• 제목/요약/키워드: Drainage flow

검색결과 510건 처리시간 0.027초

관재료 및 피복재료별 농경지 암거배수 효과 분석 (Analyses of subsurface drainage effects of farmland with respect to pipe and envelop material)

  • 정상옥
    • 한국농공학회지
    • /
    • 제37권5호
    • /
    • pp.53-61
    • /
    • 1995
  • Analyses of subsurface drainage effects of farmland with respect to pipe and envelop material are made by the laboratory experiments using soil box to give basic information for the subsurface drainage system planning and design. Three different diameter PVC perforated pipes and a mesh pipe are used with envelop materials such as sand, rice bran, and crushed stone. Steady state subsurface drainage flow rate increased as envelop material changed from sand to rice bran and crushed stone. This indicates that as the hydraulic conductivity of the envelop material increases, the drainage flow rate increases. On the other hand, for a given envelop material, the mesh pipe which has the largest openning area shows the largest flow rate while small diameter PVC pipes show small flow rates. This tells that as the openning area and pipe diameter increase, the flow rate increases, too. Therefore, selection of pipe and envelop material should be made in accordance with the design drainage flow rate. Unsteady state subsurface drainage flow rate with respect to time differs for different envelop material. In case the sand was used as an envelop material, the small diameter PVC pipes show larger flow rates than the large diameter PVC pipe and mesh pipe. When the rice bran was used, the mesh pipe shows the largest flow rate, while small diameter pipes show smaller flow rates. In case the crushed stone was used as an envelop material, the large diameter PVC pipe and mesh pipe show larger flow rates, while small diameter pipes show a little bit smaller flow rates. However, the variation of flow rates among different pipes is the smallest when the crushed stone is used. The flow rate curve with respect to the pipe changes little for the crushed stone envelop which has a large hydraulic conductivity, while that changes much for the sand and rice bran envelops. However, it is difficult to draw a consistent relationship between the drainage flow rate and pipe for all the envelop materials. Since the subsurface drainage experiments are made only under the restricted laboratory condition in this study, further study including field experiment is required.

  • PDF

부압을 이용한 배수시스템의 비정상상태 유동특성해석 (Study on the unsteady characteristics of depressurized drainage system)

  • 이길석;이진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2682-2687
    • /
    • 2008
  • Depressurized drainage systems have been used for more than 30 years and are becoming a common part of urban drainage infrastructures. The hydraulic principles governing the operation of the depressurized drainage systems were studied in this paper and particularly, focused on the analysis of unsteady characteristics of the two-phase flow. A definition of the filling ratio was outlined and types of flow pattern were classified according to the filling ratio. Experiments were conducted to investigate the main features of pressure fluctuation. All results were found to depend on the filling ratio of the upstream pipe flow as well as the upstream Froude number.

  • PDF

시험시공을 통한 일방향 배수필터의 성능 평가 (Evaluation of the Performance of One-way Drainage Filter by Field Test)

  • 서동욱;김현태
    • 한국농공학회논문집
    • /
    • 제54권4호
    • /
    • pp.47-53
    • /
    • 2012
  • It is needed to install a one-way drainage filter to prevent a seepage from lake or river outside of embankment and to promote a drainage from a flood inside of embankment when dikes such as lake dike, river dike, etc are constructed. However, the results of research for one-way drainage filter are insufficient. Therefore, through the field test of one-way drainage filter, this study checked a function of one-way drainage filter with a test of performance. As a result of field test, water flow in dike was blocked in the interception direction of the section that one-way drainage filter was installed, but water passed to the flow allowance direction of the section. Therefore we confirmed the function of one-way drainage filter. Seepage quantity in the flow allowance direction of the one-way drainage filter section was low as 74.6~80.5 % than that in the section without installation of filter because of a reduction effect of seepage with filter. And seepage quantity of field test was low as 64.3~90.0 % than that in results of seepage analysis because the coefficient of permeability of embankment in field is different from the results of laboratory test. In the future, more study will be needed to solve several problems which are related to fix the filter on slide, durability of filter, etc.

논 지구의 배수로 부정류 흐름 모의를 위한 모델링 시스템 (Modeling System for Unsteady Flow Simulations in Drainage Channel Networks of Paddy Field Districts)

  • 강민구
    • 한국농공학회논문집
    • /
    • 제56권2호
    • /
    • pp.1-9
    • /
    • 2014
  • A modeling system is constructed by integrating an one-dimensional unsteady flow simulation model and a hydrologic model to simulate flood flows in drainage channel networks of paddy field districts. The modeling system's applicability is validated by simulating flood discharges from a paddy field district, which consists of nine paddy fields and one drainage channel. The simulation results are in good agreement with the observed. Particularly, in the verification stage, the relative errors of peak flows and peak depths between the observed and simulated hydrographs range 8.96 to 10.26 % and -10.26 to 2.97 %, respectively. The modeling system's capability is compared with that of a water balance equation-based model; it is revealed that the modeling system's accuracy is superior to the other model. In addition, the simulations of flood discharges from large-sized paddy fields through drainage channels show that the flood discharge patterns are affected by drainage outlet management for paddy fields and physical characteristics of the drainage channels. Finally, it is concluded that to efficiently design drainage channel networks, it is necessary to analyze the results from simulating flood discharges of the drainage channel networks according to their physical characteristics and connectivities.

배수갑문 물받이의 수리현상에 관한 연구 (A Study on the Hydroulic Phenomenon at the Douvstream Channel of the Drainage Sluice)

  • 이희영
    • 한국농공학회지
    • /
    • 제18권4호
    • /
    • pp.4218-4225
    • /
    • 1976
  • To insure the safety of the drainage sluice, topogrophical change due to erosion as well as capability of discharging the design flow in a very important factor. In consideration of the fact that the drainage sluice is built in the sea, its construction has many topographically restricted problems and naturally requires a completeness of research and experiment. This thesis is a comparative and analytic study of discharging flow acting on the erosion at the bottom of the structure on the basis of the measured velocity on the downstream channel of the drainage sluice. (1) The measured velocity shows a little higher values than the computed velocity, because the measured velocity was observed at the surface of the stream. There fore, it is reasonable that the compated velocity should be taken in this study. (2) The field observation was conducted to have the measurement of the flow velocity without surveying the area of flow. Therefore, the coefficient of discharge could not be computed. The survey of the area of flow is planned to be conducted along with the measurement of the flow velocity. (3) The apron of the drainage sluice is free discharging type and it was designed to be about 80m in length less than it should be. (4) The apron of free flow discharging type should have a solid foundation to protect the structure by preventing erosion damage to upstream and downstream channels against weathering of rock and strong torrent. Whether free flow discharging type or energy-dissipating type is best chosen depends on the topographical condition of the forage site, therefore, there would be a comparative study before the final decision was made about the protrection for the structure. (5) It is considered to be appropriate that the design and construction of the drainage sluice should have a complete study which is based on hydraulie model test before the type of protection is decided. (6) It is much requested that a variety of experiment equipments be installed and observed to study the protection for the drainage sluice.

  • PDF

우리나라 하수도시설의 첨두부하율 영향요소 분석 (Analysis of Factors Affecting Peak Loading Coefficient of Sewer Works in Korea)

  • 현인환;이영호
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.877-884
    • /
    • 2011
  • Although peak loading coefficient is one of critical design factors for sewer works, its detailed affecting factors were not analyzed because of limited data availability. This study analyzed the affecting factors on peak loading coefficient with plenty data obtained from several newly constructed sewer works. Simple and multiple regression analysis methods were adopted to analyze the relationships of each variable with or without data filtering. Drainage population, drainage area, population density, and daily sewage flow per person showed very weak relationships under diverse characteristics of cities. However, daily sewage flow per person showed stronger relationships with peak loading when daily sewage flow per person was splitted into two ranges. Population density (i.e., drainage population divided by drainage area) and daily sewage flow per person considerably were related with peak loading coefficient when daily sewage flow per person is less than about 400 Lpcd.

구배가 없는 신배수시스템의 제안 및 배수유동 특성에 관한 실험적 연구 (The Proposal of a New Drainage System without Incline of Piping and Experiment on Drainage Flow Characteristics)

  • 차영호;이정재
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.452-458
    • /
    • 2005
  • In Korea, pumping pipe using gravity way by water is most popular method in drainage system. But, it is difficult to repair a drainpipe in this method because the drain pipe diameter is increased as using this method. In this research, we propose a new drainage system. The system aim for an adaptedness with buildings, freedom of plan, construction and renewal in water pipe equipments, etc. The new system is not need of incline of piping, and it uses drainage power that is changed potential energy by high velocity flow as making Siphonage at vertical pipe. Therefore, the diameter of piping can decreased than existing piping system established in the ceiling. Also because connecting position will be located at the lower part, it is changed the potential energy of drainage to the high velocity flow. In addition, drainage will be smooth because the fixture drain is linked by each drain pipes.

수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구 (An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube)

  • 설신수;이상용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

침수방지와 방충.방취 기능을 갖는 오우배수장치의 개발 (The Development of Sewer Drainage for Harmful Insect and Bad Smell Prevention)

  • 김용석;박성호;양순용
    • 한국공작기계학회논문집
    • /
    • 제17권3호
    • /
    • pp.94-100
    • /
    • 2008
  • New type of the sewer drainage has been developed to overcome present sewer drainage's shortcoming. This system has the function of drainage, sewerage, reverse flow prevention, and harmful insect and smell prevention. Numerical simulation has been carried out in order to minimize the troubles that can be happened in the process of manufacture and installation process. This sewer drainage system for harmful insect and smell prevention intercepts pollution source, and then it prohibit second pollution. Harmful insect cannot go in and out in this system. Also, this system can reduce the damage of flooded districts due to heavy rain because it is impossible to flow backward from sewer drainage.

부등류 해석을 기반으로 한 노면배수시설 설계 (Design of Road Surface Drainage Facilities Based on Varied Flow Analysis)

  • 구혜진;김진수;박형섭;전경수
    • 한국수자원학회논문집
    • /
    • 제41권12호
    • /
    • pp.1173-1185
    • /
    • 2008
  • 노면배수시설의 설계방법을 임계지속시간의 고려 여부와 등류 및 부등류의 해석 방법에 따라 4가지로 구분하고, 각 방법에 따른 설계결과를 비교·검토하였다. 임계지속시간을 고려하지 않는 방법에서 설계강우는 10분 지속시간의 강우강도로 정하나, 임계지속시간을 고려할 경우 설계강우는 강우의 지속시간과 유출의 도달시간이 유사해지는 경우를 시산적으로 찾아 결정한다. 4가지 설계방법으로 수립된 설계모형을 다양한 수로의 종단경사 및 길어깨 횡단경사를 가지는 노면배수시설에 적용하고, 그 설계결과를 비교 검토하였다. 10분 지속시간의 강우강도를 이용하는 경우, 부등류 해석을 기반으로 설계한 유출구 간격은 종단경사와 길어깨 횡단경사가 작은 경우에만 등류 해석보다 크게 산정되었다. 반면 도달시간을 산정하여 임계지속시간을 결정하는 경우에는 본 연구에서 고려된 모든 조건에서 부등류 해석을 기반으로 설계한 유출구 간격이 등류 해석보다 크게 산정되었다. 그러나 도달시간을 산정하여 임계지속시간을 결정하고 부등류 해석을 기반으로 설계한 유출구 간격은 10분 지속시간의 강우강도를 적용하고 등류 해석을 기반으로 설계한 값보다 항상 작은 것으로 조사되었다.