• Title/Summary/Keyword: Drainage pump station operation

Search Result 8, Processing Time 0.02 seconds

A Study on Real-Time Operation Method of Urban Drainage System using Data-Driven Estimation (실시간 자료지향형 예측을 활용한 내배수 시설 운영기법 연구)

  • Son, Ahlong;Kim, Byunghyun;Han, Kunyeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.949-963
    • /
    • 2017
  • This study present an efficient way of operating drainage pump station as part of nonstructural measures for reducing urban flood damage. The water level in the drainage pump station was forecast using Neuro-Fuzzy and then operation rule of the drainage pump station was determined applying the genetic algorithm method based on the predicted inner water level. In order to reflect the topographical characteristics of the drainage area when constructing the Neuro-Fuzzy model, the model considering spatial parameters was developed. Also, the model was applied a penalty type of genetic algorithm so as to prevent repeated stops and operations while lowering my highest water level. The applicability of the development model for the five drainage pump stations in the Mapo drainage area was verified. It is considered to be able to effectively manage urban drainage facilities in the development of these operating rules.

Evaluation of Drain Pump System by Inundation Analysis in Urban Underground Passage (도시 지하차도 침수 분석을 통한 강제배제시설 평가)

  • Lee, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1192-1200
    • /
    • 2007
  • A general rainfall outflow in urban drainage has early time of concentration because urban drainage areas are most paved area. In general, rainfall outflow is flowed in drainage pump station and is discharged to rivers in urban areas. However it is excluded through drainage pumps about a heavy rainfall which exceed the design rainfall and the rainfall outflows increase the urban inundation risk. A current pump operation is control according to water level of collecting well or reservoir in drain pump station. But recently, the localized downpours are happened frequently in urban drainage and the current pump stations are frequently incapable of the heavy rainfall outflows. In this study, a real urban inundation was simulated and the drain capacity of drain pump station was evaluated by analysis about flood-factor in urban underground passage. Then the analysis about the inundation was done by the simulation about the real rainfall which cause the inundation. Also, in the simulation the inundation risk and the evaluation of flood-factor were analyzed according to change of the pump operation rule.

  • PDF

A Study of the Automatic Operation Performance of a Pump Station using Resilience Considering Residual Flows (잔류유량 기반 복원력 지수를 통한 빗물펌프장 자동운영 성능 검토)

  • Kim, Young Nam;Lee, Eui Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.793-802
    • /
    • 2022
  • Non-structural improvements to urban drainage systems are necessary to overcome the elevated levels of urban flood damage. This study proposed a type of automatic pump/gate operation technology for urban pump stations that takes reservoir inflows and river water levels into account and its performance is compared with the current operation using the concept of residual flow-based resilience. The proposed automatic operation relies on three pump operations and two gate operations. The water depth at the monitoring node was used for the pump operation, and the monitoring node was selected in consideration of the first overflow node and the maximum overflow node. The target area is the Daegu Bisan urban pump station, and the rainfall data consisted of probability rainfall sets with durations of 30 minutes, 60 minutes, 90 minutes and 120 minutes, and frequencies of 30, 50, and 70 years. As a result of the application of the proposed operation, differences in the resilience between the automatic operation and the current operation were at least 5.20E-05 with a maximum of 8.07E-04. The longer the duration is, the greater the difference in the resilience.

Development of a Pump Operation Rule in a Drainage Pump Station using a Real Time Control Model for Urban Drainage System (내배수시스템 실시간 운영 모형을 이용한 배수펌프장 운영기법 개발)

  • Lee, Jung-Ho;Lee, Yang-Jae;Kim, Joong-Hoon;Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.11
    • /
    • pp.877-886
    • /
    • 2007
  • An urban drainage system consists of two major systems : flood drainage facilities and operating practices. The facilities are composed of sewer networks, gates, and pumping stations and the operating practice consists of pump or gate operation. Then, a real time simulation system which is able to simulate urban runoff and the pump operation and to consider the backwater effect is required to operate efficiently the pump. With this system, the efficient pump operating rule can be developed to diminish the possible flood damage on urban areas. In this study, a real time simulation system was developed using the SWMM 5.0 DLL and Visual Basic 6.0 equipped with EXCEL. Also, for developing efficient pump operating Rules, two new Rules were suggested. The first Rule is designed to operate pumps considering the condition of sewer networks such as depths of each junction. The second is to discharge all the amount of inflow at each time step. Results obtained by those Rules were compared with one by the current pump operating Rule which is able to consider only the depth of the retard basin. The developed model was applied to Joonggok retard basin and verified their applicability.

Application of the Fuzzy Models for the Efficient Operation of Pumping Station (배수펌프장의 효율적인 운영을 위한 퍼지모형의 적용)

  • Kim, Yun-Tae;Shim, Jae-Hyun;Chung, Jae-Hak;Ahn, Jae-Chan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.51-60
    • /
    • 2004
  • Urban flood damage has been caused by drainage deficiency. One of the methods to solve this problem is to construct detention basin and Pumping station and to pump out the water to the river. However, because of rapid urbanization, the capacity of drainage pipelines is sometimes not sufficient enough during the rainy season. Therefore, even though we have enough pumping stations, the inflow of surface water never reaches to the detention area, causing floods in urban area. This research is to find improvement of urban drainage system, estimating drainage pipeline risk. Also, eight models for a computer program were developed for practical use. The models were verified changing precipitation duration, intensity, design period, time distribution model, and etc. This verification was processed focusing that the model can regulate the water level in the detention basin and minimize the effect downstream. As a result Fuzzy models were found to be efficient to lower the water level in detention basin, and decreased about 8 cm in water level of downstream.

A New Control Technique of Drainage Pump Based on Fuzzy Control (퍼지제어기법을 사용한 우수배제 펌프의 조작기법 개발)

  • Lee, Won Hwan;Cho, Won Cheol;Shim, Jae Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.107-114
    • /
    • 1992
  • With the increasing of impervious area and shortening of travel time, the risk of flooding in urban area becomes a serious problem in Seoul metropolitan area, and its alternatives are needed. In this study, one of urban flood alternatives, a fuzzy control technique is applied in pumping station to test its drainage capacity of inland inflow, and compared with existing pumping criteria (controled by water level). Three design rainfalls(10, 30, and 50 year) are applied to ILLUDAS model to calculate inflow in detention reservoir. To check the efficiency of fuzzy control, two fuzzy rules are used in the operation of pumping station. In these results, fuzzy control rules, based on the experiences of experts, show applicability in practice and effectiveness in inland flooding prevention.

  • PDF

Combined Inland-River Operation Technique for Reducing Inundation in Urban Area: The Case of Mokgam Drainage Watershed (도시지역의 침수저감을 위한 내외수 연계 운영 기법 개발: 목감천 유역을 중심으로)

  • Kwon, Soon Ho;Jung, Hyun Woo;Hwang, Yoon Kwon;Lee, Eui Hoon;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.257-266
    • /
    • 2021
  • Urban areas can often suffer flood damage because of the more frequent catastrophic rainfall events from climate change. Flood mitigation measures consist of (1) structural and (2) non-structural measures. In this study, the proposed method focused on operating an urban drainage system among non-structural measures. The combined inland-river operation technique estimates the inflow of pump stations based on the water level obtained from a preselected monitoring point, and the pump station expels the stored rainwater to the riverside based on those estimates. In this study, the proposed method was applied to the Mokgam drainage watershed, where catastrophic rainfall events occurred (i.e., 2010- and 2011-years), and severe flood damage was recorded in Seoul. Using the proposed method, the efficiency of flood reduction from the two rainfall events was reduced by 34.9 % and 54.4 %, respectively, compared to the current operation method. Thus, the proposed method can minimize the flood damage in the Mokgam drainage watershed by reserving the additional storage space of a reservoir. In addition, flooding from catastrophic rainfall can be prevented, and citizens' lives and property in urban areas can be protected.

The Study of the Decision Criteria for the Urgency Released Valve in Hydraulic Dam (수력댐 비상방류밸브의 선정조건에 관한 연구)

  • Roh, H.W.;Lee, G.S.;Park, Y.M.;Kim, B.S.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.613-616
    • /
    • 2005
  • In general, the hollow jet valve, the fixed cone valve had been used for the urgency released or maintenance of the flow rate. Nowadays, the butterfly valve, the gate valve are applied in economic performance and operation maintenance more than the hollow jet valve, the fixed cone valve. However, in the case of butterfly valve, it should be required the strict application standard to the cavitation coefficient because the structural axis and disk were situated in pipe channel and the occurring the shock problem by Karman Vortex. And, the judgment data for choice were slight lowdown in water supply and drainage facilities standard or Japanese penstock technology standard, various standard of KOWACO etc. Therefore. there were investigated the valve inside phenomenon (cavitation, disk chattering, vibration) by velocity of flow and the stability examination of body by high velocity of flow through flow scale model test using the numerical analysis and PIV to establish the applicable extensibility of the butterfly valve for the urgency released valve.

  • PDF