In particular, a new NVG empirical correlation was also developed using artificial neural network (ANN) techniques. Simulations of a series of subcooled flow boiling experiments at pressures ranging from 1 to 149.9 bar were performed with the refined SPACE code, and reasonable agreement with the experimental data for the void fraction in the vertical channel was obtained. From the root-mean-square (RMS) error analysis for the predicted void fraction in the subcooled boiling region, the results with the refined SPACE code produce the best predictions for the entire pressure range compared to those using the original SPACE and RELAP5 codes.

VAD공정 관련 회전하는 원판으로의 입자 부착 (Particle deposition on a rotating disk in application to vapor deposition process (VAD))

  • 송창걸;황정호
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.61-69
    • /
    • 1998
  • Vapor Axial Deposition (VAD), one of optical fiber preform fabrication processes, is performed by deposition of submicron-size silica particles that are synthesized by combustion of raw chemical materials. In this study, flow field is assumed to be a forced uniform flow perpendicularly impinging on a rotating disk. Similarity solutions obtained in our previous study are utilized to solve the particle transport equation. The particles are approximated to be in a polydisperse state that satisfies a lognormal size distribution. A moment model is used in order to predict distributions of particle number density and size simultaneously. Deposition of the particles on the disk is examined considering convection, Brownian diffusion, thermophoresis, and coagulation with variations of the forced flow velocity and the disk rotating velocity. The deposition rate and the efficiency directly increase as the flow velocity increases, resulting from that the increase of the forced flow velocity causes thinner thermal and diffusion boundary layer thicknesses and thus causes the increase of thermophoretic drift and Brownian diffusion of the particles toward the disk. However, the increase of the disk rotating speed does not result in the direct increase of the deposition rate and the deposition efficiency. Slower flow velocity causes extension of the time scale for coagulation and thus yields larger mean particle size and its geometric standard deviation at the deposition surface. In the case of coagulation starting farther from the deposition surface, coagulation effects increases, resulting in the increase of the particle size and the decrease of the deposition rate at the surface.

착용형 관성센서 및 인체 하지부 기구학 기반의 보행자 속도추정에 관한 연구 (Pedestrian Walking Velocity Estimation based on Wearable Inertial Sensors and Lower-limb Kinematics)

  • 김명규;김종경;이동훈
    • 대한기계학회논문집A
    • /
    • 제41권9호
    • /
    • pp.799-807
    • /
    • 2017
  • 본 논문은 하지부의 각 분절에 부착된 착용형 관성센서의 자세 및 각속도 정보와 하지부 기구학을 기반으로 착용자의 보행속도를 추정하는 방법에 관한 연구를 다룬다. 보행 주기 중 발바닥과 지면이 완전히 접촉되지 않는 구간에서는 골반부에 장착된 관성센서의 가속도 출력을 적분하여 보행속도를 추정할 수 있다. 이 때, 보행 시 골반부의 기울어짐으로 인하여 발생되는 가속도의 측정오차의 누적 영향을 최소화하기 위하여, 하지부 기구학을 기반으로 추정된 보행속도를 매 보행 주기마다 골반 관성센서의 가속도 출력신호 적분 초기값으로 갱신한다. 그 결과 6분 가량의 야외 보행 실험을 수행한 결과, 오차 누적에 의한 영향은 관찰되지 않았으며, 보행속도 추정 오차의 RMS는 0.08m/s 이하인 것으로 확인되었다.

코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.