• 제목/요약/키워드: Double line

Search Result 776, Processing Time 0.028 seconds

Numerical Analysis Approach to Calculate the Damage Degree of the Combat Vehicle (전투차량의 피해 정도를 계산하기 위한 수치해석적 접근법)

  • Cho, A Hyoun;Park, Kang;Kim, Gun In
    • Korean Journal of Computational Design and Engineering
    • /
    • v.22 no.2
    • /
    • pp.101-109
    • /
    • 2017
  • In order to reduce the number of casualties by improving the survivability of the combat vehicle, the vulnerability analysis of the combat vehicle is needed. However, the actual test for the vulnerability analysis requires large experimental space and expensive equipment costs long time and large expense. It is needed to develop a new method that can replace the actual test. In the paper, we suggested a new approach to analyzing the vulnerability using the M&S method instead of the actual test. To analyze the vulnerability, the shot line analysis is performed to find out which part is penetrated by the bullet. The component of the parts is simplified to "Single-Target", "Double-Target", "Air gapped-Target" and can be performed the penetration analysis using the ANSYS Explicit Dynamics. The penetration depth and the residual velocity of the bullet are calculated by analyzing penetration of each part of the combat vehicle. The penetration data calculated the penetration analysis can be used to define the damage level of the combat vehicle. The purpose of this paper is to collect penetration data for various targets and bullets. And "7.62mmAP" is used as the bullet, "7075-T6" is used as a target.

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

Single-Feed, Wideband, Circularly Polarized, Crossed Bowtie Dipole Antenna for Global Navigation Satellite Systems

  • Tran, Huy Hung;Ta, Son Xuat;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.3
    • /
    • pp.299-305
    • /
    • 2014
  • A wideband circularly polarized (CP) antenna with a single feed is proposed for use in global navigation satellite systems. Its primary radiation elements are composed of two orthogonal bowtie dipoles, which are equipped with double-printed vacant-quarter rings to allow direct matching of the antenna to a single $50-{\Omega}$ coaxial line and to produce CP radiation. The crossed bowtie dipole is appropriately incorporated with a planar metallic reflector to produce the desired unidirectional radiation pattern as well as to achieve a wideband characteristic in terms of impedance matching and axial ratio (AR) bandwidths. The designed antenna was fabricated and measured. The prototype antenna with an overall 1.2-GHz frequency size of $0.48{\lambda}_o{\times}0.48{\lambda}_o{\times}0.25{\lambda}_o$ produced a measured ${\mid}S_{11}{\mid}$<-10 dB bandwidth of 1.05-1.79 GHz and a measured 3-dB AR bandwidth of 1.12-1.64 GHz. It also showed right-hand CP radiation with a small gain variation (${\pm}0.3dB$) and high radiation efficiency (>93%) over the operational bandwidth.

Analysis of the Spatial Configuration of Lobby in General Hospital (종합병원 로비의 기능요소에 따른 공간구조 분석)

  • Choi, Inyoung;Park, Heykyung
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.1
    • /
    • pp.134-141
    • /
    • 2017
  • General hospitals in Korea have increased more in size since 2000, and as not only medical service but the quality of the environment also got important, the considerable changes have appeared revolving around the lobbies. This study is a basic research to find a direction of a plan for general hospital lobbies in response to the demands that change. It was examined the current condition of lobbies so as to derive the idea of types of lobbies and of functional elements, and based on the research, it was compared and analyzed in terms of the spatial configuration to draw the characteristics by type. The result of the research is as follows. (1) The lobbies were explored after being classified into four types; the plan(central type/street type) and the elevation(eclectic type/double-story type). (2) The hall and corridor were ranked high in order of importance in the whole spatial configuration, and it has been utilized in various ways. (3) Also, each type differed with the others in its main functional area, regarding traffic line efficiency and spatial intelligibility.

Estimation of Fault Location on Transmission Lines using Current Phasor (전류 페이저를 이용한 송전선로 고장점 추정 알고리즘)

  • Yeo, Sang-Min;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2095-2100
    • /
    • 2009
  • Since most of the Extra High Voltage (EHV) transmission lines are untransposed and multi-circuits, errors are occurred inevitably because of the unbalanced impedances of the lines and so on. Therefore, a distance relaying algorithm applicable to the untransposed multi-circuits transmission lines needs to be developed. The proposed algorithm of fault location estimation in the paper uses the fundamental phasor to reduce the effects of the harmonics. This algorithm also analyzes the second-order difference of the phasor to calculate the traveling times of waves generated by faults. The traveling time of the waves generated by faults is derived from the second-order difference of the phasor. Finally, the distance from the relaying point to the faults is estimated using the traveling times. To analyze the performance of the algorithm, a power system with the EHV untransposed double-circuit transmission lines are modeled and simulated under various fault conditions such as several fault types, fault locations, fault inception angles and fault resistances. The results of the simulations show that the proposed algorithm has the capability to estimate the fault locations quickly and accurately.

The Modeling of inductive power collector for vehicle (차량용 유도전력 집전 장치의 특성해석)

  • Han, K.H.;Lee, B.S.;Kim, D.W.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1610-1612
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the PRT(Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. Also, a model of power collector and parallel winding structure and a model of concentration/decentralization winding are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

The Present State of Wind Turbine Condition Monitoring System (풍력 터빈 상태 감시 시스템 현황)

  • Clark, Timothy J.;Bauer, Richard F.;Rasmussen, James R.;Jeong, J.H.;Lee, B.J.;Lee, C.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.92-97
    • /
    • 2005
  • The $9 billion US global wind energy market is experiencing dramatic growth with installed generating capacity up 500% from 7,600 MW at the end of 1997 to nearly 39,300 MW at the end of 2003. With an average annual increase approaching 32%, wind is the world's fastest growing energy source on a percentage basis, and its growth is forecast to continue a double-digit pace into the next decade 1. While much of this growth is fueled by government decisions that are favorable to 'green' or renewable Power, it is also fueled by advances in wind turbine technology as evidenced by larger, more sophisticated machines. As a result, wind turbines are becoming more established as an economically viable alternative to fossil-fueled power generation. Today, wind 'farms' - consisting of anywhere from a single turbine to as many as several hundred turbines - are an important component of the world's source of electric energy.

  • PDF

A Study on the Plane Rectangular Coordinate in Korea (우리나라 평면직각좌표에 관한 연구)

  • 최재화
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.1 no.2
    • /
    • pp.42-59
    • /
    • 1983
  • This article investigates the situation of the Plane Rectangular Coordinate derived from the Gauss Double Projection whereby the positioning of triangulation point in Korea has been represented on. Analyzing and assessing it have been performed by means of new computational method such as computer programing. On the basis of the results brought about, it is found that a new Plane Rectangular Coordinate as well as map projection and scale factor of geodetic length may be adapted to improve the distortion along the geodetic line on a certain zone of map projection in order to enhance the accuracy and the utility of the practical surveying works. The proposals for this study are as follows; (1) projection: Gauss-Kruger's projection (2) Coordinate system: Plane Rectangular coordinate with 8 origin system (3) Scale factor of geodetic length in origin; $m_0=0.9999$

  • PDF

Anterior Screw Fixation using Herbert Screw for Type II Odontoid Process Fractures

  • Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.345-349
    • /
    • 2005
  • Objective: Anterior screw fixation provides the best anatomical and functional results for type II odontoid process fracture (type II-A, II-N, and II-P) with intact transverse ligament. The purpose of this study is to evaluate the usefulness of the 4.5mm diameter, cannulated Herbert screw in anterior screw fixation. Methods: From Jan. 2003 to Feb. 2004, consecutive 10cases of type II odontoid process fractures were treated with anterior screw fixation using a Herbert screw. The Herbert screw has double threads, with different pitches on the distal and proximal ends. It has no head, so it can be inserted through articular cartilage and buried below bone surface. It was originally developed for treating scaphoid fractures. Results: There were 8male and 2female patients whose ages ranged from 15 to 67years (mean 42.1years). The fracture type was type II-A in 4patients, II-N in 3 patients, and II-P in 3 patients. The fracture line was oblique downward and backward in 6cases, oblique downward and forward in 1 case, and horizontal in 3cases. The range of follow-up was 5 to 18months (mean 12months). Bone fusions were achieved in all cases without any instrumental failures or postoperative complications. Conclusion: The Herbert screw is very useful in anterior fixation for type II odontoid process fracture. This series showed successful results also in type II-A odontoid fracture when treated with the Herbert screw, but further more studies are required.

Notes on the Endothia Canker of Carpinus laxiflora and its Pathogenic Fungus, Endothia fluens Schw Shear et Stevens (서-나무 위축병(萎縮病)과 그 병원균(病原菌))

  • Kim, Kichung
    • Journal of Korean Society of Forest Science
    • /
    • v.6 no.1
    • /
    • pp.6-10
    • /
    • 1967
  • In the present paper author investigated the symptom, pathogenic fungus and pathogenicity of Endothia canker of Carpinus laxiflora in Korea, and made clear the indistinct discription on its pathogen in the past. 1. The pathogen is identified as Endothia fluens (Schw.) Shear et Stevens. The discription is recorded as follows: Stromata cortical, erumpent, spherical or conical, outer yellowish-brown and inner yellowish, 0.5 to 2.5 mm in diameter; perithecia irregularly embeded in the bottom of stroma, 7 to 23 in a stroma usually spherical to elliptical or irregular, 235 to $370{\mu}$ in diameter, with black slender necks; each neck open the papilliate ostiole to the surface, about 250 to $400{\mu}$ in length; asci clavate or fusoid, colorless, 31.16 to 42.64 by 6.54 to $8.20{\mu}$ in size, average 37.02 by $6.84{\mu}$, with 8 ascospores in double line; ascospores elliptical, ovate or cylindrical, with rounded ends, hyaline, 1-septate, not constrict at the septum, 6.51 to 9.30 by 3.16 to $3.72{\mu}$, average 7.61 by $3.44{\mu}$ in size; pycnidia formed abundantly in stroma. spherical at first but later irregular large cavity by fussing each other; pycnospores oblong or rod-shaped, hyaline, non-septate, 3.8 by $1.9{\mu}$ in size; spore-horn formed abundantly under moist condition. 2. The pathogen is wound parasite invading the hosts through the wound. But after the infection is established, expanding the disease lesion is swiftly vigorus.

  • PDF