• Title/Summary/Keyword: Draft Control

Search Result 150, Processing Time 0.03 seconds

A study on Setting up Safety Criteria of Railway Signalling System Using FTA(Fault Tree Analysis) (FTA(Fault Tree Analysis)를 이용한 철도신호설비 안전기준대상 선정에 관한 연구)

  • Yoon, Yong-Ki;Jeong, Rag-Gyo;Kim, Yong-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.671-675
    • /
    • 2008
  • Railway signal system is responsible for the safety operation of railway and performs vital functions as safe space control, route control and etc. These functions prevent collision accidents between trains and derailment accidents of trains. However, these accidents are occurred by some causes. It is necessary to analysis hazards, hazard frequency and risk contribution. And railway signal system must make practical application of the analysis results. This paper includes analysis results of railway accident data by FTA(Fault Tree Analysis) and hazards. Railway signal system must consider these hazards. This paper used the railway accident data of RSSB(Railway Safety & Standard Board) of UK. We will use the FTA result to set up a draft of safety criteria of railway signal system.

  • PDF

Draft Genome Sequence of Mycobacterium abscessus Treated with a Fluoroquinolone in a Time-Dependent Manner

  • Du-Gyeong Han;Ji-A Jeong;Sung-Kyoung Lee;Seong-Han Kim;Se-Mi Jeon
    • Microbiology and Biotechnology Letters
    • /
    • v.52 no.2
    • /
    • pp.211-214
    • /
    • 2024
  • This study aimed to confirm the induction of resistance to other drug classes by treating Mycobacterium abscessus with moxifloxacin, a fluoroquinolone used for treating nontuberculous mycobacteria infection, and to obtain genetic data for improving treatment. The reads were assembled and analyzed using reference strain sequence data, and the whole-genome and transcriptome sequences of four strains (MD2, MD4, MD6, and MD8) were reported. Antibiotic resistance was not induced by moxifloxacin treatment; however, transcriptomic analysis revealed that the expression of genes responding to stress was upregulated.

Development of a Simulation Training Simulator using KEPS (시뮬레이터 연계용 교육, 훈련 Mimic Board 시스템 개발)

  • Cha, S.T.;Kim, T.K.;Choi, J.H.;Kim, C.K.;Lee, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.68-69
    • /
    • 2006
  • A new type of simulation training system for power system operation is presented in this paper It is based on transmission mimic board, double screen PC, mimic control panel, and real-time digital simulator, KEPS. The operating simulation includes the simulations of the control panel interface and the simulator. The mimic board displays transmission network summary information using a software view of the hardware based mimic board. The symbols, numbers and colors layout exactly match those of the KEPS draft case to provide operators a familiar and effective starting point. This paper describes the development of an innovative training system, utilizing the benefits of 3 dimension visualization s/w and communication-control s/w to create the appropriate operational environment and allow simulation of various power system operations without the restrictions of other training methods. Experiences gained in developing concepts and meeting considerable s/w challenges are outlined, and the potential of the simulator for future operations training discussed.

  • PDF

Method for Power control of Wired and Wireless linkage Sensor Network for Low-power Wireless network (저전력 무선 네트워크를 위한 유무선 연동 센서 네트워크의 전력 제어 방법)

  • Lee, Kyung-Sook;Kim, Hyun-Deok
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2012
  • In this paper, using a new low-power consumption method for ZigBee device, which consume low-power using an output power control algorithm through RSSI monitoring as interlocking wireless network using ZigBee which has advantages of a low-power consumption, a low-cost, a compatibility and a draft international standardization enacted by IEEE and ZigBee Alliance, with wired network using built coaxial cable to overcome the disadvantage of the existing wireless sensor network, is proposed. Effectiveness of the output power control algorithm through RSSI monitoring has been verified by experimentation for more optimized low-power consumption.

(A) Study on Contracting Parties' Obligations in International Leasing Agreements - Focus on Draft Common Frame of Reference(DCFR) - (국제리스계약상 당사자의 의무에 관한 소고 - DCFR(유럽계약법 공통참조기준 초안)을 중심으로 -)

  • Oh, Won Suk;Choi, Young Joo
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.63
    • /
    • pp.111-132
    • /
    • 2014
  • This paper analyzed the obligations of the parties entering into an international leasing agreements, focusing on the Draft Common Frame of Reference (DCFR) Book IV, Part B. The lessor's obligations are as follows. i) The lessor must deliver goods to the lessee by the due date of delivery so that the lessee can use the goods on the starting date of the lease agreement. ii) The lessor must conform with the contract so that the goods meet the purpose of the contract at the start of the lease agreement and throughout the period of the lease agreement. iii) If the lessee returns the goods upon the termination of the lease agreement, the lessor must cooperate with the lessee. The lessee's obligations are as follows. i) The lessee must pay rent, which is the most critical obligation of the lessee. ii) The lessee must cooperate with the lessor so that the lessor can perform the obligation to deliver the goods and accept the goods of which the lessee shall take control. iii) The lessee shall perform fiduciary duties while it uses and makes profits from the goods, and when the lessor cannot take any measure to protect the object, the lessee must prevent damage. Further, if the lessor pays expenses that are not considered necessary expenses, the lessor may not be reimbursed and must accept the goods after delivery to preserve them. iv) The lessee must give notice to the lessor if there is a possibility that a third party can claim rights to goods or infringe upon the lessor's ownership while using the goods. v) At the end of the lease period, the lessee must return the goods to the lessor.

  • PDF

An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses (공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1523-1528
    • /
    • 2008
  • In this study, the ventilation system of connection passage and elevator hall of underground parking lot in apartment houses is investigated to extract the data for the installation and the application by the experimentation. In case of the elevator hall, actual air exchange rate is predicted fivefold higher than air exchange rate by infiltration and exfiltration. Ventilation system is installed good by supply air and return air. As the next best thing, it is installed by supply air because of IAQ control. The temperature of connection passage and elevator hall uniformly with $7{\sim}8^{\circ}C$, is maintained even if the operating condition of ventilation system is different. Therefore, the installation of the preheater, which is installed at the inlet of ventilation system for the cold draft in winter, is not essential in southern area of Korea.

An Analysis of Perceptions by Road Construction Engineers on ICEC Framework at the time of System Transition, from Responsibility Supervision to Construction Management (II) - Focused on CM Terminology & ICEC Coordination - (책임감리가 건설사업관리(CM)로 전환시 도입된 역량지수(ICEC)에 대한 도로건설기술자들의 인식 분석(II) - CM 용어와 ICEC 조정을 중심으로 -)

  • Park, Hyo-Sung;Kim, Nak-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.1357-1366
    • /
    • 2015
  • This study (II) aims to draw up the future-oriented construction policy recommendations based on the outcomes as a result of a broad research and conducting questionnaire surveys on the arguable issues raised by construction engineers for roads and bridges in the course of previous study (I) implementation. As for the question of "The term 'Construction Management (CM)' which currently is defined in two (2) ways", 45% of respondents have answered that two (2) different types of CM should be unified into one (1) CM type as is the case in most advanced countries. About the question of "The ways to educate the CM professionals", many respondents have preferred to acquire CM professional certificate after receiving education for a certain period of time from private CM training institutions. As for the question of The revised draft that the ICEC grade of special engineers for design, construction and quality control areas shall be "more than 78 points from a more than 75 points by the original draft." 52% of respondents preferred to maintain the original draft. About the question of "The reason why the CM system has not been working well yet." 62% of respondents have answered that the staff members who are in charge of handling public project procurements are concerned about the fact that their roles (or activities) might be deprived as a result of CM adoption. In order for the CM system to be activated, based on the notion that the construction projects must be out soured, the reshuffle of the headquarter organization of Ministry of Land, Infrastructure and Transportation (MLIT) should be preceded.

Effect Analysis of Tillage Depth on Rotavator Shaft Load Using the Discrete Element Method (이산요소법을 활용한 경심이 로타리 작업기의 경운날 축 부하에 미치는 영향 분석)

  • Bo Min Bae;Dae Wi Jung;Dong Hyung Ryu;Jang Hyeon An;Se O Choi;Yeon Soo Kim;Sang Dae Lee;Seung Je Cho
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.115-122
    • /
    • 2023
  • This study utilized a discrete element method (DEM) simulation, as one of the virtual field trials, to predict the impact of tillage depth on the rotary blade shaft during rotavator tilling. The virtual field for the simulation was generated according to soil properties observed in an actual field. Following the generation of particles for the virtual field, a sequence of calibration steps followed to align the mechanical properties more closely with those of real soil. Calibration was conducted with a focus on bulk density and shear torque, resulting in calibration errors of just 0.02% for bulk density and 0.52% for shear torque. The prediction of the load on a rotary tiller's blade shaft involved a three-pronged approach, considering shaft torque, draft force, and vertical force. In terms of shaft torque, the values exhibited significant increases of 42.34% and 36.91% for every 5-centimeter increment in tillage depth. Similarly, the vertical force saw substantial growth by 40.41% and 36.08% for every 5-centimeter increment. In contrast, the variation in draft force based on tillage depth was comparatively lower at 18.49% and 0.96%, indicating that the effect of tillage depth on draft force was less pronounced than its impact on shaft torque and vertical force. From a perspective of agricultural machinery research, this study provides valuable insights into the DEM soil modeling process, accounting for changes in soil properties with varying tillage depths. These findings are expected to be instrumental in future agricultural machinery design studies.

Energy Saving with Conversion Speed Drive of Cooling Tower Fans

  • Burapanonthachai, Araya;Chaikla, Amphawan;Trisuwannawat, Thanit;Julsereewong, Prasit;Chansangsuk, Dumri
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1017-1022
    • /
    • 2004
  • This paper presents the conversion speed drive of the cooling tower fans from constant to variable speed. The speed of fan is adjusted using variable speed drives. Since the ambient temperature of cooling tower is varied seasonally, an economic evaluation was performed to determine the potential annual savings. The performances of the proposed technique were observed using cooling tower fans of chemical plant in Thailand as an illustrative case study. The experimental results demonstrating the energy savings fork cooling process and some economic benefits are obtained.

  • PDF

A Korean Food Safety Management System(FSMS) Based on the Premises of ISO 22000 (ISO 22000 국제규격 제정에 따른 한국형 식품안전경영시스템(FSMS) 구축모델과 적용방안)

  • Moon, Jae-Sung;Yoo, Wang-Jin;Lee, Cheol-Gyu
    • Journal of Korean Society for Quality Management
    • /
    • v.33 no.3
    • /
    • pp.41-46
    • /
    • 2005
  • The production, processing, sale and service of food materials are not subject to attainment via a single country. In accordance with internationalization of the world, issues related to food safety have emerged as critical international concerns and they are closely associated with the health and interest of domestic consumers, producers, manufacturers, and distributors. As a third party certification standards, ISO 22000 is in progress International Organization for Standardization(ISO) and the Draft International Standard(DIS) has already been presented on December 2004. The purpose of this study is to analyze the international standards, guidelines and legislation in regard of Food Safety Management System(FSMS) including ISO 9001, Hazard Analysis Critical Control Point(HACCP) and Product Liability(PL) so as to present Korean-model Food Safety Management System requirements and system establishment model.