• 제목/요약/키워드: Down conductor

검색결과 40건 처리시간 0.027초

A Study on the Impedance Calculation by using Equivalent Model in Catenary System

  • Kim, Min-Kyu;Kim, Min-Seok;Kim, Dae-Hwan;Lee, Jong-Woo
    • International Journal of Railway
    • /
    • 제3권2호
    • /
    • pp.46-53
    • /
    • 2010
  • Electric railroad systems consist of rolling stock, track, signal and catenary system. In the catenary system, one of the most important factors is the impedance according to the design and characteristic. Before the catenary system is designed, the impedance should be precedently researched. The railroad catenary system is complex system which is composed by five conductors. The five conductors classify up and down feeders, up and down contact wire group, rail group. Therefore, we should compose the catenary system of the equivalent five-conductors model. In this paper, we suggest a geometrical model and a equivalent conductor model by using geometric mean radius of five conductors in the catenary system. Also, we calculate demanded parameter values in the model. By using those, line constants of five conductors are analyzed by applying the equivalent method called as the condensed joint matrix.

  • PDF

철근콘크리트 아파트의 철근구조체에 대한 전기적 연속성 평가 (Evaluation of Steelwork Continuity within Reinforced Concrete Apartment Structures)

  • 이기홍;이택섭;김언석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • This paper conducted to evaluate electrical continuity of steelworks within reinforced concrete apartment structures as the down conductor in external lightning protection system. The reinforcing bars in reinforced concrete structures can be used as the down conductor when their overall electrical resistance is not greater than the resistance value of 0.2 ohm between the uppermost part and the ground level. According to the results of electrical resistances measured by 4-terminal low resistance measurements, the steelworks in reinforced concretes structures exhibited the electrical continuity with low electrical resistance.

  • PDF

철근콘크리트 구조물 내의 철근을 활용한 피뢰설비 인하도선의 설치방법에 관한 연구 (A Study on the Installation Method of Down Conductors of the Lightning Protection System, using Rebar in Reinforced Concrete Structures)

  • 이영철;이주철
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.101-107
    • /
    • 2013
  • IEC Standards on lightning protection system specify the use of natural components as down conductors. This paper provides an analysis of problems revealed from our field investigation and survey conducted for the relevant experts in the construction site where natural components are used as down conductors. It also considers a suitable condition for installing natural components as down conductors in accordance with the latest version of the standard. As a result, when rebars of reinforced concrete are used as down conductors, vertical bars consisting of rebars of which thickness is not less than D13($127mm^2$) should be connected by welding, clamps or bound joints, using appropriate connection components conforming to IEC Standards. The lashed joints, however, shall not be applied for down conductors.

전기도금 롤의 형상 측정시스템 개발 (Development of a profile measuring system for conductor roll)

  • 최용준;전승배;이응석;김효성;장지수
    • 대한기계학회논문집A
    • /
    • 제21권10호
    • /
    • pp.1730-1741
    • /
    • 1997
  • In this paper, we developed a surface profile measuring system and a profile measuring software for EGL conductor roll. For the profilemeter, we designed a linear guided control system with Laser displacement sensors and developed a 3-dimensional software. Additionally, the AC motor and AC motor driver were used to control the precise position of linear guide system. The measuring principle of the Laser sensor is optical triangulation method. Also, two Laser sensors were used to remove the disturbance and vibration effects of the linear guide system.

선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성 (Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

뇌격전류 측정의 정확도에 영향을 미치는 요인 (Factors Affected the Accuracy of Lightning Current Measuring System)

  • 이복희;장근철;강성만;엄주홍;정길조;심응보;우정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF

Coated Conductor에서의 퀜치 거동 (Quench Development in Coated Conductors)

  • 김혜림;박충렬;임성우;유승덕;오성용;현옥배
    • Progress in Superconductivity
    • /
    • 제10권2호
    • /
    • pp.149-154
    • /
    • 2009
  • We measured and analyzed the quench development in coated conductor(CC) tapes. The CC was grown on hastelloy substrates and has an Ag protection layer. The tapes were subjected to simulated AC fault currents for quench development measurement. They were immersed in liquid nitrogen during the experiment. The quench resistance increased rapidly first, and the increase slowed down afterwards. It increased linearly with applied voltage at lower voltages, and depended less strongly on applied voltage at higher voltages. The resistance was compared with that of Au/YBCO films grown on sapphire substrates, and found to increase more monotonously than the latter. Data were analyzed quantitatively with the concept of heat transfer within the tape and the surrounding liquid nitrogen. A heat balance equation was derived and solved, taking into consideration temperature dependence of thermal parameters of the tapes. Solutions, together with values of thermal parameters taken from the literature, explained the data well. Cooling by liquid nitrogen affected the quench development considerably at lower applied voltages. Dependence on applied voltages could be also understood quantitatively.

  • PDF

2차원 MT(Magneto-Telluric)모델링을 이용한 지자기 수직탐사(Geomagnetic Depth Sounding)에서의 차이 지시자의 연구 (A study on the Difference Arrow of GDS (Geomagnetic Depth Sounding) Survey using 2-D MT (Magneto-Telluric) Modeling)

  • 양준모;오석훈;이덕기;윤용훈
    • 자원환경지질
    • /
    • 제35권6호
    • /
    • pp.567-573
    • /
    • 2002
  • 2차원 MT모델링을 수행하여 지자기 수직탐사(GDS)에서의 차이 지시자의 유용성을 조사하였다. 해양과 육지에 위치하는 전도체의 전자기적인 상호 결합 정도는 차이 지시자의 유용성을 판단하는 기준으로서 본 연구에서는 해양과 전도체의 공간적인 위치와 주기에 따른 상호 결합을 조사하였다. 전도체가 지표에 존재하는 경우 해양에서 충분히 떨어져 있거나 사용된 주기가 장주기일 때 차이 지시자가 유용하였고, 전도체가 심부에 매몰된 경우에는 상호 결합이 약해 전 주기에서 차이 지시자가 물리적인 의미를 가졌다. 그러나 전도체가 지표로부터 심부까지 확장되어 있는 경우 상호 결합이 장주기까지 강하게 영향을 미쳐 차이 지시자의 유용성을 확신할 수 없다. 따라서 획득된 유도 지시자로 부터 해양처럼 이미 알고 있는 전도체의 효과를 제거하기 위해서는 수치 모델링을 통한 전도체 간의 상호 결합에 대한 정보가 요구되며 상호 결합이 큰 경우 차이 지시자의 해석은 정확하지 않으므로 주의해야한다.

건축물기초 접지극의 비교 분석에 관한 연구 (Research for a comparison an analysis of grounding electrode in the Foundation of building)

  • 김성삼;김주찬;이충식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 2005
  • In this paper, The experiment is performed for using reinforced building of foundation as a down conductor and a substitutional earth electrode. It is shown that earth resistance is influenced by mortar block resistance and concrete resistance more than the change of the resistance which is about steel reinforcing volume in all of the mortar block model and concrete block model.

  • PDF

도체 수밀형 전력케이블의 가교잔사 가스에 의한 직선접속재 부풀음 현상 방지 대책 (The solution for preventing the expansion of cable joint caused by methane($CH_4$) gas to Water proof type of power cable)

  • 김종원;이기수;백흠수;최봉남;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2020-2022
    • /
    • 2000
  • The cross-linked polyethylene(herein after XLPE) insulated power cable emit the methane($CH_4$)gas in the course of chemical cross-linking process. The general stranded conductor easily discharge this methane gas through the gap of each stranded wires. But the special stranded conductor that filled with semi-conducting rubber compound to prevent water penetration which is applied to water proof type of cable(22.9kV CN/CV-W), disturb the methane gas emission. The pre-mold type cable joint shall be expanded gradually by emit of gas left in XLPE insulation. For example, sometimes the corona problem outbreak on a new power distribution line, resulted from the gap between the sleeve and semi-conductive layer of cable joint. If above mentioned problem especially happened on the way of operating. We have to shut down the line and try to discharge the methane gas in cable joint. In this point, we would like to explain the mechanism of methane gas & cable joint and our test result briefly. At last, we are pleased to introduce the solution for preventing reoccurrence of this problem.

  • PDF