• Title/Summary/Keyword: Drawn-on-film

Search Result 88, Processing Time 0.023 seconds

A study on convergence of 2D and 3D animation : Focused on character and expression technique (2D 애니메이션과 3D 애니메이션의 융합: 캐릭터와 제작 기법을 중심으로)

  • Kim, Min-Jung;Kwak, No-Jun
    • Cartoon and Animation Studies
    • /
    • s.48
    • /
    • pp.45-67
    • /
    • 2017
  • Many of the modern animations have 3D technology, and as time goes by, their production technology becomes more diverse and sophisticated. When John Alan Lasseter insisted on studying CG animation technology, he might have taken our jobs to the computer in the near future, as many people were worried about. It may be premature to worry that an unstable future may become a reality at this point, but I do not think there will be any difference in the fact that many animations are being produced using 3D technology. Since the Toy Story was screened in 1995, the 3D animation production technology has started to develop rapidly and now it has been elaborately developed so that it can not distinguish the part where computer graphics technology is applied from the live film. On the other hand, Disney's 2D animation part falls into the decline path because the appearance of 3D animation was perceived as a new expression technique at that time, and the efficiency of the work process was superior to the 2D animation in addition to receiving the attention from the audience. Is it necessary to accept the retrogression of 2D animation technology, reflecting the environment of the animation industry that 3D animation production technology has become mainstream in the first 20 years since the first theatrical works appeared? Since 2D animation technology has a long history and is still attractive to the audience, it is not hard to find an attempt to combine 2D and 3D animation technology. In this paper, I want to study 2D hand - drawn character in 3D animation. Through this, it is hoped that animation convergence technology will be applied more actively in the future.

Study on Image of Femme Fatale represented on Costumes in the Movie 'Chicago' (영화 '시카고'의 의상(衣裳)에 나타난 팜므 파탈 이미지 연구(硏究))

  • Kim, Ji-Young;Kan, Ho-sup
    • Journal of Fashion Business
    • /
    • v.8 no.1
    • /
    • pp.16-33
    • /
    • 2004
  • Up to now, image of femme fatale has undergone constant transformation to be inherited and developed through various genres of movies. With few exceptions such cases have represented sensuality of women by costumes with the most distinctive and exaggerated sexuality. Temptresses in movies are mostly drawn as extravagant and gorgeous one or a gloomy and dreary woman. Such an image is reinforced with make-up, hair style, accessories, attitude and manner of talking. The movie 'Chicago' is a musical film that crosses the boundaries of reality and fantasy with dancing and singing. Its lighting, stage setting, powerful and sexy dancing augmented already exaggerated and sensual costumes. Following is the analysis of costumes for two heroines as images of femme fatale. Strong contrast of color among black, red and blue on see-through & stickingly tight body suit signifies liberal mind and arrogant charisma of Velma. The contrast, haughty gestures, cropped black hair and thick makeups represent sex appeal, aggressive image, and fearlessly determined character of femme fatale. Roxie wears decent dresses in front of public and gorgeous stage costume in fantasy to convey two images of bad girl and angel. Her body suit, showing off lustering materials and dazzling bead decoration, is rather loose but still displays her bodyline to emphasize sexiness for representation of desire in fantasy. Chastity and innocence are implied with the decency of dresses in reality. They were specially chosen to draw public sympathy and indicate cunning disguise of Roxy who desperately wants to realize her desire. These dauntless costumes, which sufficiently express inside aspirations of Velma and Roxie later denote open and realistic social yearning rather than fatal desire hidden behind sensual beauty. It doesn't exist as imperfect, unrealistic and socially disdainful ambition as the image of femme fatale of paintings and movies did before in history. Femme fatale is expressed with deep cleavage, silk dresses that explicitly display bodyline, sexiness of mesh stockings with garter belts. All of these won't be utilized as a negative tool to seduce and destroy someone anymore but rather, they should represent rightful and fair nature of humans such as men's curiosity who secretly steal a look at them or female sexuality that women spontaneously want to show off.

Evaluation of Electron Boost Fields based on Surgical Clips and Operative Scars in Definitive Breast Irradiation (유방보존술 후 방사선치료에서 수술 흉터와 삽입된 클립을 이용한 전자설 추가 방사선 조사야 평가)

  • Lee, Re-Na;Chung, Eun-Ah;Lee, Ji-Hye;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.236-242
    • /
    • 2005
  • Purpose: To evaluate the role of surgical clips and scars in determining electron boost field for early stage breast cancer undergoing conserving surgery and postoperative radiotherapy and to provide an optimal method in drawing the boost field. Materials and Methods: Twenty patients who had $4{\sim}7$ surgical clips in the excision cavity were selected for this study. The depth informations were obtained to determine electron energy by measuring the distance from the skin to chest wall (SCD) and to the clip implanted in the most posterior area of tumor bed. Three different electron fields were outlined on a simulation film. The radiological tumor bed was determined by connecting all the clips implanted during surgery Clinical field (CF) was drawn by adding 3 cm margin around surgical scar. Surgical field (SF) was drawn by adding 2 cm margin around surgical clips and an Ideal field (IF) was outlined by adding 2 cm margin around both scar and clips. These fields were digitized into our planning system to measure the area of each separate field. The areas of the three different electron boost fields were compared. Finally, surgical clips were contoured on axial CT images and dose volume histogram was plotted to investigate 3-dimensional coverage of the clips. Results : The average depth difference between SCD and the maximal clip location was $0.7{\pm}0.55cm$. Greater difference of 5 mm or more was seen in 12 patients. The average shift between the borders of scar and clips were 1.7 1.2, 1.2, and 0.9 cm in superior, inferior, medial, and lateral directions, respectively. The area of the CF was larger than SF and IF in 6y20 patients. In 15/20 patients, the area difference between SF and if was less than 5%. One to three clips were seen outside the CF in 15/20 patients. In addition, dosimetrically inadequate coverage of clips (less than 80% of prescribed dose) were observed in 17/20 patients when CF was used as the boost field. Conclusion: The electron field determined from clinical scar underestimates the tumor bed in superior-inferior direction significantly and thereby underdosing the tissue at risk. The electron field obtained from surgical clips alone dose not cover the entire scar properly As a consequence, our technique, which combines the surgical clips and clinical scars in determining electron boost field, was proved to be effective in minimizing the geographical miss as well as normal tissue complications.

Expression Factors of Pace and Dynamics in Drawing Animation - Focused on Japanese Hero TV Animation Series - (드로잉 애니메이션에서 속도감과 역동성의 표현 요소 연구 - 일본 초인물 TV 애니메이션 중심으로-)

  • Kim, Hyun-Woo;Kim, Jae-Woong
    • Cartoon and Animation Studies
    • /
    • s.40
    • /
    • pp.109-137
    • /
    • 2015
  • As Digital technology developed, drawing animation, using traditional production method which expresses many feelings with drawn lines loses the youth group, the primary audience, to the realism of the digital cinema. Drawing animation, which drew attention of the youth by the spectacles in the film such as hectic pace, dynamics and punch, declined for a while. However, it has been developed a way to express pace and dynamics of its own by establishing an effective directing method, which combines digital technology as it is needed. This study has a purpose to investigate what causes the dynamics and feeling of fast movement of the character in Japanese limited animation. Though some action-animated films that heroes with supernatural powers take the leading role that feeling of velocity and dynamics are emphasized we compare the directing method before and after the introduction of the digital technology. This research reaches the conclusion by factoring each Bergson and McLuhan's discussion to the intervention of indexical signs and the audience's participation according to skipping technique. This study has a significance of researching the element of drawing animation that maximizes the expansion of the senses by defying the limitation of the law of physics through its unique way of directing together with growth of the hero films, which will continue.

Comparison of Monitor Units Obtained from Measurements and ADAC Planning System for High Energy Electrons (측정과 ADAC 치료계획 시스템에서 계산된 고에너지 전자선의 Monitor Unit Value 비교)

  • Lee, Re-Na;Choi, Jin-Ho;Suh, Hyun-Suk
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.202-208
    • /
    • 2002
  • The purpose of this study is to evaluate the monitor unit obtained from various methods for the treatment of superficial cancers using electron beams. Thirty-three breast cancer patients who were treated in our institution with 6, 9, and 12 MeV electron beams, were selected for this study. For each patient, irregularly shaped treatment blocks were drawn on simulation film and constructed. Using the irregular blocks, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and three-dimensional radiation treatment planning (3D RTP) system (PINNACLE 6.0, ADAC Laboratories, Milpitas CA) Measurements were made in solid water phantom with plane parallel (PP) chamber (Roos, OTW Germany) at 100 cm source-to surface distances. CT data was used to investigate the effect of heterogeneity. Monitor units were calculated by overriding CT values with 1 g/㎤ and in the presence of heterogeneity. The monitor unit values obtained by the above methods were compared. The dose, obtained from measurement in solid water phantom was higher than that of RTP values for irregularly shaped blocks. The maximum differences between monitor unit calculated in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. When CT data was used at a various gantry angle the agreement between the TPS data with and without density correction was within 3% for all energies. These results indicate that there are no significant difference in terms of monitor unit when density is corrected for the treatment of breast cancer patients with electrons.

  • PDF

A Study on the Dépaysement of the Animation (애니메이션에 있어서 데페이즈망에 관한 연구)

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.