• Title/Summary/Keyword: Drainage noise

Search Result 39, Processing Time 0.026 seconds

A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing (대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구)

  • Soul, Soo-Hwan;Jung, Chul-Woon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.

A Study on the Structure-borne Noise and Noise Reduction of Drainage Pipes (배수관의 구조소음과 소음저감에 관한 연구)

  • Ryu, B.J.;Lee, G.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.194-202
    • /
    • 2009
  • The paper deals with the countermeasure against structure-borne noise source and noise reduction of drainage pipes. Recently, the problem the problem of the toilet drain noise of an apartment house has been become the center of public interest and a target of public grievance. Generally, the drain noise of a toilet in the apartment house has a pink noise characteristics below 2 kHz level, and therefore, the structure-borne noise has a great effect on the entire drain noise. In order to measure the transmission loss for various kinds of pipes such as PVC pipes, cast-iron pipes and newly developed AS pipes, experimental setup containing speakers as a sound source was designed and manufactured. The second-stories measurement room with a small size anechoic chamber was constructed and the noise level for different kinds of drainage pipes was measured by the sound level meter. Through the experimental research in the study, noise reduction capacity for various kinds of drainage pipes and countermeasures against structure-borne noise source are demonstrated.

  • PDF

A Study on reduction of drainage noise for water closet (공동주택 변기 배수소음 저감 방안에 관한 연구)

  • 김인수;고철수;문재호;한문성;심경석;이준서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.881-885
    • /
    • 2001
  • The study about a drainpipe of water closet was performed as reduction of drainage noise for water closet. The Drainage noise is composed two characteristics. One is Low frequency noise and the other is high frequency noise. Low frequency noise is dominant in the first stage and high frequency noise is dominant in the last stage. This is due to water splashing and that is caused by formation of chamber pot. In this experiment, for the purpose for reducing the noise, we choose the hollow rubber pipe element. As a result, we reduced drainage noise about 11㏈A.

  • PDF

Characteristics of Reducing the Water-drainage Noise of Toilet-bowl According to the Composition of Water Drainage Piping Materials of the Bathrooms of Apartment Housing (공동주택 욕실 배수배관 자재 구성에 따른 양변기 배수소음 저감 특성)

  • Jeong, A-Yeong;Kim, Kyoung-woo;Shin, Hye-kyung;Yang, Kwan-seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2017
  • Water supply and drainage noise in the bathroom is recognized as one of the main noises, along with the floor-impact sounds, in apartment housings. Recently, to solve such noise issues, a new construction method of installing the piping on the slab has been adopted. rather than the traditional method of penetrating the piping through the slab between the upper and the lower bathrooms. However, this new method has limitations due to high costs and constructional difficulties. Therefore, this study was conducted to develop noise reducing piping and elbows, where the noise can be reduced simply by replacing the existing pipings. The noise level was measured in a laboratory by installing the horizontal drainage piping (three types) and the elbows (three types) developed in this study. The results showed that the horizontal pipings reduced the noise level in LAmax by 0.3 dB(A)~1.0 dB(A), as compared to the existing pipings (VG2), indicating an insignificant noise reduction effect. The elbow reduced the noise level in LAmax by 5.5 dB(A) ~ 11.5 dB(A), as compared to the existing elbow (DRF elbow), with the result of reducing the noise level at all frequencies evenly. Consequently, it was shown that using the elbows is more effective in reducing the water-drainage noise from the toilet than using the horizontal pipings.

A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials (복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

Criteria for multiple noises in residential buildings uslng combined rating system (공동주택 생활소음의 통합 평가등급 설정)

  • Ryu, Jong-Kwan;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.367-371
    • /
    • 2005
  • Social noise survey on multiple residential noises such as nut impact, air-borne, bathroom, drainage and traffic noises was conducted to investigate major variables affecting the overall satisfaction for noise environment The effect of individual noise perception on the evaluation of the overall noise environment was investigated through a questionnaire survey on annoyance, disturbance and noise sensitivity. Auditory experiments was also undertaken to determine noise level according to the percent of satisfaction for individual noise source. As a result of survey, it was found that satisfaction for floor impact noise most greatly affects the overall satisfaction for noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Result of auditory experiment showed that the noise level of floor impact noise by bang machine, airborne, drainage and traffic noise corresponding to 50% satisfaction is 44dB($L_{i,Fmax,AW}$) and 40dBA, respectively.

  • PDF

Classification of Noise Insulation Performance in Apartment Buildings through Noise survey and Auditory Experiment (설문조사와 청감실험을 통한 공동주택 차음성능의 평가등급 설정)

  • Ryu, Jong-Kwan;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.666-669
    • /
    • 2005
  • Social noise survey and auditory experiment on residential noises such as floor impact, air-borne, bathroom, drainage and traffic noises were conducted to classily a noise insulation Performance in apartment building. The survey results showed that annoyance among subjective responses to residential noises was most greatly affecting to satisfaction with noises. In the survey, boundary limit between satisfaction and dissatisfaction was also determined. Auditory experiments was also undertaken to determine noise insulation performance according to the percent of satisfaction for individual noise source. Result of auditory experiment showed that the noise insulation performance for floor impact, airborne, drainage and traffic noise corresponding to 40 % satisfaction is 49 dB (L$_{i,Fmax,AW}$), 48 dB (R'w), N-41, and N-40, respectively. Finally, classes of noise insulation performance in apartment building were proposed according to satisfaction with noises

  • PDF

Subjective Evaluation of Drainage Noise in Bathroom of Apartment Buildings (공동주택 욕실 배수소음의 주관적 평가)

  • 장호연;류종관;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.766-771
    • /
    • 2003
  • In this study the drainage noises were investigated for the subjective allowing limitation and the testified classes. 7 point scale was selected to evaluate the annoyance level with vocabularies. As a result, 'a little annoying' is the most suitable expression for the allowing limitation, and the sound pressure levels for the urinal was 43.5㏈ and the bathtub was 44.6㏈.

  • PDF

A Study on the Residents' Attitudes and Adaptation Behavior of Indoor Noise in Apartment Houses (아파트 내부소음에 대한 거주자 태도 및 적응행위에 관한 연구)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.85-96
    • /
    • 1989
  • The purpose of study was to survey the indoor noise of apartment houses, residents, attitudes and their adaptation behavior in order to offer the information helpful to apartment designers and residents, in their housing policy. Documentary research and questionnaire survey methods were used in this research. The sample was taken from 187 housewives living in apartments in Seoul. Data were analyzed with the SPSS program. The results were as follow : 1. It was found that apartment residents pointed out washing machine noise inside the home, piano and other musical instruments noise outside the home. 2. Piano and other musical instrument noise were heard at 3 to 6 pp.m. when residents heard the noise, and water supply and drainage noise in bathrooms were found most noisy. 3. Apartment residents were discontent with noise outside the home, and they displayed positive adaptation behavior at a reduced noise level. 4. Attitudes arising from indoor noise in apartment houses and human noise, water supply and drainage noise, doorway opening and closing noise were found to be significant in sampled apartment groups. 5. The youngest child's age was a significant variable on the residents' attitudes and adaptation behavior of indoor noise in apartment houses. 6. Between the resident' attitudes and adaptation behavior involving indoor noise in apartment houses. 6. Between the resident' attitueds and adaptation behavior involving indoor noise apartment houses, the more they became discontented, the more quickly they adapted in a postive manner.

  • PDF