• Title/Summary/Keyword: Double noise exposure

Search Result 10, Processing Time 0.026 seconds

Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

  • Song, Boram;Kim, Changsoo;Kim, Junwoo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.160-169
    • /
    • 2021
  • Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.

Hand-Arm Vibration and Noise Levels of Double-Hammer Type and Oil-Pulse Type Impact Wrenches in Automobile Assembly Lines (자동차 조립라인에서 이중-헴머형(Double-hammer type) 임펙트 렌치와 오일-펄스형(Oil-pulse type)임펙트 렌치 에어공구의 국소진동가속도 및 소음수준)

  • Jeung, Jae-Yeal;Kim, Jung-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.147-159
    • /
    • 1995
  • This study was conducted to introduce fundamental data of hand-arm vibration and noise exposure levels with impact wrenches(double-hammer impact wrenches and oil-pulse impact wrenches) used in automobile assembly lines considering the process variables and tool variables. In studing, products per day, required time screwing the bolts or nuts per bolts or nut were considered as process variables, and capacity of bolts or nuts, air consumptions per minute, tool weights, RPM were considered as tool variables. Hand-arm vibration levels of 3 axis in each hand were measured using the instruments compling with ISO/DIS 5349 and noise levels were measured using a noise logging dosimeter. The results were as follows : 1. Required time to screwing the bolt or nut by oil-pulse impact wrenches is shorter than double-hammer impact wrenches but total daily exposure time of oil-pulse impact wrenches was higher than double-hammer impact wrenches because the number of bolts or nuts per cycle was many. 2. Oil-pulse impact wrenches have been used to screwing the large bolt or nut in comparing with double-hammer impact wrenches and required time to screwing the bolts or nuts were shorter than double-hammer impact wrenches because oil-pulse impact wrenches were using high RPM and large air consumption per minute. Noise level of oil-pulse impact wrenches was 8 dB(A) lower than double-hammer impact wrenches. 3. Dominant hand-arm vibration levels of double-hammer impact wrenches in each hand were $8.24m/sec^2$ of Zh axis in right hand and $9.60m/sec^2$ of Xh axis in left hand. Dominant hand-arm vibration level of oil-pulse impact wrenches in each hand was $2.59m/sec^2$ of Xh axis in right hand and $3.23m/sec^2$ of Yh axis in left hand. 4. In double-hammer impact wrenches, corresponding hand-arm vibration levels of Xh, Yh, Zh axis in left hand were higher than hand-arm vibration levels of right hand in 3 axis. In oil-pulse impact wrenches, Xh axis of right, Yh axis of left, Zh axis of left were higher than the corresponding hand-arm vibration levels of Xh, Yh, Zh axis in right and left hand. 5. Correlation coefficients among Xh, Yh. Zh axis of right and left hand hand-arm vibration levels in double-hammer impact wrenches and oil-pulse impact wrenches were commonly high in Yh axis and correlation coefficients of Yh axis in double-hammer impact wrenches and oil-pulse impact wrenches were 0.76 and 0.86,respectively. 6. As a measure repetitiveness, plotting total daily exposure time with the number of bolts or nut per cycle, direct correlation was shown between repetitiveness and hand-arn vibration exposure, and correlation coefficient between the number of bolts or nut per cycle and total daily exposure time in double-hammer impact wrenches, oil-pulse impact wrenches were 0.84 and 0.50, respectively. 7. Considering the total acceleration level and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption in right hand, and bolt or nut capacity in left hand were commonly the variable that explainability was high. Considering the noise and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption per minute was commonly the variable that explainability was high.

  • PDF

Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry (홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.530-535
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at $Ra = 6.35{\times}10^6$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful for analyzing the temperature field variations of unsteady thermal fluid flows.

  • PDF

Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry (홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1624-1631
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at Ra = 6.35 $\times$ 10$^{6}$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful fur analyzing the temperature field variations of unsteady thermal fluid flows.

A Study on the Vibration Characteristics by the Change of Impact Load Direction in the Collecting Plates of Electrostatic Precipitator (충결하중의 방향에 따른 정전집진기 집진판의 진동 특성 연구)

  • 나종문;이기백;양장식
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.247-256
    • /
    • 1995
  • In this paper, double exposure holographic interferometry using ruby pulse laser is formed in order to investigate the propagation of transient waves. The vibration characteristics according to the change of impact load direction, i.e., impacted in the shear direction and in the normal direction are analyzed. It was observed that the macroscopic trends of transient wave generation and propagation in the assembly of precipitator plates were almost similar regardless of the change of impact load direction. But the propagation and mixing of transient wave was advanced relatively slowly when impacted in the normal direction.

  • PDF

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.

Changes of Acoustic Reflex Thresholds and Speech-In-Noise Perception Using Personal Listening Device Under Subway Interior Noise (지하철 실내 소음 하에서 음향기기 사용에 따른 음향반사역치와 소음 속 어음인지 변화)

  • Han, Woojae;Chun, Hyungi;Ma, Sunmi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.138-145
    • /
    • 2015
  • Although it is well-known that environmental noise can lead to hearing loss in individuals, the true extent of subway noise effects in the general population remains poorly understood. The purpose of the present study is to see changes of acoustic reflex thresholds and speech perception scores when passengers listen to music presented from their personal listening device in the subway. Forty subjects with normal hearing participated being divided into two groups, experimental and control groups. As a baseline, all subjects were measured by acoustic reflex thresholds in five test frequencies and Korean speech perception in noise (KSPIN) test at 0 and -5 dB SNR. In the experiment, the control group read newspaper or magazine in the subway noise, whereas the experimental group listened to music presented from their smartphone under the subway noise through speakers at 73.45 dBA for 60 min. After completing the experiment, two groups also conducted both acoustic reflex thresholds and KSPIN tests in the same condition as the baseline. The results showed that there was a significant difference of correct percent in speech-in-noise test between experimental and control groups and of that between two signal-to-noise ratios, which means the double noise exposure of 60 min might cause some degradation of speech perception when noise increases compared to only subway noise condition that was not statistically significant difference. We concluded that a risk of some degraded speech perception ability would be expected when passengers have a habit of listening to music in the subway noisy situation for a long duration.

Fabrication of $0.25 \mu\textrm{m}$ P-HEMT for X-band Low Noise Amplifier (X-밴드 저잡음 증폭기용 $0.25 \mu\textrm{m}$ T-형 게이트 P-HEMT 제작)

  • 이강승;정윤하
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.17-20
    • /
    • 2000
  • We have enhanced the yield of 0.25 ${\mu}{\textrm}{m}$ T-gate $Al_{0.25}$G $a_{0.75}$As/I $n_{0.2}$G $a_{0.8}$As P-HEMT using three-layer E-beam lithography process and selective etching process. The three-layer resist structure (PMMA/copolymer/ PMMA=2000 $\AA$/3000 $\AA$/2000 $\AA$) and three developers (Benzene:IPA=1:1,Methanol:IPA =1:1,MIBK:IPA=1:3) were used for fabrication of a wide-head T-gate by the conventional double E-beam exposure technology. Also 1 wt% citric acid: $H_2O$$_2$:N $H_{4}$OH(200m1:4ml:2.2ml) solution were used for uniform gate recess. The etching selectivity of GaAs over $Al_{0.25}$G $a_{0.75}$As is measured to be 80. So these P-HEMT processes can be used in X-band MMIC LNA fabrication.ion.ion.ion.

  • PDF

Vibration Characteristics of the Collecting Plates in Electrostatic Precipitator (정전집진기 집진판의 진동 특성)

  • 나종문;이기백;양장식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.313-317
    • /
    • 1995
  • 최근 환경오염이 심각한 사회문제로 대두됨에 따라 환경오염원을 제거하기 위한 여러 가지의 집진장치가 개발되고 있는데 화력발전소에서는 건식정전집진장치(dry electrostatic precipitator)를 이용하고 있다. 건식정전집진장치는 햄머(hammer) 방식의 충격장치를 설치하여 집진극과 방전극에 충격을 가함으로써 충격력을 극대화시키고 높은 분진박리 효과를 꾀하고 있는데 환경오염원이 되고 있는 집진판의 분진의 분리율을 높이기 위해서는 집진판의 전체 영역에서 분진을 동일하게 떨어뜨릴 수 있는 충격장치가 설계되어야 하는데, 이를 위해서는 충격하중에 따른 집진판의 진동 형태를 정확하게 분석하여야 한다. 본 연구에서는 집진판의 충격하중에 따른 진동의 형태를 분석하기 위해 펄스 레이저를 이용한 2중 노출 홀로그래피 시스템을 구성하였다. 홀로그래픽 간섭계는 이미 오래 전에 개발된 레이저 응용 계측기법으로서 주로 정현적인 진동을 하는 진동체의 진동 현상을 연구하는 데에 많이 사용되어 왔는데 그 기술 개발은 상당한 수준에 있다. 그러나 종래의 기술들은 주로 헬륨-네온(He-Ne)레이저와 같은 연속 레이저(continuous wave laser)를 이용한 기술들인데 최근에는 루비(ruby) 레이저와 같은 펄스 레이저 (pulse laser)를 이용한 기술이 많이 응용되고 있다. 이 펄스 레이저 홀로그래픽 간섭계를 Gottenberg는 응력파에 의해서 발생된 변형을 측정하기 위해 사용하였고 Aprahamian등은 보(beam)와 평판의 굽힘파(bending wave)의 전파 특성 연구에 이용하였다. 그 실험적 결과는 수치적 해석 결과와 비교되어 매우 좋은 일치성을 보였는데 이러한 펄스 레이져 홀로그래픽 간섭계 기법의 주요 장점은 어떠한 특정한 순간에 관찰하고자 하는 시험편의 전체 영역의 파동 전파 형상을 관찰할 수 있다는 것이다. 따라서 본 연구에서는 펄스 레이저를 응용한 2중 노출 홀로그래피법(double exposure holography method)을 이용해서 집진판에 충격하중이 가해졌을 때 발생하는 진동이 발생과 전파 특성을 충격하중의 방향에 따라서 분석하였다.

  • PDF

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.