• Title/Summary/Keyword: Drain-route

Search Result 13, Processing Time 0.02 seconds

Route Selection Protocol based on Energy Drain Rates in Mobile Ad Hoc Networks (무선 Ad Hoc 통신망에서 에너지 소모율(Energy Drain Rate)에 기반한 경로선택 프로토콜)

  • Kim, Dong-Kyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7A
    • /
    • pp.451-466
    • /
    • 2003
  • Untethered nodes in mobile ad-hoc networks strongly depend on the efficient use of their batteries. In this paper, we propose a new metric, the drain rate, to forecast the lifetime of nodes according to current traffic conditions. This metric is combined with the value of the remaining battery capacity to determine which nodes can be part of an active route. We describe new route selection mechanisms for MANET routing protocols, which we call the Minimum Drain Rate (MDR) and the Conditional Minimum Drain Rate (CMDR). MDR extends nodal battery life and the duration of paths, while CMDR also minimizes the total transmission power consumed per packet. Using the ns-2 simulator and the dynamic source routing (DSR) protocol, we compare MDR and CMDR against prior proposals for power-aware routing and show that using the drain rate for power-aware route selection offers superior performance results.

Accuracy Analysis of RTK-GPS Rover Speed in Route Surveying (RTK-GPS에 의한 노선측량에서 이동국의 속도에 따른 정확도 분석)

  • 최병길;이형수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.139-144
    • /
    • 2004
  • This study aims to analyze the accuracy of rover speed change in route surveying using RTK-GPS. Route surveying methods using GPS contain Static, DGPS, and RTK-GPS. Much research of navigation system, positioning of vehicles by DGPS, and accuracy analysis by GPS surveying have already been done. From this study, it is firstly found that DGPS is suitable for car navigation and sea navigation with an error of meter scale but not good for detailed construction, designing maps and updating GIS databases. Secondly, RTK-GPS can be used for managing gas pipes, water supply and drain pipes and fiber-optic cable that are needed to be controlled in a real time basis. Thirdly, since the accuracies of route surveying by RTK-GPS and DGPS are not correctly matched with the change of rover speed, the choice of route surveying method from those two should follow the need of accuracy fidelity Further study should focus on Cycle Slip problem and coordinate change problem in tunnel and mountainous areas.

  • PDF

A Study of Environment-friendly outer wall facilities for the improvement of port pollution (항내오염 개선을 위한 친환경 외곽시설에 관한 연구)

  • 김강민;강석형;유하상;김상훈
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.165-170
    • /
    • 2003
  • Due to the impermeability of outer wall facilities such a Breakwaters which dissipates the wave energy and keeps harbor tranquility, the water exchange can be worse and increased enclosed at the harbor. Recent trends of port development protect water quality and emphasize Water-Front, so the method which enhances the circulation of harbor waters and the dilution of the water pollutants are studied. The best improvement of water quality is a remove of pollutant source on land, but an enclosed port must be enhanced the tidal exchange. To this hence, the best improvement may be made on drain-route on the existing outer wall facilities. In this study, the numerical computations were carried out to predict the circulation of harbor waters and the tidal exchange in the polluted harbor(Samchonpo-guhang) located at the east coast of South Sea. Computational models adopting FDM(Finite Difference Method) were used here and were already verified from the previous studies and ocean survey. As a result of this study, the tidal exchange in Samchonpo-guhang before and after installation of drain-route is assessed.

  • PDF

A Study on Environmentally Friend Counter Facilities for Improvement of Harbor Water Quality (항내수질 개선을 위한 친환경 외곽시설에 관한 연구)

  • Kim, Kang-Min;Kang, Suk-Hyong;Ryu, Ha-Sang;Kim, Sang-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.2
    • /
    • pp.233-238
    • /
    • 2003
  • Due to the impermeability of outer wall facilities such as Breakwaters which dissipates the wave energy and keeps harbor tranquility, the enclosed area of harbor becomes partially blocked and the water exchange can be reduced. Recent trends of port development protect water quality and emphasize Water-Front, so the method which enhances the circulation of harbor waters and the dilution of the water pollutants are studied. The best improvement of water quality is a remove of pollutant source on land, but an enclosed port must be enhanced the tidal exchange. For this end, the best improvement may be made a drain-route on the existing outer wall facilities. In this study, the numerical computations were carried out to predict the circulation of harbor waters and the tidal exchange through the drain-rout in the polluted harbor(Samchonpo-guhang) located at the east coast of South Sea. Computational models adopting FDM(Finite Difference Method) were used here and were already verified from the previous studies und ocean survey. As a result of this study, circulation and the tidal exchange at the harbor before and after introduction of drain-route were assessed.

Simple Route to High-performance and Solution-processed ZnO Thin Film Transistors Using Alkali Metal Doping

  • Kim, Yeon-Sang;Park, Si-Yun;Kim, Gyeong-Jun;Im, Geon-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.187-187
    • /
    • 2012
  • Solution-processed metal-alloy oxides such as indium zinc oxide (IZO), indium gallium zinc oxide (IGZO) has been extensively researched due to their high electron mobility, environmental stability, optical transparency, and solution-processibility. In spite of their excellent material properties, however, there remains a challenging problem for utilizing IZO or IGZO in electronic devices: the supply shortage of indium (In). The cost of indium is high, what is more, indium is becoming more expensive and scarce and thus strategically important. Therefore, developing an alternative route to improve carrier mobility of solution-processable ZnO is critical and essential. Here, we introduce a simple route to achieve high-performance and low-temperature solution-processed ZnO thin film transistors (TFTs) by employing alkali-metal doping such as Li, Na, K or Rb. Li-doped ZnO TFTs exhibited excellent device performance with a field-effect mobility of $7.3cm^2{\cdot}V-1{\cdot}s-1$ and an on/off current ratio of more than 107. Also, in case of higher drain voltage operation (VD=60V), the field effect mobility increased up to $11.45cm^2{\cdot}V-1{\cdot}s-1$. These all alkali metal doped ZnO TFTs were fabricated at maximum process temperature as low as $300^{\circ}C$. Moreover, low-voltage operating ZnO TFTs was fabricated with the ion gel gate dielectrics. The ultra high capacitance of the ion gel gate dielectrics allowed high on-current operation at low voltage. These devices also showed excellent operational stability.

  • PDF

Deleyed Cardiac Tamponade After Open Heart Surgery (Two Cases Report) (개심술후에 발생한 지연성 심장압진증)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.218-221
    • /
    • 1982
  • Delayed cardiac tamponade in an uncommon and frequently fatal complication after open-heart surgery. We had been experienced two cases of delayed cardiac tamponade as a complication of open-heart surgery and treated successfully by reinsertion of pericardial drain through subxiphoid route. First case was 60 years old female patient and underwent MVR under impression of MSi + Ti Second case was 19 years old male patient and underwent total correction of T.O.F.with Blalock shunt [Lt]. Both cases had Initial symptoms, which were epigastric pain, chest tightness, dropped blood pressure, and increased pulse rate and respiratory rate, mimic as low cardiac output syndrome after open-heart surgery. Roentgenogram of the chest showed a rapid increased cardiothoracic ratio. It is important to realize the presence of late cardiac tamponade for proper diagnosis of complication after open-heart surgery.

  • PDF

Effect of Perioperative Prophylactic Intravenous Antibiotic Use in Immediate Implant-Based Breast Reconstruction: A Retrospective Matched Cohort Study

  • Seok Kyung In;Seok Won Park;Yujin Myung
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.36-41
    • /
    • 2024
  • Background Among breast reconstruction methods, implant-based breast reconstruction has become the mainstream. However, periprosthetic infection is still an unresolved problem. Although published articles have revealed that limited use of antibiotics is sufficient to reduce infection rates, the number of surgeons still preferring elongated usage of antibiotics is not less. The aim of our study is to validate the appropriate duration of antibiotic use to reduce infection rate after implant-based breast reconstruction. Methods A retrospective study reviewed medical record of 235 patients (274 implants for reconstruction) who underwent prepectoral direct to implant breast reconstruction using acellular dermal matrix wrapping technique. Infection rates were analyzed for the patients administered postoperative prophylactic antibiotics until drain removal and those who received only perioperative prophylactic antibiotics for 24 hours. Results Of the 274 implants, 98 who were administered prophylactic antibiotics until drain removal had an infection rate of 3.06% (three implants) and 176 who received prophylactic antibiotics no longer than 24 hours postoperatively had an infection rate of 4.49% (eight implants). A total of 11 patients diagnosed with postoperative infection clinically, 8 were salvaged by antibiotic treatment, and 3 had implant removal and replacement with autologous flap. Postoperative antibiotic prophylaxis duration had no statistically significant effects in the risk of infection (p = 0.549). Conclusion The duration of prophylactic antibiotics after surgery was not related to infection risk. Further study with a large number of patients, randomized control study, and route of antibiotics is needed.

On demand nanowire device decalcomania

  • Lee, Tae-Il;Choi, Ji-Hyuck;Moon, Kyung-Ju;Jeon, Joo-Hee;Myoung, Jae-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.26.1-26.1
    • /
    • 2009
  • A simple route of external mechanical force is presented for enhancing the electrical properties of polymer nanocomposite consisted of nanowires. By dispersing ZnO nanowires in polymer solution and drop casting on substrates, nanocomposite transistors containing ZnO nanowires are successfully fabricated. Even though the ZnO nanowires density is properly controlled for device fabrication, as-cast device doesn't show any detectable currents, because nanowires are separated far from each other with the insulating polymer matrix intervening between them. Compared to the device pressed at 300 kPa, the device pressed at 600 kPa currents increased by 50times showing the linear behavior against drain voltage and exhibits promising electrical properties, which operates in the depletion mode with higher mobility and on-current. Such an improved device performance would be realized by the contacts improvement and the increase of the number of electrical path induced by external force. This approach provides a viable solution for serious contact resistance problem of nanocomposite materials and promises for future manufacturing of high-performance devices.

  • PDF

Press induced enhancement of contact resistance innanocomposite FET based on ZnO nanowire/polymer

  • Choe, Ji-Hyeok;Mun, Gyeong-Ju;Jeon, Ju-Hui;Kar, Jyoti Prakash;Das, Sachindra Nath;Gang, Dal-Yeong;Lee, Tae-Il;Myeong, Jae-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.26.2-26.2
    • /
    • 2009
  • A simple route of externalmechanical force is presented for enhancing the electrical properties ofpolymer nanocomposite consisted of nanowires. By dispersing ZnO nanowires inpolymer solution and drop casting on substrates, nanocomposite transistorscontaining ZnO nanowires are successfully fabricated. Even though the ZnOnanowires density is properly controlled for device fabrication, as-cast devicedoesn't show any detectablecurrents, because nanowires are separated far from each other with theinsulating polymer matrix intervening between them. Compared to the devicepressed at 300 kPa, the device pressed at 600 kPa currents increased by 50times showing the linear behavior against drain voltage and exhibits promisingelectrical properties, which operates in the depletion mode with highermobility and on-current. Such an improved device performance would be realizedby the contacts improvement and the increase of the number of electrical pathinduced by external force. This approach provides a viable solution for seriouscontact resistance problem of nanocomposite materials and promises for futuremanufacturing of high-performance devices.

  • PDF

Key Re-distribution Scheme of Dynamic Filtering Utilizing Attack Information for Improving Energy Efficiency in WSNs (무선 센서 네트워크에서 에너지 효율성 향상을 위해 공격정보를 활용한 동적 여과 기법의 키 재분배 기법)

  • Park, Dong-Jin;Cho, Tae-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.113-119
    • /
    • 2016
  • Wireless sensor networks are vulnerable to an adversary due to scarce resources and wireless communication. An adversary can compromise a sensor node and launch a variety of attacks such as false report injection attacks. This attack may cause monetary damage resulting in energy drain by forwarding the false reports and false alarms at the base station. In order to address this problem, a number of en-route filtering schemes has been proposed. Notably, a dynamic en-route filtering scheme can save energy by filtering of the false report. In the key dissemination phase of the existing scheme, the nodes closer to the source node may not have matching keys to detect the false report. Therefore, continuous attacks may result in unnecessary energy wastage. In this paper, we propose a key re-distribution scheme to solve this issue. The proposed scheme early detects the false report injection attacks using initially assigned secret keys in the phase of the key pre-distribution. The experimental results demonstrate the validity of our scheme with energy efficiency of up to 26.63% and filtering capacity up to 15.92% as compared to the existing scheme.