Anterior Screw Fixation using Herbert Screw for Type II Odontoid Process Fractures

  • Sung, Joo-Kyung (Department of Neurosurgery, Kyungpook National University School of Medicine)
  • Published : 2005.05.28

Abstract

Objective: Anterior screw fixation provides the best anatomical and functional results for type II odontoid process fracture (type II-A, II-N, and II-P) with intact transverse ligament. The purpose of this study is to evaluate the usefulness of the 4.5mm diameter, cannulated Herbert screw in anterior screw fixation. Methods: From Jan. 2003 to Feb. 2004, consecutive 10cases of type II odontoid process fractures were treated with anterior screw fixation using a Herbert screw. The Herbert screw has double threads, with different pitches on the distal and proximal ends. It has no head, so it can be inserted through articular cartilage and buried below bone surface. It was originally developed for treating scaphoid fractures. Results: There were 8male and 2female patients whose ages ranged from 15 to 67years (mean 42.1years). The fracture type was type II-A in 4patients, II-N in 3 patients, and II-P in 3 patients. The fracture line was oblique downward and backward in 6cases, oblique downward and forward in 1 case, and horizontal in 3cases. The range of follow-up was 5 to 18months (mean 12months). Bone fusions were achieved in all cases without any instrumental failures or postoperative complications. Conclusion: The Herbert screw is very useful in anterior fixation for type II odontoid process fracture. This series showed successful results also in type II-A odontoid fracture when treated with the Herbert screw, but further more studies are required.

Keywords

References

  1. Apfelbaum RI : Anterior screw fixation for odontoid fractures, in Rengachary SS, Wilkins RH(eds) : Neurosurgical Operative Atlas, ed 3. Park Ridge, IL : American Association of Neurological Surgeons, 1992, Vol 2, pp189-199
  2. Apfelbaum RI, Lonser RR, Veres R, Casey A : Direct anterior screw fixation for recent and remote odontoid fractures. J Neurosurg(Spine 2) 93 : 227-236, 2000
  3. Bohler J : Anterior stabilization for acute fractures and nonunions of the dens. J Bone Joint Surg 64A : 18-27, 1982
  4. Borne GM, Bedou GL, Pinaudeau M, Cristino G, Hussein A : Odontoid process fracture osteosynthesis with a direct screw fixation technique in nine consecutive cases. J Neurosurg 68 : 223-226, 1988 https://doi.org/10.3171/jns.1988.68.2.0223
  5. Dunn ME, Seljeskog EL : Experience in the management of odontoid process injuries : an analysis of 128 cases. Neurosurgery 18 : 306-310, 1986 https://doi.org/10.1227/00006123-198603000-00008
  6. Etter C, Coscia M, Jaberg H, Aebi M : Direct anterior screw fixation of dens fractures with a cannulated screw systen. Spine 16(Suppl 3) : S25-S32, 1991 https://doi.org/10.1097/00007632-199103001-00006
  7. Fujii E, Kobayashi K, Hirabayashi K : Treatment in fractures of the odontoid process. Spine 13 : 604-609, 1988 https://doi.org/10.1097/00007632-198813060-00002
  8. Geisler FH, Cheng C, Poka A, Brumback RJ : Anterior screw fixation of posteriorly displaced type II odontoid fractures. Neurosurgery 25 : 30-38, 1989 https://doi.org/10.1227/00006123-198907000-00006
  9. Hadley MN, Browner C, Sonntag VKH : Axis fractures : a comprehensive review of management and treatment in 107 cases. Neurosurgery 17 : 281-290, 1985 https://doi.org/10.1227/00006123-198508000-00006
  10. Hashizume H, Kawakami M, Kawai M, Tamaki T : A clinical case of endoscopically assisted anterior screw fixation for the type II odontoid fracture. Spine 28 : 102-105, 2003 https://doi.org/10.1097/00007632-200303010-00024
  11. Hott JS, Henn JS, Sonntag VKH : A new table-fixed retractor for anterior odontoid screw fixation : technical note. J Neurosurg(Spine 3) 98 : 294-296, 2003 https://doi.org/10.3171/spi.2003.98.3.0294
  12. Jenkins JD, Coric D, Branch CL Jr : A clinical comparison of one- or two-screw odontoid fixation. J Neurosurg 89 : 366-370, 1998 https://doi.org/10.3171/jns.1998.89.3.0366
  13. Kim MJ, Hwang JH, Sung JK, Hwang SK, Hamm IS, Park YM, et al : Anterior screw fixation of type II odontoid fracture. J Korean Neurosurg Soc 29 : 1461-1468, 2000
  14. Lind B, Nordwall A, Sihlbom H : Odontoid fractures treated with halovest. Spine 12 : 173-177, 1987 https://doi.org/10.1097/00007632-198703000-00014
  15. Maiman DJ, Larson SJ : Management of odontoid fractures. Neurosurgery 11 : 471-476, 1982 https://doi.org/10.1227/00006123-198210000-00001
  16. Mc Bride AD, Mukherjee DP, Kruse RN, Albright JA : Anterior screw fixation of type II odontoid fractures : A biomechanical study. Spine 20 : 1855-1859, 1995 https://doi.org/10.1097/00007632-199509000-00001
  17. Montesano PX, Anderson PA, Schlehr F, Thalgott JS, Lowrey G : Odontoid fractures treated by odontoid anterior screw fixation. Spine 16 : 33-37, 1991 https://doi.org/10.1097/00007632-199103001-00007
  18. Morandi X, Hanna A, Brassier G : Anterior screw fixation of odontoid fractures. Surg Neurol 51 : 236-242, 1999 https://doi.org/10.1016/S0090-3019(98)00113-X
  19. Rainov NG, Heidecke V, Burkert W : Direct anterior fixation of odontoid fractures with a hollow spreading screw system. Acta Neurochir(Wien) 138 : 146-153, 1996 https://doi.org/10.1007/BF01411353
  20. Sonntag VK, Dickman CA, Vardiman A : Anterior odontoid screw fixation in Menezes AH, Sonntag VK(eds) : Principles of Spinal Surgery : New York, McGraw-Hill, pp1039-1049, 1996
  21. Subach BR, Morone MA, Haid RW Jr, McLaughlin MR, Rods GR, Comey CH : Management of acute odontoid fractures with single-screw anterior fixation. Neurosurgery 45 : 812-820, 1999 https://doi.org/10.1097/00006123-199910000-00015
  22. Wang GJ, Mabie KN, Whitehill R, Stamp WG : The nonsurgical management of odontoid fractures in adults. Spine 9 : 229-230, 1984 https://doi.org/10.1097/00007632-198404000-00001