• 제목/요약/키워드: Double-Core

검색결과 323건 처리시간 0.027초

Terfenadine-pseudoephedrine HCl의 이중정 및 유핵정의 비교 용출시험 (Comparative Dissolution test of Terfenadine-Pseudoephedrine HCl Double-layered and Core Tablet)

  • 최한곤
    • Journal of Pharmaceutical Investigation
    • /
    • 제27권3호
    • /
    • pp.213-217
    • /
    • 1997
  • The present sustained-release terfenadine-pseudoephedrine HCl dosage form was the core tablet composed of outer (fast-release) layer containing 60 mg of terfenadine and l0mg of pseudoephedrine HCl, and inner (sustained-release) layer containing 110 mg of pseudoephedrine HCl. The purpose of this study was to investigate the possibility of formulating the terfenadine-pseudoephedrine HCl double-layered tablet which was bioequivalent to the core tablet. Its sustained-release and fast-release layer were formulated with disintegrating agents and polymers, respectively, varying with their kinds and amounts. The comparative dissolution test of double-layered and core tablet was carried out at pH 1.2, 4.0 and 6.8, leading to select composite of double-layered tablet whose dissolution pattern was similar to that of core tablet. It was composed of fast-release layer containing 60mg of terfenadine. 10 mg of pseudoephedrine HCl, sodium bicarbonate, microcrystalline cellulose and sodium starch glycolate, and sustained-release layer containing 110 mg of pseudoephedrine HCl and ethylcellulose/hydroxypropyl methylcellulose) (110/30 mg/tablet).

  • PDF

A simple Model for Separation of the Tsushima Current Stream Core by the Tsushima Island: a small viscosity limit

  • Seung, Young-Ho
    • Journal of the korean society of oceanography
    • /
    • 제38권2호
    • /
    • pp.45-51
    • /
    • 2003
  • Recent observations reveal that the Tsushima Current has a double-cored structure downstream of the Tsushima Island. To explain this, a simple analytical model is proposed based on the assumption of small lateral eddy viscosity. This model suggests that an otherwise uniform current becomes to have a stream core immediately after it enters a channel due to the action of lateral friction. The core is initially broad but becomes sharper downstream. The speed at which the core develops depends on the intensity of lateral eddy viscosity. Likewise, a single-cored stream changes rapidly to a double-cored stream when it passes through an island located in the center of the channel. When the stream leaves the island behind, the reverse process from the double-to single-cored structures takes place. In this case, however, the double-cored structure is retained for a significant distance from the island. Overall, this model suggests that the double-cored structure of the Tsushima Current observed downstream of the Tsushima Island Is created by the lateral friction exerted by the Tsushima Island.

대심도 연약지반 개량을 위한 이중코어 PBD 성능연구 (A Study on Performance of Double-Core PBD for Improving Thick Reclaimed Ground)

  • 양정훈;홍성진;이우진;최항석;김형섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.281-292
    • /
    • 2008
  • Prefabricated Board Drains (PBDs) recently become more widely used than conventional sand drains in improving soft ground because the PBD is more time and cost effective. The performance of PBDs is affected by disturbance in the adjacent soil formation during inserting mandrels, the intrusion of fine particles into filter fabric, and necking of the drain by excessive lateral pressure especially occurring in very deep clay formation such as the Busan New Port site. In this study, the PBD with double-core is introduced, which seems to overcome the shortcomings of usual single-core PBDs. An in-situ test program was established in the Busan New Port site, in which a set of the double-core PBDs and the single-core PBDs was installed to compare the efficiency of each of the drains. The discharge capacity of the double-core and the single-core PBDs was compared for various confining pressures in the modified Delft test and the chamber test. A series of CRS consolidation tests was performed in order to obtain profiles of void ratio-effective stress and void ratio-permeability relationships in the Busan New Port site that are used as input date in performing a numerical program ILLICON. The numerically simulated settlements of ground surface in the test site are in good agreement with those of in-situ measurements. In addition, the performance of the double-core and single-core PBDs has been experimentally and numerically compared in this paper.

  • PDF

플라이휠 에너지 저장 시스템용 양측식 영구자석 동기 전동/발전기의 착자 형태에 따른 특성 비교 (Characteristic comparison of double-side PMSM/G according to magnetization pattern for flywheel energy storage system)

  • 장석명;최지환;유대준;성소영;한상철;이정필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1021-1022
    • /
    • 2011
  • This paper presents the double side PM synchronous motor/generator for core loss reduction in flywheel energy storage system. The use of double PM rotor causes the elimination of core loss in no-load state of machine. Because flywheel rotational speed is reduced by core loss, double PM rotor is very effective in flywheel system. This paper suggests two types of double side PM rotor, Halbach magnetized array and parallel magnetized array. And characteristic comparison according to thickness of rotor back core is performed.

  • PDF

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

스퍼터링 방법으로 증착된 하층 NiFe 코어를 갖는 박막인덕터의 CMOS 집적화 공정 (Fully CMOS-compatible Process Integration of Thin film Inductor with a Sputtered Bottom NiFe Core)

  • 박일용;김상기;구진근;노태문;이대우;김종대
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.138-143
    • /
    • 2003
  • A double spiral thin-film inductor with a NiFe magnetic core is integrated with DC-DC converter IC. The NiFe core is deposited on a polyimide film as the thinckness of NiFe is 2.5~3.5 ${\mu}$m. Then, copper conductor line is deposited on the NiFe core with double spiral structure. Process integration is performed by sequential processes of etching the polyimide film deposited both top and bottom of the NiFe core and electroplation copper conductor line from exposed metal pad of the DC-DC converter IC. Process integration is simplified by elimination planarization process for top core because the proposed thin-film inductor has a bottom NiFe core only. Inductor of the fabricated monolithic DC-DC converter IC is 0.53 ${\mu}$H when the area of converter IC and thin-film inductor are 5X5$\textrm{mm}^2$ and 3.5X2.5$\textrm{mm}^2$, respectively. The efficiency is 72% when input voltage and output voltage are 3.5 V and 6 V, respectively at the operation frequency of 8 MHz.

편광에 무관한 매우 짧은 결합 길이를 가지는 새로운 수직 방향성 결합기 (A novel vertical directional coupler with polarization independent very short coupling lengths)

  • 정병민;김부균
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.359-364
    • /
    • 2003
  • 편광에 따른 성능 변화가 작은 deep-ridge 도파관 구조에 제작이 용이한 double-sided 프로세스를 이용하여 구현할 수 있는 편광에 무관한 매우 짧은 결합 길이를 가지는 double-sided deep-ridge 도파관 구조를 가지는 새로운 수직 방향성 결합기를 제안하고 여러 가지 구조 파라미터들이 결합길이에 미치는 영향에 대하여 연구하였다. 도파관 폭의 변화에 대한 결합길이의 변화는 코어 두께의 변화에 대한 결합길이의 변화보다 작게 나타나는 것을 볼 수 있었다. 내부 클래딩 영역의 두께가 감소할수록, 코어 두께가 감소할수록 결합 길이가 감소함을 볼 수 있었다. 또한 같은 코어 두께에 대해서는 내부 클래딩 영역의 두께가 감소할수록, 같은 내부 클래딩 영역의 두께에 대해서는 코어 두께가 감소할수록 편광에 관계없이 결합 길이가 같아지는 도파관 폭이 작아짐을 볼 수 있었다.

단일 및 이중 코어 PBD에 의한 대심도 연약지반 개량 효과에 관한 비교연구 (Comparison on the Performance of Soil Improvement in Thick Soft Ground Using Single-Core and Double-Core PBD)

  • 양정훈;홍성진;김형섭;이우진;최항석
    • 한국지반공학회논문집
    • /
    • 제25권8호
    • /
    • pp.33-45
    • /
    • 2009
  • 단일코어 연직 배수재 공법은 현재까지 폭넓게 사용되는 연약지반 개량공법이다. 그러나 얇은 플라스틱 보드 형태의 PBD 구조로 인해 압밀 도중 큰 횡 방향 토압과 이에 따른 necking 현상이 발생하고 이는 PBD의 통수능을 감소시킨다. 본 연구 대상인 부산신항만 조성 공사현장은 대심도의 연약지반으로서 PBD 설치 시, 큰 횡 방향 토압에 의한 통수능 감소를 예상되어 통수능 감소현상을 극복하기 위하여 이중코어 PBD를 도입, 시공하고, 기존 형태의 단일코어 PBD를 동시에 설치한 후, 현장에서의 배수재 성능을 비교분석하였다. 실내실험으로는 개량 델프트 실험을 수행하여 연직배수재의 통수능을 측정하고, 현장에서 채취한 시료를 이용해 기본 물성실험 및 CRS 압밀시험을 수행하여 수치 해석 프로그램인 ILLICON에 적용하여 침하거동 양상을 파악하였다. 개량 델프트 실험에서는 이중코어 PBD의 통수능이 단일코어 PBD보다 높게 측정되었으나, 현장 계측 및 수치해석에서는 차이가 나타나지 않았다. 이는 일발전인 대심도 지반에서 압밀시 발생되는 물의 배수량은 상대적으로 작은 단일코어 PBD의 통수능 범위 보다도 작기 때문에 실제 현장에서는 단일코어 PBD와 이중코어 PBD의 성능차이가 없음을 확인하였다.

Double bonded Cooper-Naghdi micro sandwich cylindrical shells with porous core and CNTRC face sheets: Wave propagation solution

  • Yazdani, Raziye;Mohammadimehr, Mehdi
    • Computers and Concrete
    • /
    • 제24권6호
    • /
    • pp.499-511
    • /
    • 2019
  • In this paper, wave propagation of double-bonded Cooper-Naghdi micro sandwich cylindrical shells with porous core and carbon nanotube reinforced composite (CNTRC) face sheets are investigated subjected to multi-physical loadings with temperature dependent material properties. The governing equations of motion are derived by Hamilton's principle. Then, the influences of various parameters such as wave number, CNT volume fraction, temperature change, Skempton coefficient, material length scale parameter, porosity coefficient on the phase velocity of double-bonded micro sandwich shell are taken into account. It is seen that by increasing of Skempton coefficient, the phase velocity decreases for higher wave number and the results become approximately the constant. Also, by increasing of the material length scale parameter, the cut of frequency increases, because the stiffness of micro structure increases. The obtained results for this article can be used to detect, locate and quantify crack.

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.